Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 18
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-11 13:02 to 2018-04-11 15:08 UTC
Where: 34° 13.1' S 153° 08.0' E
Maximum Depth (m): 1501.7
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 9.3 | < 0.02 | < 0.02 | < 0.02 | 23.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 9.8 | 220.31 | 35.385 | 0.03 | 23.45 | 0.08 | < 0.02 | < 0.02 | 0.63 |
34 | 10.3 | < 0.02 | < 0.02 | 0.02 | 23.45 | 0.07 | < 0.02 | < 0.02 | 0.60 |
33 | 20.3 | < 0.02 | < 0.02 | 0.02 | 23.45 | 0.07 | < 0.02 | < 0.02 | 0.57 |
32 | 20.7 | < 0.02 | < 0.02 | < 0.02 | 23.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 31.8 | < 0.02 | < 0.02 | 0.62 | 22.38 | 0.16 | 0.05 | 0.07 | 0.43 |
30 | 42.8 | < 0.02 | < 0.02 | 4.47 | 21.16 | 0.40 | 0.06 | 0.33 | 1.55 |
29 | 42.9 | < 0.02 | < 0.02 | < 0.02 | 21.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 52.2 | < 0.02 | < 0.02 | 4.56 | 20.63 | 0.43 | 0.17 | 0.38 | 1.48 |
27 | 59.9 | < 0.02 | < 0.02 | 5.51 | 19.88 | 0.49 | 0.19 | 0.41 | 1.81 |
26 | 60 | < 0.02 | < 0.02 | < 0.02 | 19.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 70.2 | 174.17 | 35.521 | 6.89 | 19.09 | 0.56 | < 0.02 | 0.36 | 2.45 |
24 | 80.2 | < 0.02 | < 0.02 | 7.11 | 18.57 | 0.57 | < 0.02 | 0.17 | 2.41 |
23 | 80.5 | < 0.02 | < 0.02 | < 0.02 | 18.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 90.2 | < 0.02 | < 0.02 | 12.01 | 18.02 | 0.87 | < 0.02 | 0.08 | 7.94 |
21 | 100.6 | < 0.02 | < 0.02 | 8.05 | 17.32 | 0.64 | < 0.02 | 0.07 | 2.72 |
20 | 110.2 | < 0.02 | < 0.02 | 9.56 | 16.15 | 0.72 | < 0.02 | 0.02 | 3.33 |
19 | 110.8 | < 0.02 | < 0.02 | 9.57 | 16.14 | 0.73 | < 0.02 | 0.02 | 3.31 |
18 | 119.8 | < 0.02 | < 0.02 | 10.35 | 15.50 | 0.77 | < 0.02 | 0.02 | 3.64 |
17 | 130.2 | < 0.02 | < 0.02 | 11.31 | 14.85 | 0.84 | < 0.02 | < 0.02 | 4.05 |
16 | 139.8 | < 0.02 | < 0.02 | 11.86 | 14.41 | 0.85 | < 0.02 | < 0.02 | 4.19 |
15 | 150.5 | < 0.02 | < 0.02 | 20.98 | 13.95 | 1.44 | < 0.02 | < 0.02 | 23.22 |
14 | 160.1 | < 0.02 | < 0.02 | 13.01 | 13.53 | 0.92 | < 0.02 | < 0.02 | 4.69 |
13 | 170 | < 0.02 | < 0.02 | 13.62 | 13.20 | 0.97 | < 0.02 | < 0.02 | 4.95 |
12 | 180 | < 0.02 | < 0.02 | 13.84 | 12.93 | 0.98 | < 0.02 | < 0.02 | 4.98 |
11 | 189.5 | < 0.02 | < 0.02 | 14.10 | 12.76 | 0.99 | < 0.02 | < 0.02 | 5.02 |
10 | 201.7 | < 0.02 | < 0.02 | 14.34 | 12.59 | 1.01 | < 0.02 | < 0.02 | 5.13 |
9 | 302 | 197.84 | 34.841 | 17.75 | 10.76 | 1.22 | < 0.02 | < 0.02 | 7.05 |
8 | 402.4 | < 0.02 | < 0.02 | 20.93 | 9.14 | 1.43 | < 0.02 | < 0.02 | 9.61 |
7 | 550.6 | 206.75 | 34.490 | 25.31 | 7.19 | 1.72 | < 0.02 | < 0.02 | 16.71 |
6 | 652.1 | < 0.02 | < 0.02 | 27.76 | 6.24 | 1.89 | < 0.02 | < 0.02 | 24.33 |
5 | 799.8 | < 0.02 | < 0.02 | 29.77 | 5.64 | 2.03 | < 0.02 | < 0.02 | 33.99 |
4 | 1001 | 180.33 | 34.466 | 32.20 | 4.63 | 2.22 | < 0.02 | < 0.02 | 51.88 |
3 | 1151.6 | < 0.02 | < 0.02 | 33.62 | 4.06 | 2.34 | < 0.02 | < 0.02 | 65.58 |
2 | 1299.5 | < 0.02 | < 0.02 | 34.76 | 3.57 | 2.43 | < 0.02 | < 0.02 | 78.28 |
1 | 1501.7 | 156.09 | 34.584 | 35.62 | 3.00 | 2.50 | < 0.02 | < 0.02 | 92.77 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |