Please login if you have access to particular applications.
Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 19
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-11 17:19 to 2018-04-11 19:16 UTC
Where: 34° 12.2' S 153° 27.2' E
Maximum Depth (m): 1501.8
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 9.2 | < 0.02 | < 0.02 | < 0.02 | 26.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 9.9 | 206.46 | 35.216 | 0.02 | 26.18 | 0.04 | < 0.02 | < 0.02 | 0.60 |
| 34 | 20.2 | < 0.02 | < 0.02 | 0.02 | 26.19 | 0.04 | < 0.02 | < 0.02 | 0.62 |
| 33 | 29.6 | < 0.02 | < 0.02 | < 0.02 | 26.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 30.3 | < 0.02 | < 0.02 | 0.02 | 26.17 | 0.04 | < 0.02 | < 0.02 | 0.69 |
| 31 | 39.3 | < 0.02 | < 0.02 | 0.02 | 26.02 | 0.03 | < 0.02 | < 0.02 | 0.72 |
| 30 | 49.6 | < 0.02 | < 0.02 | 0.05 | 26.01 | 0.04 | < 0.02 | 0.02 | 0.75 |
| 29 | 59.8 | < 0.02 | < 0.02 | < 0.02 | 25.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 60.1 | < 0.02 | < 0.02 | 0.68 | 25.71 | 0.10 | < 0.02 | 0.14 | 0.98 |
| 26 | 69.2 | < 0.02 | < 0.02 | 2.05 | 24.83 | 0.21 | < 0.02 | 0.22 | 1.30 |
| 27 | 69.7 | < 0.02 | < 0.02 | < 0.02 | 24.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 79.8 | < 0.02 | < 0.02 | 3.53 | 23.53 | 0.34 | < 0.02 | 0.16 | 1.41 |
| 23 | 89.8 | < 0.02 | < 0.02 | < 0.02 | 22.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 90 | < 0.02 | < 0.02 | 5.43 | 22.12 | 0.46 | < 0.02 | 0.08 | 1.70 |
| 22 | 100.3 | 183.04 | 35.324 | 13.02 | 21.64 | 0.94 | < 0.02 | 0.02 | 12.60 |
| 20 | 110.2 | < 0.02 | < 0.02 | 4.72 | 21.48 | 0.42 | < 0.02 | 0.02 | 1.33 |
| 21 | 110.3 | < 0.02 | < 0.02 | < 0.02 | 21.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 119.8 | < 0.02 | < 0.02 | 4.08 | 21.24 | 0.38 | < 0.02 | 0.02 | 1.19 |
| 18 | 130.1 | < 0.02 | < 0.02 | 3.99 | 20.95 | 0.37 | < 0.02 | 0.02 | 1.18 |
| 17 | 140.4 | < 0.02 | < 0.02 | 4.60 | 20.54 | 0.41 | < 0.02 | 0.02 | 1.32 |
| 16 | 150.1 | < 0.02 | < 0.02 | 4.79 | 20.27 | 0.42 | < 0.02 | 0.02 | 1.37 |
| 15 | 160.1 | 177.69 | 35.085 | 20.63 | 20.01 | 1.44 | < 0.02 | < 0.02 | 34.00 |
| 14 | 169.7 | < 0.02 | < 0.02 | 6.00 | 19.56 | 0.50 | < 0.02 | 0.02 | 1.77 |
| 13 | 180.2 | < 0.02 | < 0.02 | 7.19 | 19.00 | 0.59 | < 0.02 | 0.02 | 2.15 |
| 12 | 190.3 | < 0.02 | < 0.02 | 7.55 | 18.65 | 0.61 | < 0.02 | < 0.02 | 2.33 |
| 11 | 200 | < 0.02 | < 0.02 | 8.45 | 18.07 | 0.67 | < 0.02 | < 0.02 | 2.75 |
| 10 | 224.8 | < 0.02 | < 0.02 | 9.51 | 17.04 | 0.73 | < 0.02 | < 0.02 | 3.25 |
| 9 | 250.1 | < 0.02 | < 0.02 | 8.01 | 16.46 | 0.61 | < 0.02 | < 0.02 | 2.48 |
| 8 | 354.2 | < 0.02 | < 0.02 | 9.85 | 14.05 | 0.73 | < 0.02 | < 0.02 | 3.34 |
| 7 | 500.8 | 200.70 | 34.807 | 18.25 | 10.44 | 1.25 | < 0.02 | < 0.02 | 7.34 |
| 6 | 667.7 | < 0.02 | < 0.02 | 23.31 | 8.04 | 1.59 | < 0.02 | < 0.02 | 12.55 |
| 5 | 833 | < 0.02 | < 0.02 | 27.00 | 6.55 | 1.84 | < 0.02 | < 0.02 | 21.62 |
| 4 | 1006.1 | 189.41 | 34.454 | 30.46 | 5.37 | 2.09 | < 0.02 | < 0.02 | 38.16 |
| 3 | 1169.9 | < 0.02 | < 0.02 | 32.53 | 4.49 | 2.24 | < 0.02 | < 0.02 | 54.99 |
| 2 | 1333 | < 0.02 | < 0.02 | 34.03 | 3.88 | 2.37 | < 0.02 | < 0.02 | 69.83 |
| 1 | 1501.8 | < 0.02 | 34.563 | 35.22 | 3.31 | 2.46 | < 0.02 | < 0.02 | 85.50 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
| Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |