Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 38
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4662,Licor - CTD 23 - SN 70677,Oxygen CTD 23 - SN 3198,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 21 - SN 6189,Temperature CTD 23 - SN 6180,Transmissometer - CTD 23 -CST-1421DR
When: 2019-06-03 22:56 UTC
Where: 14° 00.0' S 110° 00.3' E
Maximum Depth (m): 500.1
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2132 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 28.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 5.6 | < 0.02 | < 0.02 | 0.03 | 28.05 | 0.07 | < 0.02 | < 0.02 | 2.57 |
2036 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 10.3 | 200.93 | 34.290 | 0.03 | 28.06 | 0.07 | < 0.02 | < 0.02 | 2.59 |
2028 | 20 | < 0.02 | < 0.02 | 0.03 | 28.06 | 0.07 | < 0.02 | < 0.02 | 2.52 |
2029 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 32 | < 0.02 | < 0.02 | 0.03 | 28.06 | 0.08 | 0.06 | < 0.02 | 2.54 |
2027 | 32.3 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 52.2 | < 0.02 | < 0.02 | < 0.02 | 28.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 52.3 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 52.3 | 200.75 | 34.290 | 0.03 | 28.07 | 0.07 | < 0.02 | < 0.02 | 2.52 |
2022 | 52.3 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 52.3 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 52.3 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 52.4 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 52.5 | < 0.02 | < 0.02 | < 0.02 | 28.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 64.4 | < 0.02 | < 0.02 | 0.03 | 28.07 | 0.07 | < 0.02 | < 0.02 | 2.57 |
2016 | 64.5 | < 0.02 | < 0.02 | < 0.02 | 28.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 64.8 | < 0.02 | < 0.02 | < 0.02 | 28.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 76.9 | < 0.02 | < 0.02 | 0.07 | 28.07 | 0.07 | 0.02 | < 0.02 | 2.63 |
2010 | 76.9 | < 0.02 | < 0.02 | < 0.02 | 28.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 77 | < 0.02 | < 0.02 | < 0.02 | 28.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 77 | < 0.02 | < 0.02 | < 0.02 | 28.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 77 | < 0.02 | < 0.02 | < 0.02 | 28.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 77 | < 0.02 | < 0.02 | < 0.02 | 28.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 77.1 | < 0.02 | < 0.02 | < 0.02 | 28.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 100.6 | 149.12 | 34.324 | 6.96 | 24.82 | 0.59 | < 0.02 | 0.12 | 8.77 |
2006 | 125.7 | 135.10 | 34.404 | 12.15 | 21.51 | 0.87 | < 0.02 | 0.04 | 14.72 |
21 | 201.2 | 114.91 | 34.695 | 18.98 | 16.16 | 1.35 | < 0.02 | < 0.02 | 25.02 |
12004 | 279 | 101.65 | 34.652 | 25.38 | 12.41 | 1.79 | < 0.02 | < 0.02 | 36.15 |
12003 | 300.9 | 104.82 | 34.696 | 25.60 | 11.91 | 1.81 | < 0.02 | < 0.02 | 36.18 |
12002 | 400.2 | 124.25 | 34.702 | 27.10 | 9.77 | 1.89 | < 0.02 | < 0.02 | 36.30 |
12001 | 500.1 | 116.65 | 34.663 | 29.99 | 8.64 | 2.10 | < 0.02 | < 0.02 | 42.86 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4662 | Seabird | SBE-4C | 4662 | |
Licor - CTD 23 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 23 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |