Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 20
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-11 22:00 to 2018-04-11 23:51 UTC
Where: 34° 02.4' S 153° 42.3' E
Maximum Depth (m): 1517.3
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 10 | 208.22 | 35.333 | 0.04 | 25.97 | 0.06 | < 0.02 | < 0.02 | 0.19 |
35 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 25.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 21.5 | < 0.02 | < 0.02 | 0.02 | 25.97 | 0.04 | < 0.02 | < 0.02 | 0.21 |
33 | 30.5 | < 0.02 | < 0.02 | 0.02 | 25.97 | 0.04 | < 0.02 | < 0.02 | 0.21 |
32 | 39.5 | < 0.02 | < 0.02 | < 0.02 | 25.89 | 0.03 | < 0.02 | < 0.02 | 0.20 |
31 | 39.6 | < 0.02 | < 0.02 | < 0.02 | 25.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 49.8 | < 0.02 | < 0.02 | < 0.02 | 25.33 | 0.03 | < 0.02 | < 0.02 | 0.18 |
29 | 59.7 | < 0.02 | < 0.02 | < 0.02 | 25.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 60 | < 0.02 | < 0.02 | < 0.02 | 25.19 | 0.04 | < 0.02 | < 0.02 | 0.18 |
27 | 70.1 | < 0.02 | < 0.02 | 0.02 | 24.74 | 0.06 | < 0.02 | < 0.02 | 0.18 |
25 | 79.9 | < 0.02 | < 0.02 | < 0.02 | 24.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 79.9 | < 0.02 | < 0.02 | 0.03 | 24.51 | 0.08 | < 0.02 | < 0.02 | 0.20 |
24 | 89.8 | < 0.02 | < 0.02 | 0.34 | 23.95 | 0.12 | < 0.02 | 0.03 | 0.22 |
22 | 99.7 | 193.33 | 35.546 | 6.80 | 23.78 | 0.53 | < 0.02 | 0.02 | 5.54 |
23 | 99.8 | < 0.02 | < 0.02 | < 0.02 | 23.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 110.6 | < 0.02 | < 0.02 | 2.37 | 23.11 | 0.27 | < 0.02 | 0.04 | 0.44 |
20 | 120.1 | < 0.02 | < 0.02 | 2.74 | 22.71 | 0.29 | < 0.02 | 0.03 | 0.42 |
19 | 130 | < 0.02 | < 0.02 | < 0.02 | 22.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 130.1 | < 0.02 | < 0.02 | 2.73 | 22.24 | 0.29 | < 0.02 | 0.03 | 0.39 |
17 | 140.5 | < 0.02 | < 0.02 | 3.51 | 21.79 | 0.34 | < 0.02 | 0.02 | 0.53 |
16 | 150 | < 0.02 | < 0.02 | 3.39 | 21.56 | 0.33 | < 0.02 | 0.02 | 0.49 |
15 | 159.7 | 186.75 | 35.757 | 3.29 | 21.23 | 0.32 | < 0.02 | 0.02 | 0.47 |
14 | 170.6 | < 0.02 | < 0.02 | 3.68 | 20.84 | 0.34 | < 0.02 | < 0.02 | 0.54 |
13 | 180.5 | < 0.02 | < 0.02 | 3.73 | 20.43 | 0.35 | < 0.02 | < 0.02 | 0.57 |
12 | 190 | < 0.02 | < 0.02 | 3.66 | 20.17 | 0.34 | < 0.02 | < 0.02 | 0.53 |
11 | 201 | < 0.02 | < 0.02 | 3.27 | 19.76 | 0.31 | < 0.02 | < 0.02 | 0.50 |
10 | 225 | < 0.02 | < 0.02 | 3.48 | 19.50 | 0.32 | < 0.02 | < 0.02 | 0.59 |
9 | 250 | < 0.02 | < 0.02 | 3.98 | 19.08 | 0.36 | < 0.02 | < 0.02 | 0.79 |
8 | 350.5 | < 0.02 | < 0.02 | 7.51 | 16.91 | 0.59 | < 0.02 | < 0.02 | 1.70 |
7 | 499.7 | 196.46 | 35.055 | 14.02 | 12.65 | 1.00 | < 0.02 | < 0.02 | 4.50 |
6 | 666.8 | < 0.02 | < 0.02 | 18.21 | 10.32 | 1.26 | < 0.02 | < 0.02 | 6.66 |
5 | 830.8 | < 0.02 | < 0.02 | 23.02 | 8.35 | 1.58 | < 0.02 | < 0.02 | 11.45 |
4 | 1000.1 | < 0.02 | 34.443 | 27.45 | 6.39 | 1.89 | < 0.02 | < 0.02 | 22.40 |
3 | 1165.2 | < 0.02 | < 0.02 | 30.30 | 5.41 | 2.09 | < 0.02 | < 0.02 | 36.52 |
2 | 1334.4 | < 0.02 | < 0.02 | 32.69 | 4.47 | 2.28 | < 0.02 | < 0.02 | 54.80 |
1 | 1517.3 | < 0.02 | 34.536 | 34.69 | 3.60 | 2.45 | < 0.02 | < 0.02 | 76.83 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |