Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 12
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-10 14:14 to 2018-04-10 16:20 UTC
Where: 34° 49.7' S 153° 11.6' E
Maximum Depth (m): 1500.4
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 8.5 | 207.62 | 35.299 | 0.02 | 26.22 | 0.05 | < 0.02 | < 0.02 | 0.59 |
35 | 9.3 | < 0.02 | < 0.02 | < 0.02 | 26.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 10.6 | < 0.02 | < 0.02 | 0.02 | 26.21 | 0.05 | < 0.02 | < 0.02 | 0.60 |
32 | 24.5 | < 0.02 | < 0.02 | < 0.02 | 26.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 24.7 | < 0.02 | < 0.02 | 0.02 | 26.22 | 0.05 | < 0.02 | < 0.02 | 0.61 |
31 | 31.4 | < 0.02 | < 0.02 | 0.02 | 26.22 | 0.05 | < 0.02 | < 0.02 | 0.64 |
30 | 41.2 | < 0.02 | < 0.02 | 0.05 | 25.83 | 0.06 | < 0.02 | < 0.02 | 0.48 |
29 | 49.6 | 201.97 | 35.386 | 0.32 | 25.42 | 0.10 | < 0.02 | 0.08 | 0.31 |
28 | 55 | < 0.02 | < 0.02 | 3.41 | 23.67 | 0.33 | < 0.02 | 0.23 | 1.43 |
27 | 55.4 | < 0.02 | < 0.02 | < 0.02 | 23.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 70.3 | < 0.02 | < 0.02 | 5.55 | 21.76 | 0.48 | < 0.02 | 0.13 | 1.71 |
25 | 80.2 | < 0.02 | < 0.02 | 6.39 | 21.10 | 0.53 | < 0.02 | 0.03 | 1.81 |
24 | 90.6 | < 0.02 | < 0.02 | 6.95 | 20.39 | 0.57 | < 0.02 | 0.02 | 2.04 |
23 | 100.3 | 163.09 | 35.633 | 7.04 | 20.20 | 0.59 | < 0.02 | 0.02 | 2.05 |
22 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 20.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
21 | 110.1 | < 0.02 | < 0.02 | 7.25 | 19.44 | 0.61 | < 0.02 | < 0.02 | 2.12 |
20 | 119.6 | < 0.02 | < 0.02 | 7.56 | 18.86 | 0.62 | < 0.02 | < 0.02 | 2.28 |
19 | 129.9 | 175.12 | 35.551 | 7.57 | 18.21 | 0.62 | < 0.02 | 0.03 | 2.46 |
18 | 140.4 | 187.16 | 35.575 | 6.22 | 18.16 | 0.52 | < 0.02 | 0.06 | 2.01 |
17 | 150.2 | < 0.02 | < 0.02 | 6.91 | 17.46 | 0.57 | < 0.02 | 0.05 | 2.32 |
15 | 159.9 | < 0.02 | < 0.02 | < 0.02 | 16.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 160 | < 0.02 | < 0.02 | 7.89 | 16.99 | 0.63 | < 0.02 | 0.04 | 2.60 |
14 | 169.5 | < 0.02 | < 0.02 | 7.95 | 16.82 | 0.63 | < 0.02 | 0.03 | 2.56 |
13 | 169.6 | < 0.02 | < 0.02 | < 0.02 | 16.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 179.8 | < 0.02 | < 0.02 | 7.63 | 16.34 | 0.61 | < 0.02 | 0.02 | 2.45 |
11 | 190.3 | < 0.02 | < 0.02 | 9.00 | 15.74 | 0.69 | < 0.02 | 0.02 | 3.05 |
10 | 199.3 | < 0.02 | < 0.02 | 9.11 | 15.41 | 0.70 | < 0.02 | 0.02 | 3.03 |
9 | 250.9 | < 0.02 | < 0.02 | 11.93 | 13.84 | 0.88 | < 0.02 | < 0.02 | 4.26 |
8 | 351.7 | 220.54 | 35.098 | 12.53 | 12.04 | 0.92 | < 0.02 | < 0.02 | 4.22 |
7 | 500.1 | 206.76 | 34.672 | 21.02 | 9.04 | 1.45 | < 0.02 | < 0.02 | 9.54 |
6 | 648.8 | < 0.02 | < 0.02 | 24.63 | 7.58 | 1.70 | < 0.02 | < 0.02 | 15.24 |
5 | 803.6 | < 0.02 | < 0.02 | 28.55 | 6.12 | 1.96 | < 0.02 | < 0.02 | 26.68 |
4 | 1007.9 | 181.91 | 34.468 | 31.78 | 4.77 | 2.22 | < 0.02 | < 0.02 | 48.53 |
3 | 1151.4 | < 0.02 | < 0.02 | 32.94 | 4.29 | 2.31 | < 0.02 | < 0.02 | 59.04 |
2 | 1300.9 | < 0.02 | < 0.02 | 34.35 | 3.62 | 2.44 | < 0.02 | < 0.02 | 76.40 |
1 | 1500.4 | 156.31 | 34.584 | 35.22 | 3.04 | 2.51 | < 0.02 | < 0.02 | 91.68 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |