Please login if you have access to particular applications.
Deployment Details
Survey: - IN2019_V02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 21
Gear: CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 6180,ThermoSalinoGraph (TSG)-SN 3439,Transmissometer
When: 2019-03-30 01:01 to 2019-03-30 02:06 UTC
Where: 46° 51.6' S 142° 18.3' E
Maximum Depth (m): 301
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
22 | 9.6 | < 0.02 | < 0.02 | < 0.02 | 10.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 9.7 | < 0.02 | < 0.02 | < 0.02 | 10.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 10.1 | < 0.02 | < 0.02 | < 0.02 | 10.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 10.7 | 281.77 | 34.563 | 10.82 | 10.32 | 0.84 | 0.08 | 0.18 | 1.51 |
17 | 20 | < 0.02 | < 0.02 | < 0.02 | 10.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 20.6 | 281.72 | 34.561 | 10.81 | 10.32 | 0.84 | 0.08 | 0.18 | 1.47 |
18 | 20.7 | < 0.02 | < 0.02 | < 0.02 | 10.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 20.9 | < 0.02 | < 0.02 | < 0.02 | 10.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 29.7 | < 0.02 | < 0.02 | < 0.02 | 10.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 30.1 | < 0.02 | < 0.02 | < 0.02 | 10.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 30.3 | < 0.02 | < 0.02 | < 0.02 | 10.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 30.7 | 281.77 | 34.563 | 10.82 | 10.32 | 0.84 | 0.08 | 0.18 | 1.47 |
9 | 59.9 | < 0.02 | < 0.02 | < 0.02 | 10.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 60.1 | < 0.02 | < 0.02 | < 0.02 | 10.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 60.3 | < 0.02 | < 0.02 | < 0.02 | 10.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 60.4 | 281.32 | 34.562 | 10.86 | 10.30 | 0.84 | 0.09 | 0.18 | 1.47 |
8 | 90.2 | 278.82 | 34.566 | 11.57 | 10.13 | 0.89 | 0.13 | 0.17 | 1.79 |
7 | 90.5 | < 0.02 | < 0.02 | < 0.02 | 10.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 120.2 | < 0.02 | < 0.02 | < 0.02 | 9.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 120.3 | 269.93 | 34.625 | 14.33 | 9.50 | 1.04 | < 0.02 | 0.02 | 3.43 |
3 | 300.8 | < 0.02 | < 0.02 | < 0.02 | 9.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 300.8 | < 0.02 | < 0.02 | < 0.02 | 9.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 301 | < 0.02 | < 0.02 | < 0.02 | 9.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 301 | 272.74 | 34.602 | 14.99 | 9.11 | 1.08 | < 0.02 | < 0.02 | 3.64 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 4799 | Turbidity (%) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 6180 | Seabird | SBE3T | 6180 | Temperature (deg C) |
ThermoSalinoGraph (TSG)-SN 3439 | Seabird | SBE 21 | 3439 | Salinity (psu) |
Transmissometer | SeaTech | Transmittance (%) |