Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4662,Licor - CTD 23 - SN 70677,Oxygen CTD 23 - SN 3198,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 21 - SN 6189,Temperature CTD 23 - SN 6180,Transmissometer - CTD 23 -CST-1421DR
When: 2019-05-18 11:58 to 2019-05-18 12:43 UTC
Where: 37° 59.6' S 110° 00.0' E
Maximum Depth (m): 500.7
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
12032 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 14.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12035 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 14.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12036 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 14.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12033 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 14.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12031 | 6 | < 0.02 | < 0.02 | < 0.02 | 14.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12034 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 14.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12030 | 6.4 | 260.33 | 35.228 | 3.36 | 14.16 | 0.36 | 0.07 | 0.14 | 0.59 |
12029 | 11.6 | 260.55 | 35.220 | 3.42 | 14.13 | 0.36 | 0.07 | 0.15 | 0.59 |
12028 | 16.9 | < 0.02 | < 0.02 | < 0.02 | 14.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12027 | 17.1 | < 0.02 | < 0.02 | < 0.02 | 14.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12026 | 17.2 | 260.60 | 35.215 | 3.47 | 14.12 | 0.37 | 0.08 | 0.15 | 0.49 |
12025 | 25.7 | < 0.02 | < 0.02 | < 0.02 | 14.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12024 | 25.9 | < 0.02 | < 0.02 | < 0.02 | 14.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12023 | 26 | 260.64 | 35.203 | 3.57 | 14.07 | 0.37 | 0.09 | 0.15 | 0.53 |
12018 | 44 | < 0.02 | < 0.02 | < 0.02 | 14.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12020 | 44.1 | < 0.02 | < 0.02 | < 0.02 | 14.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12019 | 44.1 | < 0.02 | < 0.02 | < 0.02 | 14.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12017 | 44.2 | < 0.02 | < 0.02 | < 0.02 | 14.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12022 | 44.2 | < 0.02 | < 0.02 | < 0.02 | 14.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12016 | 44.4 | 260.95 | 35.161 | 3.95 | 14.03 | 0.40 | 0.10 | 0.16 | 0.52 |
12021 | 44.4 | < 0.02 | < 0.02 | < 0.02 | 14.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12015 | 50.3 | 261.22 | 35.135 | 4.15 | 13.80 | 0.41 | 0.12 | 0.17 | 0.51 |
12013 | 53.8 | 261.22 | 35.165 | 3.89 | 13.85 | 0.40 | 0.10 | 0.16 | 0.56 |
12014 | 53.9 | < 0.02 | < 0.02 | < 0.02 | 13.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12008 | 65.4 | < 0.02 | < 0.02 | < 0.02 | 13.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12010 | 65.5 | < 0.02 | < 0.02 | < 0.02 | 13.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 65.5 | 260.28 | 35.112 | 4.15 | 13.69 | 0.41 | 0.12 | 0.17 | 0.63 |
12009 | 65.5 | < 0.02 | < 0.02 | < 0.02 | 13.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12011 | 65.5 | < 0.02 | < 0.02 | < 0.02 | 13.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12012 | 65.8 | < 0.02 | < 0.02 | < 0.02 | 13.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12006 | 100.7 | 245.55 | 35.244 | 5.06 | 13.45 | 0.47 | < 0.02 | 0.04 | 1.16 |
21 | 126.1 | 248.27 | 35.175 | 5.97 | 12.85 | 0.53 | < 0.02 | 0.02 | 1.23 |
12004 | 200.2 | 258.32 | 34.921 | 9.82 | 11.27 | 0.76 | < 0.02 | < 0.02 | 2.18 |
12003 | 299.3 | 266.00 | 34.754 | 12.25 | 10.17 | 0.91 | < 0.02 | < 0.02 | 2.75 |
12002 | 400.7 | 268.06 | 34.723 | 12.26 | 9.84 | 0.91 | < 0.02 | < 0.02 | 2.78 |
12001 | 500.7 | 252.87 | 34.707 | 15.25 | 9.64 | 1.08 | < 0.02 | < 0.02 | 3.91 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4662 | Seabird | SBE-4C | 4662 | |
Licor - CTD 23 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 23 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |