Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: CTD 23 - SN 1312,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 21 - SN 6189,ThermoSalinoGraph (TSG)-SN 3439,Transmissometer
When: 2019-05-01 19:44 to 2019-05-01 22:24 UTC
Where: 38° 56.4' S 140° 54.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 10.4 | 251.31 | 35.290 | 0.21 | 15.67 | 0.18 | < 0.02 | 0.03 | 0.26 |
36 | 10.7 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 20.7 | 251.22 | < 0.02 | 0.22 | 15.68 | 0.19 | 0.02 | 0.04 | 0.25 |
34 | 20.7 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 41.8 | 251.17 | 35.290 | 0.22 | 15.68 | 0.18 | 0.02 | 0.04 | 0.24 |
32 | 41.9 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 54.6 | 250.32 | 35.259 | 0.54 | 15.49 | 0.22 | 0.04 | 0.07 | 0.26 |
29 | 100.2 | < 0.02 | < 0.02 | < 0.02 | 13.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 100.5 | 236.39 | 35.315 | 5.06 | 13.58 | 0.48 | < 0.02 | < 0.02 | 1.32 |
26 | 160.7 | 243.45 | 35.284 | 6.44 | 12.74 | 0.55 | < 0.02 | < 0.02 | 1.36 |
27 | 160.8 | < 0.02 | < 0.02 | < 0.02 | 12.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 220.6 | 249.65 | 35.165 | 7.73 | 12.07 | 0.63 | < 0.02 | < 0.02 | 1.65 |
24 | 274.8 | < 0.02 | < 0.02 | < 0.02 | 11.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 300.1 | 253.45 | 34.948 | 11.33 | 10.89 | 0.84 | < 0.02 | < 0.02 | 2.60 |
22 | 323.5 | 253.41 | 34.928 | 11.66 | 10.78 | 0.86 | < 0.02 | < 0.02 | 2.73 |
21 | 351.1 | 252.56 | 34.871 | 12.79 | 10.44 | 0.93 | < 0.02 | < 0.02 | 3.03 |
19 | 375.4 | 250.32 | 34.800 | 14.27 | 10.06 | 1.02 | < 0.02 | < 0.02 | 3.54 |
20 | 375.4 | < 0.02 | < 0.02 | < 0.02 | 10.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 401 | 248.54 | 34.741 | 15.58 | 9.70 | 1.09 | < 0.02 | < 0.02 | 4.05 |
17 | 450.6 | < 0.02 | < 0.02 | < 0.02 | 9.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 450.6 | 250.64 | 34.679 | 16.47 | 9.30 | 1.15 | < 0.02 | < 0.02 | 4.42 |
15 | 500.6 | 252.87 | 34.633 | 17.13 | 9.01 | 1.19 | < 0.02 | < 0.02 | 4.74 |
13 | 600.1 | 244.52 | 34.567 | 19.24 | 8.54 | 1.32 | < 0.02 | < 0.02 | 6.32 |
14 | 600.2 | < 0.02 | < 0.02 | < 0.02 | 8.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 801.1 | 205.93 | 34.457 | 26.40 | 6.92 | 1.78 | < 0.02 | < 0.02 | 17.63 |
11 | 1001 | 192.71 | 34.397 | 32.02 | 4.62 | 2.19 | < 0.02 | < 0.02 | 40.24 |
10 | 1299.9 | 172.93 | 34.490 | 35.07 | 3.20 | 2.43 | < 0.02 | < 0.02 | 66.23 |
8 | 1601.1 | 167.03 | 34.608 | 35.02 | 2.63 | 2.43 | < 0.02 | < 0.02 | 79.93 |
9 | 1601.3 | < 0.02 | < 0.02 | < 0.02 | 2.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 1801.2 | 169.04 | 34.664 | 34.54 | 2.47 | 2.39 | < 0.02 | < 0.02 | 87.01 |
6 | 2200 | 174.49 | 34.718 | 33.78 | 2.17 | 2.35 | < 0.02 | < 0.02 | 100.10 |
4 | 2599.1 | 181.68 | 34.730 | 33.42 | 1.94 | 2.32 | < 0.02 | < 0.02 | 106.37 |
5 | 2599.4 | < 0.02 | < 0.02 | < 0.02 | 1.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 3000.8 | < 0.02 | < 0.02 | < 0.02 | 1.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 3000.8 | 189.27 | 34.731 | 33.14 | 1.68 | 2.30 | < 0.02 | < 0.02 | 111.24 |
1 | 3090.8 | 191.02 | 34.731 | 33.12 | 1.60 | 2.30 | < 0.02 | < 0.02 | 112.53 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3439 | Seabird | SBE 21 | 3439 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) |