Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 26
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4662,Licor - CTD 23 - SN 70677,Oxygen CTD 23 - SN 3198,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 21 - SN 6189,Temperature CTD 23 - SN 6180,Transmissometer - CTD 23 -CST-1421DR
When: 2019-05-28 11:49 to 2019-05-28 12:38 UTC
Where: 23° 00.0' S 110° 00.0' E
Maximum Depth (m): 500.3
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2033 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 25.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2132 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 25.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 6.6 | 213.57 | 35.268 | 0.02 | 25.06 | 0.04 | < 0.02 | < 0.02 | 2.59 |
2034 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 25.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 25.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 25.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2030 | 10.8 | 213.48 | 35.267 | 0.03 | 25.01 | 0.04 | < 0.02 | < 0.02 | 2.61 |
2029 | 21.5 | < 0.02 | < 0.02 | < 0.02 | 24.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 22.4 | 213.75 | 35.270 | 0.02 | 24.95 | 0.04 | < 0.02 | < 0.02 | 2.64 |
2026 | 32.1 | 213.97 | 35.284 | 0.03 | 24.92 | 0.04 | < 0.02 | < 0.02 | 2.66 |
2027 | 32.3 | < 0.02 | < 0.02 | < 0.02 | 24.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 55 | < 0.02 | < 0.02 | < 0.02 | 24.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 55.1 | 214.82 | 35.323 | 0.03 | 24.52 | 0.04 | < 0.02 | < 0.02 | 2.73 |
2025 | 55.1 | < 0.02 | < 0.02 | < 0.02 | 24.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 55.1 | < 0.02 | < 0.02 | < 0.02 | 24.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 55.1 | < 0.02 | < 0.02 | < 0.02 | 24.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 55.2 | < 0.02 | < 0.02 | < 0.02 | 24.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 55.2 | < 0.02 | < 0.02 | < 0.02 | 24.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 55.3 | < 0.02 | < 0.02 | < 0.02 | 24.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 68 | 214.42 | 35.326 | 0.02 | 24.22 | 0.05 | < 0.02 | < 0.02 | 2.80 |
2017 | 68.1 | < 0.02 | < 0.02 | < 0.02 | 24.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 79 | < 0.02 | < 0.02 | < 0.02 | 23.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 79 | 208.48 | 35.225 | 0.53 | 23.14 | 0.14 | < 0.02 | 0.06 | 3.60 |
2011 | 79.1 | < 0.02 | < 0.02 | < 0.02 | 23.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 79.1 | < 0.02 | < 0.02 | < 0.02 | 23.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 79.1 | < 0.02 | < 0.02 | < 0.02 | 23.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 79.2 | < 0.02 | < 0.02 | < 0.02 | 23.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 79.2 | < 0.02 | < 0.02 | < 0.02 | 23.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 79.3 | < 0.02 | < 0.02 | < 0.02 | 23.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 89.1 | 188.34 | 35.200 | 2.44 | 21.99 | 0.30 | < 0.02 | 0.13 | 5.00 |
2006 | 98.5 | 193.87 | 35.330 | 1.89 | 21.71 | 0.25 | < 0.02 | 0.05 | 4.08 |
21 | 125.8 | 192.80 | 35.484 | 3.07 | 20.77 | 0.29 | < 0.02 | 0.02 | 4.22 |
12004 | 200.5 | 201.02 | 35.709 | 3.47 | 18.60 | 0.31 | < 0.02 | < 0.02 | 3.97 |
12003 | 300.8 | 222.05 | 35.447 | 5.73 | 14.79 | 0.49 | < 0.02 | < 0.02 | 3.25 |
12002 | 401.5 | 236.03 | 34.978 | 11.35 | 11.46 | 0.85 | < 0.02 | < 0.02 | 4.46 |
12001 | 500.3 | 240.05 | 34.738 | 15.78 | 9.66 | 1.11 | < 0.02 | < 0.02 | 5.19 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4662 | Seabird | SBE-4C | 4662 | |
Licor - CTD 23 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 23 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |