Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4662,Licor - CTD 23 - SN 70677,Oxygen CTD 23 - SN 3198,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 21 - SN 6189,Temperature CTD 23 - SN 6180,Transmissometer - CTD 23 -CST-1421DR
When: 2019-05-17 11:59 to 2019-05-17 12:49 UTC
Where: 39° 27.2' S 109° 58.0' E
Maximum Depth (m): 501.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
31 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 5.8 | 271.49 | 34.797 | 7.62 | 12.20 | 0.64 | 0.09 | 0.27 | 0.64 |
33 | 6 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 18.2 | 271.45 | 34.797 | 7.62 | 12.20 | 0.64 | 0.10 | 0.27 | 0.68 |
28 | 18.4 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 18.5 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 25.9 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 26.1 | 271.36 | 34.798 | 7.62 | 12.20 | 0.64 | 0.09 | 0.27 | 0.70 |
25 | 26.2 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 45.4 | < 0.02 | < 0.02 | < 0.02 | 12.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 46.2 | 270.96 | 34.796 | 7.63 | 12.21 | 0.64 | 0.10 | 0.27 | 0.74 |
19 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 12.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 12.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 12.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 50.8 | 270.91 | 34.796 | 7.64 | 12.21 | 0.64 | 0.10 | 0.28 | 0.73 |
21 | 51 | < 0.02 | < 0.02 | < 0.02 | 12.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 56.8 | < 0.02 | < 0.02 | < 0.02 | 12.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 56.9 | 270.96 | 34.796 | 7.63 | 12.21 | 0.63 | 0.09 | 0.27 | 0.68 |
13 | 66.9 | 271.40 | 34.797 | 7.62 | 12.21 | 0.64 | 0.17 | 0.28 | 0.65 |
14 | 67.2 | < 0.02 | < 0.02 | < 0.02 | 12.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 71.1 | 270.07 | 34.798 | 7.76 | 12.20 | 0.65 | 0.18 | 0.30 | 0.72 |
12 | 71.2 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 84.7 | < 0.02 | < 0.02 | < 0.02 | 11.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 84.8 | < 0.02 | < 0.02 | < 0.02 | 11.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 84.9 | 262.79 | 34.815 | 9.23 | 11.86 | 0.74 | 0.10 | 0.40 | 1.44 |
10 | 85 | < 0.02 | < 0.02 | < 0.02 | 11.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 107.1 | 258.41 | 34.851 | 10.31 | 11.20 | 0.80 | < 0.02 | 0.02 | 2.29 |
5 | 125.6 | 261.00 | 34.820 | 10.98 | 10.80 | 0.84 | < 0.02 | < 0.02 | 2.55 |
4 | 200.9 | 266.36 | 34.750 | 12.30 | 10.14 | 0.92 | < 0.02 | < 0.02 | 3.03 |
3 | 299.1 | 266.13 | 34.719 | 13.16 | 9.88 | 0.97 | < 0.02 | < 0.02 | 3.32 |
2 | 399.9 | 259.39 | 34.717 | 14.34 | 9.75 | 1.04 | < 0.02 | < 0.02 | 3.81 |
1 | 501.2 | 250.10 | 34.678 | 16.03 | 9.44 | 1.14 | < 0.02 | < 0.02 | 4.40 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4662 | Seabird | SBE-4C | 4662 | |
Licor - CTD 23 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 23 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |