Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-10 10:52 to 2018-04-10 12:53 UTC
Where: 34° 50.8' S 152° 53.0' E
Maximum Depth (m): 1502.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 5 | 222.04 | 35.615 | 0.02 | 22.96 | 0.05 | < 0.02 | < 0.02 | 0.46 |
35 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 22.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 15 | < 0.02 | < 0.02 | 0.02 | 22.97 | 0.05 | < 0.02 | < 0.02 | 0.43 |
33 | 15.9 | < 0.02 | < 0.02 | < 0.02 | 22.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 25.1 | < 0.02 | < 0.02 | 0.02 | 22.96 | 0.05 | < 0.02 | < 0.02 | 0.41 |
31 | 34.2 | < 0.02 | < 0.02 | 0.02 | 22.31 | 0.08 | < 0.02 | < 0.02 | 0.35 |
30 | 44.5 | < 0.02 | < 0.02 | 0.03 | 21.88 | 0.08 | < 0.02 | < 0.02 | 0.47 |
29 | 45.4 | < 0.02 | < 0.02 | < 0.02 | 21.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 56.2 | < 0.02 | < 0.02 | 0.98 | 20.81 | 0.17 | < 0.02 | 0.09 | 0.80 |
27 | 56.4 | < 0.02 | < 0.02 | < 0.02 | 20.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 58 | < 0.02 | < 0.02 | 1.67 | 20.53 | 0.22 | 0.02 | 0.14 | 0.99 |
25 | 72 | < 0.02 | < 0.02 | 8.89 | 19.02 | 0.67 | < 0.02 | 0.12 | 3.90 |
24 | 80.3 | < 0.02 | < 0.02 | 7.54 | 18.46 | 0.59 | < 0.02 | 0.07 | 2.84 |
23 | 90.9 | < 0.02 | < 0.02 | < 0.02 | 17.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 91.2 | < 0.02 | < 0.02 | 8.04 | 17.52 | 0.62 | < 0.02 | 0.06 | 2.73 |
21 | 101.4 | 185.57 | 35.358 | 10.72 | 16.72 | 0.80 | < 0.02 | 0.03 | 6.48 |
19 | 109.9 | < 0.02 | < 0.02 | < 0.02 | 16.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 110 | < 0.02 | < 0.02 | 9.06 | 16.33 | 0.69 | < 0.02 | 0.03 | 3.11 |
18 | 121 | < 0.02 | < 0.02 | 9.80 | 15.68 | 0.75 | < 0.02 | 0.02 | 3.35 |
17 | 131.3 | < 0.02 | < 0.02 | 21.13 | 15.46 | 1.47 | < 0.02 | < 0.02 | 28.12 |
16 | 140.6 | < 0.02 | < 0.02 | 22.99 | 15.10 | 1.61 | < 0.02 | < 0.02 | 41.09 |
15 | 150.3 | < 0.02 | < 0.02 | 10.51 | 14.80 | 0.79 | < 0.02 | 0.02 | 3.64 |
14 | 161.2 | < 0.02 | < 0.02 | 11.14 | 14.42 | 0.83 | < 0.02 | 0.02 | 3.93 |
13 | 170.1 | < 0.02 | < 0.02 | 11.07 | 14.28 | 0.82 | < 0.02 | 0.02 | 3.88 |
12 | 180.6 | < 0.02 | < 0.02 | 11.66 | 13.94 | 0.86 | < 0.02 | 0.02 | 4.09 |
11 | 191.3 | < 0.02 | < 0.02 | 11.81 | 13.70 | 0.86 | < 0.02 | < 0.02 | 4.06 |
10 | 205.1 | < 0.02 | < 0.02 | 12.61 | 13.21 | 0.92 | < 0.02 | < 0.02 | 4.34 |
9 | 303 | 204.58 | 34.923 | 16.32 | 11.08 | 1.14 | < 0.02 | < 0.02 | 5.94 |
8 | 402 | < 0.02 | < 0.02 | 20.16 | 9.15 | 1.39 | < 0.02 | < 0.02 | 8.17 |
7 | 501.8 | 205.16 | 34.558 | 23.73 | 7.93 | 1.63 | < 0.02 | < 0.02 | 13.31 |
6 | 650.9 | < 0.02 | < 0.02 | 27.24 | 6.56 | 1.88 | < 0.02 | < 0.02 | 22.54 |
5 | 801.4 | < 0.02 | < 0.02 | 29.95 | 5.52 | 2.07 | < 0.02 | < 0.02 | 35.29 |
4 | 1000.4 | 178.95 | 34.475 | 32.39 | 4.53 | 2.26 | < 0.02 | < 0.02 | 54.47 |
3 | 1150.6 | < 0.02 | < 0.02 | 33.94 | 3.95 | 2.40 | < 0.02 | < 0.02 | 73.39 |
2 | 1301 | < 0.02 | < 0.02 | 34.73 | 3.49 | 2.46 | < 0.02 | < 0.02 | 80.70 |
1 | 1502.5 | 162.60 | 34.605 | 35.30 | 2.90 | 2.51 | < 0.02 | < 0.02 | 91.58 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |