Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 15
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-11 00:06 to 2018-04-11 01:00 UTC
Where: 34° 56.9' S 152° 29.2' E
Maximum Depth (m): 501.6
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
34 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 23.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 7.3 | 220.29 | 35.552 | 0.03 | 23.31 | 0.08 | 0.31 | < 0.02 | 0.56 |
35 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 23.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 14.6 | < 0.02 | < 0.02 | < 0.02 | 23.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 14.8 | < 0.02 | < 0.02 | 0.03 | 23.31 | 0.04 | < 0.02 | < 0.02 | 0.56 |
33 | 15.3 | < 0.02 | < 0.02 | < 0.02 | 23.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 19.8 | < 0.02 | < 0.02 | < 0.02 | 23.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 20 | 220.09 | 35.546 | 0.03 | 23.30 | 0.04 | < 0.02 | < 0.02 | 0.53 |
28 | 29.3 | < 0.02 | < 0.02 | 0.05 | 22.59 | 0.05 | < 0.02 | 0.02 | 0.38 |
27 | 29.4 | < 0.02 | < 0.02 | < 0.02 | 22.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 40 | < 0.02 | < 0.02 | < 0.02 | 21.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 40.1 | < 0.02 | < 0.02 | 0.04 | 21.91 | 0.07 | < 0.02 | < 0.02 | 0.49 |
26 | 40.3 | < 0.02 | < 0.02 | < 0.02 | 21.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 49.9 | < 0.02 | < 0.02 | 0.85 | 21.03 | 0.16 | 0.05 | 0.07 | 0.79 |
23 | 50 | < 0.02 | < 0.02 | < 0.02 | 21.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 59.7 | < 0.02 | < 0.02 | < 0.02 | 20.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 60 | < 0.02 | < 0.02 | 2.05 | 20.31 | 0.24 | 0.05 | 0.19 | 1.03 |
21 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 20.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 69.3 | < 0.02 | < 0.02 | < 0.02 | 19.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 70.2 | < 0.02 | < 0.02 | 3.08 | 19.63 | 0.30 | 0.02 | 0.28 | 1.21 |
16 | 79.8 | < 0.02 | < 0.02 | < 0.02 | 18.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 79.9 | < 0.02 | < 0.02 | 6.04 | 18.72 | 0.50 | < 0.02 | 0.18 | 2.03 |
15 | 79.9 | < 0.02 | < 0.02 | < 0.02 | 18.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 100.1 | < 0.02 | < 0.02 | < 0.02 | 17.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 100.3 | 186.11 | 35.525 | 7.29 | 17.37 | 0.58 | < 0.02 | 0.03 | 2.30 |
9 | 110.3 | < 0.02 | < 0.02 | < 0.02 | 16.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 110.3 | < 0.02 | < 0.02 | 7.99 | 16.97 | 0.62 | < 0.02 | 0.04 | 2.65 |
11 | 110.3 | < 0.02 | < 0.02 | < 0.02 | 16.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 131 | < 0.02 | < 0.02 | < 0.02 | 15.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 131.1 | < 0.02 | < 0.02 | 9.04 | 15.80 | 0.69 | < 0.02 | 0.03 | 3.03 |
5 | 163.3 | < 0.02 | < 0.02 | < 0.02 | 14.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 163.5 | 194.45 | 35.281 | 10.91 | 14.40 | 0.81 | < 0.02 | 0.03 | 3.83 |
3 | 331.6 | < 0.02 | < 0.02 | < 0.02 | 10.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 331.7 | 212.73 | 34.867 | 16.84 | 10.51 | 1.17 | < 0.02 | 0.02 | 6.18 |
2 | 501.4 | < 0.02 | < 0.02 | < 0.02 | 8.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 501.6 | 207.36 | 34.570 | 23.41 | 8.05 | 1.60 | < 0.02 | < 0.02 | 12.53 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |