Please login if you have access to particular applications.
Deployment Details
Survey: - IN2017_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4425,Licor - CTD 23 - SN 70111,Oxygen CTD 23 - SN 1794,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 23 - SN 4722,Transmissometer - CTD 23 -CST-1735DR
When: 2017-03-21 14:49 to 2017-03-21 18:24 UTC
Where: 46° 43.5' S 141° 56.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number  | 
Pressure |  
Oxygen (µM)  | 
 
Salinity (psu)  | 
 
Nitrate (µM)  | 
 
Temperature (deg C)  | 
 
Orthophosphate (µM)  | 
 
Ammonia (µM)  | 
 
Nitrite (µM)  | 
 
Silicate (µM)  | 
|---|---|---|---|---|---|---|---|---|---|
| 36 | 8.1 | < 0.02 | < 0.02 | 9.39 | 11.55 | 0.72 | 0.09 | 0.18 | 0.45 | 
| 35 | 24.9 | < 0.02 | < 0.02 | 9.40 | 11.54 | 0.72 | 0.09 | 0.18 | 0.44 | 
| 34 | 50.5 | 282.26 | 34.523 | 10.29 | 11.29 | 0.78 | 0.13 | 0.19 | 0.72 | 
| 33 | 75.3 | < 0.02 | < 0.02 | 11.94 | 10.51 | 0.90 | 0.34 | 0.25 | 1.43 | 
| 32 | 98.5 | < 0.02 | < 0.02 | 13.07 | 10.17 | 0.96 | 0.08 | 0.49 | 2.29 | 
| 31 | 124.1 | 264.88 | 34.776 | 13.16 | 10.13 | 0.95 | < 0.02 | 0.02 | 3.31 | 
| 30 | 149.8 | < 0.02 | < 0.02 | 13.50 | 9.90 | 0.97 | < 0.02 | 0.02 | 3.53 | 
| 29 | 176.4 | < 0.02 | < 0.02 | 14.06 | 9.57 | 1.01 | < 0.02 | 0.02 | 3.69 | 
| 28 | 199.8 | 269.66 | 34.685 | 14.25 | 9.49 | 1.02 | < 0.02 | < 0.02 | 3.73 | 
| 27 | 224.8 | < 0.02 | < 0.02 | 14.49 | 9.27 | 1.03 | < 0.02 | < 0.02 | 3.79 | 
| 26 | 249.9 | < 0.02 | < 0.02 | 14.65 | 9.23 | 1.04 | < 0.02 | < 0.02 | 3.81 | 
| 25 | 299 | 272.34 | 34.625 | 14.96 | 9.11 | 1.06 | < 0.02 | < 0.02 | 3.86 | 
| 24 | 351 | < 0.02 | < 0.02 | 14.83 | 9.06 | 1.06 | < 0.02 | < 0.02 | 3.80 | 
| 23 | 399.4 | < 0.02 | < 0.02 | 15.09 | 9.01 | 1.08 | < 0.02 | < 0.02 | 3.86 | 
| 22 | 599.9 | 263.54 | 34.536 | 17.67 | 8.49 | 1.23 | < 0.02 | < 0.02 | 5.33 | 
| 21 | 800.7 | < 0.02 | < 0.02 | 23.80 | 7.25 | 1.61 | < 0.02 | < 0.02 | 11.81 | 
| 20 | 1001.3 | < 0.02 | < 0.02 | 28.71 | 5.73 | 1.94 | < 0.02 | < 0.02 | 22.68 | 
| 19 | 1199.4 | 208.92 | 34.334 | 32.19 | 4.12 | 2.19 | < 0.02 | < 0.02 | 36.51 | 
| 18 | 1300.7 | < 0.02 | < 0.02 | 33.31 | 3.82 | 2.28 | < 0.02 | < 0.02 | 46.60 | 
| 17 | 1400.1 | < 0.02 | < 0.02 | 34.15 | 3.49 | 2.35 | < 0.02 | < 0.02 | 53.09 | 
| 16 | 1599.8 | 174.18 | 34.514 | 35.03 | 3.03 | 2.42 | < 0.02 | < 0.02 | 69.81 | 
| 15 | 1799.2 | < 0.02 | < 0.02 | 34.64 | 2.70 | 2.38 | < 0.02 | < 0.02 | 72.56 | 
| 14 | 2002.1 | < 0.02 | < 0.02 | 34.10 | 2.51 | 2.35 | < 0.02 | < 0.02 | 81.78 | 
| 13 | 2200.5 | 177.35 | 34.691 | 33.55 | 2.39 | 2.31 | < 0.02 | < 0.02 | 86.27 | 
| 12 | 2401.1 | < 0.02 | < 0.02 | 33.04 | 2.27 | 2.28 | < 0.02 | < 0.02 | 90.91 | 
| 11 | 2600.4 | < 0.02 | < 0.02 | 33.31 | 2.12 | 2.31 | < 0.02 | < 0.02 | 100.01 | 
| 10 | 2800 | 183.38 | 34.732 | 33.11 | 2.03 | 2.29 | < 0.02 | < 0.02 | 102.27 | 
| 9 | 2999.6 | < 0.02 | < 0.02 | 31.91 | 1.92 | 2.19 | < 0.02 | < 0.02 | 95.98 | 
| 8 | 3100.7 | < 0.02 | < 0.02 | 31.48 | 1.84 | 2.16 | < 0.02 | < 0.02 | 94.59 | 
| 7 | 3300.3 | 200.62 | 34.738 | 32.10 | 1.66 | 2.21 | < 0.02 | < 0.02 | 103.95 | 
| 6 | 3500.2 | < 0.02 | < 0.02 | 32.39 | 1.49 | 2.23 | < 0.02 | < 0.02 | 109.41 | 
| 5 | 3698.7 | < 0.02 | < 0.02 | 32.78 | 1.37 | 2.26 | < 0.02 | < 0.02 | 114.98 | 
| 4 | 3899.7 | 204.90 | 34.722 | 32.86 | 1.27 | 2.26 | < 0.02 | < 0.02 | 117.63 | 
| 3 | 4101 | < 0.02 | < 0.02 | 33.06 | 1.13 | 2.28 | < 0.02 | < 0.02 | 120.71 | 
| 2 | 4399.8 | < 0.02 | < 0.02 | 33.19 | 1.08 | 2.28 | < 0.02 | < 0.02 | 122.58 | 
| 1 | 4667.3 | 208.61 | 34.712 | 33.23 | 1.08 | 2.28 | < 0.02 | < 0.02 | 123.27 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) | 
| CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
| Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) | 
| Conductivity CTD 23-SN 4425 | Seabird | SBE-4C | 4425 | |
| Licor - CTD 23 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) | 
| Oxygen CTD 23 - SN 1794 | Seabird | SBE43 | 1794 | Oxygen (µM) | 
| Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) | 
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| Temperature CTD 23 - SN 4722 | Seabird | SBE3Plus | 4722 | Temperature (deg C) | 
| Transmissometer - CTD 23 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |