Deployment Details
Survey: - IN2017_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4425,Licor - CTD 23 - SN 70111,Oxygen CTD 23 - SN 1794,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Temperature CTD 23 - SN 4722,Transmissometer - CTD 23 -CST-1735DR
When: 2017-03-18 13:14 to 2017-03-18 16:41 UTC
Where: 45° 59.3' S 142° 23.2' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5.6 | < 0.02 | 34.711 | 6.96 | 12.59 | 0.61 | 0.22 | 0.19 | 0.21 |
35 | 24.2 | < 0.02 | 34.710 | 6.96 | 12.57 | 0.61 | 0.21 | 0.18 | 0.24 |
34 | 49.9 | 274.49 | 34.674 | 7.66 | 12.32 | 0.66 | 0.29 | 0.18 | 0.41 |
33 | 75.2 | < 0.02 | 34.512 | 10.74 | 10.96 | 0.85 | 0.46 | 0.21 | 0.96 |
32 | 99.7 | < 0.02 | 34.507 | 12.31 | 10.33 | 0.96 | 0.47 | 0.42 | 1.55 |
31 | 124.4 | 271.72 | 34.613 | 13.93 | 9.62 | 1.02 | < 0.02 | 0.62 | 2.75 |
30 | 149.9 | < 0.02 | 34.676 | 14.20 | 9.57 | 1.04 | < 0.02 | 0.02 | 3.43 |
29 | 172.2 | < 0.02 | 34.661 | 14.40 | 9.42 | 1.05 | < 0.02 | 0.02 | 3.55 |
28 | 198.4 | 271.63 | 34.639 | 14.57 | 9.25 | 1.06 | < 0.02 | 0.02 | 3.62 |
27 | 225.5 | < 0.02 | 34.629 | 14.69 | 9.18 | 1.06 | < 0.02 | 0.02 | 3.64 |
26 | 249.9 | < 0.02 | 34.612 | 14.82 | 9.07 | 1.07 | < 0.02 | 0.02 | 3.66 |
25 | 299.3 | 274.75 | 34.601 | 14.89 | 8.99 | 1.08 | < 0.02 | < 0.02 | 3.65 |
24 | 350.1 | < 0.02 | 34.597 | 14.99 | 8.96 | 1.09 | < 0.02 | < 0.02 | 3.67 |
23 | 399.9 | < 0.02 | < 0.02 | < 0.02 | 8.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 599.5 | 273.95 | 34.740 | 6.75 | 8.36 | 0.62 | 0.18 | 0.19 | 0.77 |
21 | 800 | < 0.02 | 34.418 | 24.93 | 7.00 | 1.70 | < 0.02 | < 0.02 | 13.61 |
20 | 999.7 | < 0.02 | 34.337 | 29.76 | 5.18 | 2.03 | < 0.02 | < 0.02 | 25.31 |
19 | 1200.4 | 202.40 | 34.354 | 32.75 | 3.98 | 2.24 | < 0.02 | < 0.02 | 40.69 |
18 | 1400.7 | < 0.02 | 34.446 | 34.64 | 3.35 | 2.39 | < 0.02 | < 0.02 | 59.12 |
17 | 1599.8 | < 0.02 | 34.546 | 35.17 | 2.96 | 2.43 | < 0.02 | < 0.02 | 75.74 |
16 | 1801 | 173.11 | 34.613 | 34.63 | 2.61 | 2.39 | < 0.02 | < 0.02 | 79.02 |
15 | 1999.8 | < 0.02 | 34.667 | 33.82 | 2.45 | 2.33 | < 0.02 | < 0.02 | 82.93 |
14 | 2199.6 | < 0.02 | 34.702 | 33.33 | 2.31 | 2.30 | < 0.02 | < 0.02 | 88.42 |
13 | 2400.5 | 181.10 | 34.723 | 33.19 | 2.17 | 2.30 | < 0.02 | < 0.02 | 95.06 |
12 | 2600.6 | < 0.02 | 34.731 | 33.08 | 2.04 | 2.29 | < 0.02 | < 0.02 | 99.74 |
11 | 2800 | < 0.02 | 34.735 | 33.01 | 1.90 | 2.28 | < 0.02 | < 0.02 | 103.94 |
10 | 3000.8 | 190.93 | 34.735 | 32.97 | 1.76 | 2.28 | < 0.02 | < 0.02 | 107.21 |
9 | 3101.7 | < 0.02 | 34.735 | 32.90 | 1.70 | 2.27 | < 0.02 | < 0.02 | 108.22 |
8 | 3299.5 | < 0.02 | 34.733 | 32.85 | 1.58 | 2.27 | < 0.02 | < 0.02 | 110.63 |
7 | 3500.6 | 200.13 | 34.730 | 32.82 | 1.46 | 2.26 | < 0.02 | < 0.02 | 112.79 |
6 | 3699.5 | < 0.02 | 34.726 | 32.95 | 1.35 | 2.27 | < 0.02 | < 0.02 | 115.70 |
5 | 3899.9 | < 0.02 | 34.722 | 33.08 | 1.26 | 2.28 | < 0.02 | < 0.02 | 118.70 |
4 | 4100.1 | 206.42 | 34.717 | 33.24 | 1.14 | 2.29 | < 0.02 | < 0.02 | 121.47 |
3 | 4300.4 | < 0.02 | 34.713 | 33.34 | 1.07 | 2.30 | < 0.02 | < 0.02 | 123.19 |
2 | 4498.9 | < 0.02 | 34.712 | 33.35 | 1.07 | 2.30 | < 0.02 | < 0.02 | 123.42 |
1 | 4579 | 208.30 | 34.712 | 33.36 | 1.07 | 2.30 | < 0.02 | < 0.02 | 123.54 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4425 | Seabird | SBE-4C | 4425 | |
Licor - CTD 23 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 1794 | Seabird | SBE43 | 1794 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
Temperature CTD 23 - SN 4722 | Seabird | SBE3Plus | 4722 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |