Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 30
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4662,Licor - CTD 23 - SN 70677,Oxygen CTD 23 - SN 3198,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 21 - SN 6189,Temperature CTD 23 - SN 6180,Transmissometer - CTD 23 -CST-1421DR
When: 2019-05-30 12:00 to 2019-05-30 12:55 UTC
Where: 20° 00.2' S 110° 01.0' E
Maximum Depth (m): 501.9
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 26.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 26.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 26.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 5.6 | 208.57 | 34.935 | 0.02 | 26.62 | 0.06 | < 0.02 | < 0.02 | 2.39 |
2036 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 26.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2132 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 26.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 10.8 | 209.01 | 34.978 | 0.02 | 26.55 | 0.06 | < 0.02 | < 0.02 | 2.50 |
2029 | 21.7 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 22.1 | 209.82 | 35.112 | 0.02 | 26.21 | 0.05 | < 0.02 | < 0.02 | 2.72 |
2027 | 32.5 | < 0.02 | < 0.02 | < 0.02 | 26.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 32.7 | 209.77 | 35.138 | 0.02 | 26.20 | 0.05 | < 0.02 | < 0.02 | 2.72 |
2025 | 50.1 | 209.37 | 35.149 | 0.02 | 26.14 | 0.06 | < 0.02 | < 0.02 | 2.71 |
2024 | 55.8 | < 0.02 | < 0.02 | < 0.02 | 26.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 55.9 | 209.15 | 35.148 | 0.02 | 26.12 | 0.06 | < 0.02 | < 0.02 | 2.75 |
2023 | 55.9 | < 0.02 | < 0.02 | < 0.02 | 26.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 56 | < 0.02 | < 0.02 | < 0.02 | 26.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 56 | < 0.02 | < 0.02 | < 0.02 | 26.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 56 | < 0.02 | < 0.02 | < 0.02 | 26.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 56 | < 0.02 | < 0.02 | < 0.02 | 26.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 69 | 208.97 | 35.143 | 0.02 | 26.07 | 0.06 | < 0.02 | < 0.02 | 2.79 |
2017 | 69.2 | < 0.02 | < 0.02 | < 0.02 | 26.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 25.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 80.4 | 202.23 | 35.014 | 0.07 | 25.18 | 0.13 | < 0.02 | 0.02 | 3.88 |
2015 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 25.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 84.6 | < 0.02 | < 0.02 | < 0.02 | 23.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 84.6 | 181.59 | 34.914 | 1.44 | 23.57 | 0.29 | < 0.02 | 0.15 | 5.63 |
2012 | 84.6 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 84.7 | < 0.02 | < 0.02 | < 0.02 | 23.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 84.7 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 100 | 161.09 | 34.944 | 6.65 | 22.30 | 0.54 | < 0.02 | 0.10 | 8.06 |
2006 | 115.4 | 165.07 | 35.093 | 6.43 | 21.37 | 0.53 | < 0.02 | 0.03 | 8.04 |
21 | 125.2 | 167.66 | 35.162 | 6.17 | 21.22 | 0.51 | < 0.02 | 0.02 | 7.59 |
12004 | 200.5 | 195.62 | 35.659 | 4.28 | 18.54 | 0.37 | < 0.02 | < 0.02 | 4.70 |
12003 | 301.2 | 204.46 | 35.200 | 10.69 | 13.25 | 0.82 | < 0.02 | < 0.02 | 9.08 |
12002 | 400.1 | 240.95 | 34.843 | 13.40 | 10.53 | 0.98 | < 0.02 | < 0.02 | 4.58 |
12001 | 501.9 | 232.86 | 34.640 | 18.88 | 8.95 | 1.30 | < 0.02 | < 0.02 | 7.22 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4662 | Seabird | SBE-4C | 4662 | |
Licor - CTD 23 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 23 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |