Deployment Details
Survey: - IN2019_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: Autosal Salinometer,CTD 23 - SN 1312,Chelsea Chelsea Aquatracka III Fluorometer,Conductivity CTD 23-SN 4662,Licor - CTD 23 - SN 70677,Oxygen CTD 23 - SN 3198,Pressure CTD 23,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Seabird SBE-32,Temperature CTD 21 - SN 6189,Temperature CTD 23 - SN 6180,Transmissometer - CTD 23 -CST-1421DR
When: 2019-05-16 21:39 to 2019-05-17 01:09 UTC
Where: 39° 29.5' S 109° 59.0' E
Maximum Depth (m): 4636.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
33 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 12.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 4.7 | 270.96 | 34.796 | 7.61 | 12.18 | 0.64 | 0.11 | 0.27 | 0.66 |
34 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 12.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 12.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 12.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 10.5 | 270.87 | 34.795 | 7.62 | 12.19 | 0.63 | 0.11 | 0.27 | 0.68 |
29 | 25 | 270.78 | 34.794 | 7.64 | 12.20 | 0.64 | 0.11 | 0.27 | 0.69 |
30 | 25.4 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 50.2 | 270.69 | 34.796 | 7.63 | 12.20 | 0.64 | 0.12 | 0.27 | 0.69 |
24 | 50.3 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 50.3 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 50.5 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 50.5 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 75 | 269.75 | 34.798 | 7.79 | 12.20 | 0.65 | 0.11 | 0.30 | 0.74 |
16 | 99.7 | 259.84 | 34.843 | 10.05 | 11.35 | 0.79 | < 0.02 | 0.18 | 2.05 |
15 | 109.6 | 258.54 | 34.849 | 10.39 | 11.13 | 0.81 | < 0.02 | 0.02 | 2.28 |
14 | 126.3 | 259.93 | 34.824 | 10.84 | 10.82 | 0.83 | < 0.02 | < 0.02 | 2.37 |
13 | 150.4 | 262.29 | 34.736 | 11.43 | 10.50 | 0.87 | < 0.02 | < 0.02 | 2.47 |
12 | 201.6 | < 0.02 | < 0.02 | < 0.02 | 10.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 201.7 | 265.24 | 34.736 | 12.19 | 10.11 | 0.91 | < 0.02 | < 0.02 | 2.64 |
10 | 301 | 266.85 | 34.707 | 13.21 | 9.81 | 0.97 | < 0.02 | < 0.02 | 3.23 |
8 | 399.9 | 259.30 | 34.715 | 14.36 | 9.75 | 1.04 | 0.03 | < 0.02 | 3.72 |
9 | 400 | < 0.02 | < 0.02 | < 0.02 | 9.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 500.6 | 249.57 | 34.675 | 16.05 | 9.43 | 1.15 | < 0.02 | < 0.02 | 4.38 |
6 | 1001.7 | 208.75 | 34.353 | 30.01 | 5.24 | 2.04 | < 0.02 | < 0.02 | 26.25 |
5 | 2000.4 | 171.27 | 34.673 | 33.88 | 2.56 | 2.36 | < 0.02 | < 0.02 | 85.95 |
4 | 2998.2 | 202.18 | 34.740 | 31.73 | 1.63 | 2.20 | < 0.02 | < 0.02 | 102.85 |
3 | 3999.2 | 213.57 | 34.708 | 32.79 | 0.92 | 2.28 | < 0.02 | < 0.02 | 124.50 |
2 | 4323.4 | 214.86 | 34.706 | 32.85 | 0.90 | 2.29 | < 0.02 | < 0.02 | 125.85 |
1 | 4636.5 | 214.55 | 34.705 | 32.91 | 0.92 | 2.29 | < 0.02 | < 0.02 | 126.49 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71613 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Chelsea Aquatracka III Fluorometer | Chelsea Tech | Aquatracka III | 11-8206-01 | Fluorescence (arbitrary units) |
Conductivity CTD 23-SN 4662 | Seabird | SBE-4C | 4662 | |
Licor - CTD 23 - SN 70677 | QCP | 2300 | 70677 | PAR (uE/m**2/sec) |
Oxygen CTD 23 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
Pressure CTD 23 | Digiquartz | 410K-134 | 1312 | Pressure (decibars) |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 23 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
Transmissometer - CTD 23 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |