Deployment Details
Survey: - IN2019_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 24
Gear: Autosal Salinometer,CTD 25 - SN 1354,Conductivity CTD 25 - SN 4662,Licor - CTD 25 - SN 70111,Oxygen CTD 25-SBE 43-SN 3159,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - WET Labs ECO FLNTU,Temperature CTD 25 - SN 6130,Transmissometer - CTD 25 -CST-1421DR
When: 2019-09-25 05:48 to 2019-09-25 07:36 UTC
Where: 28° 03.9' S 154° 44.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
24 | 4.6 | 229.33 | 35.632 | 0.02 | 21.34 | 0.08 | < 0.02 | < 0.02 | 0.12 |
23 | 25.6 | 229.42 | 35.621 | 0.02 | 21.12 | 0.09 | < 0.02 | < 0.02 | 0.11 |
22 | 49.8 | < 0.02 | < 0.02 | < 0.02 | 20.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 49.9 | 229.96 | 35.732 | 0.38 | 20.05 | 0.12 | < 0.02 | 0.05 | 0.22 |
19 | 80.1 | 215.04 | 35.756 | 2.02 | 19.52 | 0.22 | < 0.02 | 0.21 | 0.70 |
20 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 19.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 100 | 203.48 | 35.720 | 3.41 | 19.25 | 0.31 | < 0.02 | 0.06 | 0.91 |
18 | 100 | < 0.02 | < 0.02 | < 0.02 | 19.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 200.2 | 187.17 | 35.437 | 8.63 | 16.30 | 0.65 | < 0.02 | < 0.02 | 2.43 |
16 | 200.3 | < 0.02 | < 0.02 | < 0.02 | 16.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 300.3 | < 0.02 | < 0.02 | < 0.02 | 14.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 300.4 | 197.67 | 35.255 | 11.10 | 14.03 | 0.80 | < 0.02 | < 0.02 | 3.43 |
12 | 499.6 | < 0.02 | < 0.02 | < 0.02 | 9.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 499.9 | 204.55 | 34.739 | 19.53 | 9.75 | 1.32 | < 0.02 | < 0.02 | 7.86 |
10 | 800.7 | < 0.02 | < 0.02 | < 0.02 | 6.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 800.7 | 203.25 | 34.453 | 26.97 | 6.53 | 1.83 | < 0.02 | < 0.02 | 21.41 |
7 | 1000.6 | 186.55 | 34.450 | 31.04 | 4.99 | 2.13 | < 0.02 | < 0.02 | 43.30 |
8 | 1000.7 | < 0.02 | < 0.02 | < 0.02 | 4.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 1100.7 | 178.60 | 34.475 | 32.34 | 4.47 | 2.23 | < 0.02 | < 0.02 | 54.82 |
6 | 1100.8 | < 0.02 | < 0.02 | < 0.02 | 4.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1300.6 | 164.89 | 34.524 | 34.12 | 3.72 | 2.37 | < 0.02 | < 0.02 | 73.76 |
4 | 1300.7 | < 0.02 | < 0.02 | < 0.02 | 3.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 1500.4 | < 0.02 | < 0.02 | < 0.02 | 3.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1500.6 | 156.45 | 34.576 | 35.30 | 3.08 | 2.47 | < 0.02 | < 0.02 | 89.65 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
Conductivity CTD 25 - SN 4662 | Seabird | SBE4C | 4662 | |
Licor - CTD 25 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 25-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Scattering - CTD 25 - WET Labs ECO FLNTU | WET Labs | FLBBNTU | 5169 | Turbidity (%) |
Temperature CTD 25 - SN 6130 | Seabird | SBE3T | 6130 | Temperature (deg C) |
Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |