Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 13
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-10 18:39 to 2018-04-10 19:37 UTC
Where: 34° 50.5' S 153° 01.8' E
Maximum Depth (m): 502.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 26.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 26.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.8 | 208.65 | 35.256 | 0.02 | 26.02 | 0.04 | < 0.02 | < 0.02 | 0.59 |
32 | 9.6 | < 0.02 | < 0.02 | 0.02 | 26.03 | 0.04 | < 0.02 | < 0.02 | 0.62 |
33 | 10 | < 0.02 | < 0.02 | < 0.02 | 26.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 19.4 | < 0.02 | < 0.02 | < 0.02 | 26.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 20.7 | 208.71 | 35.259 | 0.02 | 26.02 | 0.04 | < 0.02 | < 0.02 | 0.62 |
29 | 21.7 | < 0.02 | < 0.02 | < 0.02 | 26.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 30.3 | < 0.02 | < 0.02 | < 0.02 | 25.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 30.3 | < 0.02 | < 0.02 | 0.03 | 25.77 | 0.04 | < 0.02 | < 0.02 | 0.54 |
26 | 40.5 | < 0.02 | < 0.02 | 2.33 | 23.68 | 0.24 | 0.05 | 0.17 | 1.39 |
25 | 40.6 | < 0.02 | < 0.02 | < 0.02 | 23.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 40.6 | < 0.02 | < 0.02 | < 0.02 | 23.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 50.3 | < 0.02 | < 0.02 | < 0.02 | 22.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 50.3 | < 0.02 | < 0.02 | 11.33 | 22.36 | 0.82 | < 0.02 | 0.05 | 4.36 |
20 | 60.7 | < 0.02 | < 0.02 | 6.54 | 20.83 | 0.54 | < 0.02 | 0.05 | 1.94 |
21 | 60.7 | < 0.02 | < 0.02 | < 0.02 | 20.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 70.1 | < 0.02 | < 0.02 | < 0.02 | 20.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 70.2 | < 0.02 | < 0.02 | 6.42 | 20.15 | 0.52 | < 0.02 | 0.10 | 1.90 |
17 | 70.4 | < 0.02 | < 0.02 | < 0.02 | 20.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 79.9 | < 0.02 | < 0.02 | 5.69 | 19.59 | 0.48 | < 0.02 | 0.23 | 1.86 |
15 | 80.1 | < 0.02 | < 0.02 | < 0.02 | 19.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 99.5 | < 0.02 | < 0.02 | < 0.02 | 18.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 99.6 | < 0.02 | < 0.02 | < 0.02 | 18.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 100.1 | 200.89 | 35.578 | 4.22 | 18.45 | 0.39 | < 0.02 | 0.17 | 1.44 |
11 | 120.5 | < 0.02 | < 0.02 | < 0.02 | 17.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 120.6 | < 0.02 | < 0.02 | 6.62 | 17.30 | 0.54 | < 0.02 | 0.04 | 2.08 |
8 | 130.2 | < 0.02 | < 0.02 | 6.99 | 16.93 | 0.57 | < 0.02 | 0.03 | 2.16 |
9 | 130.4 | < 0.02 | < 0.02 | < 0.02 | 16.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 130.4 | < 0.02 | < 0.02 | < 0.02 | 16.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 160.9 | < 0.02 | < 0.02 | < 0.02 | 15.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 160.9 | 192.75 | 35.409 | 9.14 | 15.59 | 0.70 | < 0.02 | < 0.02 | 3.06 |
4 | 330.4 | 201.31 | 34.934 | 16.35 | 11.24 | 1.14 | < 0.02 | < 0.02 | 6.29 |
3 | 330.5 | < 0.02 | < 0.02 | < 0.02 | 11.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 502.2 | 205.60 | 34.631 | 22.24 | 8.60 | 1.53 | < 0.02 | < 0.02 | 11.00 |
1 | 502.2 | < 0.02 | < 0.02 | < 0.02 | 8.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |