Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 21
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-12 02:59 to 2018-04-12 05:01 UTC
Where: 33° 51.1' S 154° 14.1' E
Maximum Depth (m): 1499.9
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 10.9 | 215.09 | 35.635 | 0.02 | 24.46 | 0.05 | < 0.02 | < 0.02 | 0.14 |
35 | 11.3 | < 0.02 | < 0.02 | < 0.02 | 24.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 20 | < 0.02 | < 0.02 | 0.02 | 24.42 | 0.05 | < 0.02 | < 0.02 | 0.18 |
33 | 31.8 | < 0.02 | < 0.02 | 0.02 | 24.42 | 0.04 | < 0.02 | < 0.02 | 0.13 |
32 | 40.3 | < 0.02 | < 0.02 | 0.02 | 24.39 | 0.04 | < 0.02 | < 0.02 | 0.13 |
31 | 50.3 | < 0.02 | < 0.02 | < 0.02 | 24.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 50.4 | < 0.02 | < 0.02 | 0.02 | 24.36 | 0.04 | < 0.02 | < 0.02 | 0.11 |
29 | 60.8 | < 0.02 | < 0.02 | 0.02 | 24.36 | 0.04 | < 0.02 | < 0.02 | 0.15 |
28 | 70.5 | < 0.02 | < 0.02 | 0.02 | 24.35 | 0.04 | < 0.02 | < 0.02 | 0.13 |
26 | 80.5 | < 0.02 | < 0.02 | 0.02 | 24.34 | 0.04 | < 0.02 | < 0.02 | 0.12 |
27 | 80.8 | < 0.02 | < 0.02 | 0.02 | 24.34 | 0.04 | < 0.02 | < 0.02 | 0.13 |
25 | 90.8 | < 0.02 | < 0.02 | 0.02 | 24.34 | 0.04 | < 0.02 | < 0.02 | 0.13 |
24 | 100.1 | < 0.02 | < 0.02 | 0.03 | 24.22 | 0.04 | < 0.02 | < 0.02 | 0.12 |
23 | 105 | < 0.02 | < 0.02 | 0.25 | 23.61 | 0.11 | < 0.02 | 0.14 | 0.14 |
21 | 109.7 | < 0.02 | < 0.02 | 0.42 | 23.52 | 0.13 | < 0.02 | 0.18 | 0.15 |
22 | 109.7 | < 0.02 | < 0.02 | 0.39 | 23.52 | 0.12 | < 0.02 | 0.18 | 0.16 |
20 | 115.6 | < 0.02 | < 0.02 | 0.69 | 23.29 | 0.15 | < 0.02 | 0.22 | 0.17 |
19 | 120.2 | < 0.02 | < 0.02 | 0.84 | 23.19 | 0.15 | < 0.02 | 0.22 | 0.14 |
18 | 129.1 | < 0.02 | < 0.02 | 1.50 | 22.87 | 0.20 | < 0.02 | 0.10 | 0.15 |
17 | 140.2 | < 0.02 | < 0.02 | 2.25 | 22.55 | 0.25 | < 0.02 | 0.09 | 0.27 |
16 | 150.5 | 187.36 | 35.739 | 2.89 | 22.02 | 0.29 | < 0.02 | 0.04 | 0.40 |
15 | 160.1 | < 0.02 | < 0.02 | 3.14 | 21.71 | 0.30 | < 0.02 | 0.03 | 0.44 |
14 | 160.3 | < 0.02 | < 0.02 | 3.14 | 21.71 | 0.30 | < 0.02 | 0.03 | 0.46 |
13 | 169.8 | < 0.02 | < 0.02 | 3.20 | 21.45 | 0.31 | < 0.02 | 0.02 | 0.45 |
12 | 180.4 | < 0.02 | < 0.02 | 3.38 | 21.12 | 0.32 | < 0.02 | 0.02 | 0.47 |
11 | 189.2 | < 0.02 | < 0.02 | 3.28 | 20.86 | 0.32 | < 0.02 | 0.02 | 0.49 |
10 | 201.2 | < 0.02 | < 0.02 | 3.00 | 20.63 | 0.31 | < 0.02 | 0.02 | 0.46 |
9 | 251.9 | 202.07 | 35.748 | 3.32 | 19.67 | 0.32 | < 0.02 | 0.02 | 0.58 |
8 | 351 | < 0.02 | < 0.02 | 4.59 | 18.51 | 0.39 | < 0.02 | 0.02 | 0.93 |
7 | 500.7 | 194.12 | 35.361 | 9.36 | 15.42 | 0.70 | < 0.02 | < 0.02 | 2.51 |
6 | 666 | < 0.02 | < 0.02 | 14.73 | 11.87 | 1.04 | < 0.02 | < 0.02 | 4.74 |
5 | 831.8 | < 0.02 | < 0.02 | 22.41 | 8.53 | 1.53 | < 0.02 | < 0.02 | 10.64 |
4 | 999.5 | 204.84 | 34.460 | 26.77 | 6.71 | 1.83 | < 0.02 | < 0.02 | 20.06 |
3 | 1165.3 | < 0.02 | < 0.02 | 29.45 | 5.72 | 2.03 | < 0.02 | < 0.02 | 31.45 |
2 | 1330.8 | < 0.02 | < 0.02 | 31.84 | 4.82 | 2.21 | < 0.02 | < 0.02 | 47.85 |
1 | 1499.9 | 175.24 | 34.499 | 33.45 | 4.15 | 2.35 | < 0.02 | < 0.02 | 63.34 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |