Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4662,Licor - CTD 23 - SN 70677,Oxygen CTD 23 - SN 3198,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 21 - SN 6189,Temperature CTD 23 - SN 6180,Transmissometer - CTD 23 -CST-1421DR
When: 2019-05-17 22:31 to 2019-05-18 01:51 UTC
Where: 38° 00.0' S 110° 00.0' E
Maximum Depth (m): 4344.7
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 13.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 13.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 4.8 | 262.79 | 35.090 | 4.57 | 13.61 | 0.44 | 0.10 | 0.16 | 0.60 |
33 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 13.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 13.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 10.8 | 262.61 | 35.083 | 4.63 | 13.58 | 0.45 | 0.11 | 0.16 | 0.55 |
29 | 25.2 | 262.47 | 35.079 | 4.66 | 13.54 | 0.45 | 0.11 | 0.16 | 0.55 |
30 | 25.4 | < 0.02 | < 0.02 | < 0.02 | 13.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 13.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 13.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 13.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 50.3 | < 0.02 | < 0.02 | < 0.02 | 13.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 13.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 13.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 13.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 50.5 | < 0.02 | < 0.02 | < 0.02 | 13.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 50.6 | 265.51 | 34.987 | 5.53 | 13.22 | 0.50 | 0.13 | 0.18 | 0.50 |
20 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 13.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 13.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 75.7 | 266.22 | 34.926 | 6.14 | 13.02 | 0.55 | 0.20 | 0.19 | 0.52 |
16 | 100.5 | < 0.02 | < 0.02 | < 0.02 | 12.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 100.5 | 265.20 | 34.815 | 7.76 | 12.29 | 0.67 | 0.51 | 0.27 | 0.64 |
14 | 124.6 | 249.43 | 35.091 | 6.76 | 12.85 | 0.58 | < 0.02 | 0.17 | 1.31 |
13 | 150.9 | 246.84 | 35.164 | 6.14 | 12.72 | 0.54 | < 0.02 | < 0.02 | 1.15 |
11 | 201.8 | 250.50 | 35.015 | 8.36 | 11.76 | 0.68 | < 0.02 | < 0.02 | 1.54 |
12 | 201.9 | < 0.02 | < 0.02 | < 0.02 | 11.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 301 | 261.45 | 34.785 | 11.98 | 10.31 | 0.90 | < 0.02 | < 0.02 | 2.71 |
8 | 402.5 | 250.77 | 34.770 | 13.88 | 10.05 | 1.00 | < 0.02 | < 0.02 | 3.04 |
9 | 402.5 | < 0.02 | < 0.02 | < 0.02 | 10.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 502.4 | 247.69 | 34.724 | 15.40 | 9.68 | 1.09 | < 0.02 | < 0.02 | 3.59 |
6 | 1003.8 | 200.13 | 34.375 | 30.57 | 5.20 | 2.07 | < 0.02 | < 0.02 | 29.28 |
5 | 2001.1 | 169.49 | 34.681 | 34.09 | 2.54 | 2.36 | < 0.02 | < 0.02 | 89.23 |
4 | 2999.2 | 201.56 | 34.740 | 31.92 | 1.64 | 2.19 | < 0.02 | < 0.02 | 102.84 |
3 | 4000.7 | 212.27 | 34.708 | 32.94 | 0.94 | 2.28 | < 0.02 | < 0.02 | 123.94 |
2 | 4169.2 | 212.59 | 34.706 | 33.01 | 0.92 | 2.28 | < 0.02 | < 0.02 | 125.04 |
1 | 4344.7 | 212.72 | 34.706 | 33.07 | 0.93 | 2.28 | < 0.02 | < 0.02 | 125.19 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4662 | Seabird | SBE-4C | 4662 | |
Licor - CTD 23 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 23 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |