Deployment Details
Survey: - IN2017_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4425,Licor - CTD 23 - SN 70111,Oxygen CTD 23 - SN 1794,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 23 - SN 4722,Transmissometer - CTD 23 -CST-1735DR
When: 2017-03-20 14:15 to 2017-03-20 17:44 UTC
Where: 46° 04.8' S 142° 20.5' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.7 | 278.33 | 34.592 | 7.82 | 12.30 | 0.65 | 0.18 | 0.16 | 0.20 |
35 | 25.4 | < 0.02 | 34.598 | 7.69 | 12.27 | 0.64 | 0.20 | 0.16 | 0.22 |
34 | 50.4 | 266.31 | 34.767 | 7.45 | 12.23 | 0.65 | 0.49 | 0.31 | 0.67 |
33 | 76.4 | 268.68 | 34.605 | 10.68 | 11.11 | 0.83 | 0.42 | 0.30 | 1.21 |
32 | 100.3 | < 0.02 | 34.937 | 11.89 | 11.39 | 0.87 | < 0.02 | 0.02 | 2.93 |
31 | 120.5 | 239.70 | 34.949 | 12.67 | 11.26 | 0.91 | < 0.02 | 0.02 | 3.50 |
30 | 149.5 | 267.07 | 34.689 | 14.16 | 9.75 | 1.01 | < 0.02 | 0.02 | 3.60 |
29 | 176.1 | < 0.02 | < 0.02 | < 0.02 | 9.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 199.7 | < 0.02 | 34.663 | 14.35 | 9.37 | 1.02 | < 0.02 | 0.02 | 3.76 |
27 | 224.5 | 272.39 | 34.648 | 14.44 | 9.27 | 1.03 | < 0.02 | 0.02 | 3.79 |
26 | 250.4 | < 0.02 | 34.639 | 14.48 | 9.21 | 1.04 | < 0.02 | 0.02 | 3.76 |
25 | 299.9 | 273.50 | 34.627 | 14.67 | 9.13 | 1.05 | < 0.02 | 0.02 | 3.73 |
24 | 350.4 | < 0.02 | 34.620 | 14.72 | 9.09 | 1.05 | < 0.02 | 0.02 | 3.76 |
23 | 400.1 | 274.04 | 34.619 | 14.81 | 9.06 | 1.06 | < 0.02 | 0.02 | 3.81 |
22 | 599.6 | < 0.02 | 34.516 | 18.23 | 8.38 | 1.26 | < 0.02 | < 0.02 | 5.62 |
21 | 798.9 | 225.85 | 34.428 | 24.41 | 7.15 | 1.65 | < 0.02 | < 0.02 | 12.80 |
20 | 1000.1 | < 0.02 | 34.343 | 29.40 | 5.35 | 1.98 | < 0.02 | < 0.02 | 24.12 |
19 | 1201.4 | < 0.02 | < 0.02 | < 0.02 | 4.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 1300.5 | < 0.02 | 34.385 | 33.88 | 3.55 | 2.31 | < 0.02 | < 0.02 | 48.84 |
17 | 1402.1 | 187.17 | 34.429 | 34.66 | 3.26 | 2.37 | < 0.02 | < 0.02 | 56.45 |
16 | 1600.9 | < 0.02 | < 0.02 | < 0.02 | 2.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 1801.1 | 174.94 | 34.606 | 34.53 | 2.63 | 2.37 | < 0.02 | < 0.02 | 76.59 |
14 | 2000.1 | < 0.02 | 34.662 | 33.91 | 2.46 | 2.33 | < 0.02 | < 0.02 | 82.83 |
13 | 2201.2 | 179.76 | 34.702 | 33.40 | 2.32 | 2.29 | < 0.02 | < 0.02 | 88.22 |
12 | 2401.9 | < 0.02 | 34.722 | 33.15 | 2.19 | 2.28 | < 0.02 | < 0.02 | 93.66 |
11 | 2600.8 | < 0.02 | 34.731 | 33.06 | 2.03 | 2.27 | < 0.02 | < 0.02 | 99.76 |
10 | 2801.6 | 187.08 | 34.734 | 33.10 | 1.89 | 2.28 | < 0.02 | < 0.02 | 104.60 |
9 | 2999.4 | < 0.02 | 34.512 | 23.00 | 1.75 | 1.58 | < 0.02 | < 0.02 | 22.14 |
8 | 3101.8 | < 0.02 | 34.734 | 32.93 | 1.69 | 2.26 | < 0.02 | < 0.02 | 108.53 |
7 | 3300 | 197.27 | 34.731 | 32.89 | 1.56 | 2.26 | < 0.02 | < 0.02 | 111.23 |
6 | 3499.3 | < 0.02 | 34.729 | 32.89 | 1.46 | 2.26 | < 0.02 | < 0.02 | 113.48 |
5 | 3700.4 | < 0.02 | 34.725 | 32.94 | 1.35 | 2.26 | < 0.02 | < 0.02 | 115.88 |
4 | 3900.8 | 204.90 | 34.721 | 33.06 | 1.25 | 2.26 | < 0.02 | < 0.02 | 118.60 |
3 | 4100.6 | < 0.02 | 34.425 | 29.90 | 1.10 | 2.03 | < 0.02 | < 0.02 | 36.47 |
2 | 4300.3 | < 0.02 | < 0.02 | < 0.02 | 1.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 4438.8 | 208.34 | 34.712 | 33.35 | 1.06 | 2.29 | < 0.02 | < 0.02 | 123.19 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4425 | Seabird | SBE-4C | 4425 | |
Licor - CTD 23 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 1794 | Seabird | SBE43 | 1794 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 23 - SN 4722 | Seabird | SBE3Plus | 4722 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |