Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-10 01:33 to 2018-04-10 03:28 UTC
Where: 34° 58.2' S 152° 18.9' E
Maximum Depth (m): 1501.9
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
36 | 3.3 | 221.81 | 35.646 | 0.03 | 22.94 | 0.05 | < 0.02 | < 0.02 | 0.47 |
35 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 22.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 10.6 | < 0.02 | < 0.02 | 0.03 | 22.88 | 0.05 | < 0.02 | < 0.02 | 0.51 |
32 | 20.8 | < 0.02 | < 0.02 | < 0.02 | 22.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 21.1 | < 0.02 | < 0.02 | 0.03 | 22.81 | 0.05 | < 0.02 | < 0.02 | 0.48 |
31 | 31 | < 0.02 | < 0.02 | 0.03 | 22.79 | 0.04 | < 0.02 | < 0.02 | 0.46 |
29 | 40.6 | < 0.02 | < 0.02 | < 0.02 | 22.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 40.7 | < 0.02 | < 0.02 | 0.06 | 22.36 | 0.05 | < 0.02 | < 0.02 | 0.44 |
27 | 51.1 | < 0.02 | < 0.02 | < 0.02 | 21.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 51.1 | < 0.02 | < 0.02 | 2.20 | 21.10 | 0.25 | < 0.02 | 0.17 | 1.06 |
26 | 60.4 | < 0.02 | < 0.02 | 2.45 | 20.36 | 0.26 | < 0.02 | 0.31 | 0.99 |
25 | 71.1 | < 0.02 | < 0.02 | 1.97 | 19.87 | 0.23 | 0.04 | 0.19 | 0.80 |
24 | 80.7 | < 0.02 | < 0.02 | 0.84 | 19.42 | 0.16 | 0.07 | 0.12 | 0.50 |
23 | 80.8 | < 0.02 | < 0.02 | < 0.02 | 19.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 90.6 | < 0.02 | < 0.02 | 4.53 | 18.75 | 0.41 | < 0.02 | 0.13 | 1.45 |
21 | 100.6 | 194.72 | 35.047 | 17.19 | 17.92 | 1.20 | < 0.02 | 0.02 | 15.64 |
20 | 110.5 | < 0.02 | < 0.02 | 6.30 | 17.51 | 0.52 | < 0.02 | 0.05 | 1.92 |
19 | 120.5 | < 0.02 | < 0.02 | < 0.02 | 16.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 120.5 | < 0.02 | < 0.02 | 4.53 | 16.90 | 0.43 | < 0.02 | 0.07 | 1.41 |
17 | 130.6 | < 0.02 | < 0.02 | 18.04 | 16.08 | 1.26 | < 0.02 | 0.02 | 21.85 |
16 | 140.5 | < 0.02 | < 0.02 | 23.69 | 15.56 | 1.63 | < 0.02 | < 0.02 | 40.41 |
15 | 150.2 | < 0.02 | < 0.02 | 9.04 | 15.27 | 0.68 | < 0.02 | 0.02 | 2.90 |
14 | 160.5 | 202.39 | 35.387 | 8.82 | 15.14 | 0.67 | < 0.02 | < 0.02 | 2.77 |
13 | 170.6 | < 0.02 | < 0.02 | 9.06 | 14.97 | 0.68 | < 0.02 | < 0.02 | 2.89 |
12 | 180 | < 0.02 | < 0.02 | 9.45 | 14.72 | 0.71 | < 0.02 | < 0.02 | 3.05 |
11 | 190.5 | < 0.02 | < 0.02 | 9.77 | 14.46 | 0.73 | < 0.02 | < 0.02 | 3.18 |
10 | 200.5 | < 0.02 | < 0.02 | 10.17 | 14.25 | 0.75 | < 0.02 | 0.02 | 3.31 |
9 | 250.4 | < 0.02 | < 0.02 | 12.36 | 13.08 | 0.88 | < 0.02 | < 0.02 | 4.19 |
8 | 350.2 | < 0.02 | < 0.02 | 16.79 | 11.08 | 1.15 | < 0.02 | < 0.02 | 6.24 |
7 | 501.7 | 207.29 | 34.626 | 21.99 | 8.73 | 1.48 | < 0.02 | < 0.02 | 10.24 |
6 | 665.8 | < 0.02 | < 0.02 | 26.90 | 6.80 | 1.81 | < 0.02 | < 0.02 | 20.13 |
5 | 830.4 | < 0.02 | < 0.02 | 30.35 | 5.53 | 2.06 | < 0.02 | < 0.02 | 35.30 |
4 | 1001.4 | 178.66 | 34.472 | 32.93 | 4.53 | 2.25 | < 0.02 | < 0.02 | 54.24 |
3 | 1166.2 | < 0.02 | < 0.02 | 34.37 | 3.93 | 2.36 | 0.02 | < 0.02 | 67.98 |
2 | 1330.2 | < 0.02 | < 0.02 | 35.54 | 3.41 | 2.45 | 0.02 | < 0.02 | 80.38 |
1 | 1501.9 | 158.23 | 34.593 | 36.05 | 2.97 | 2.46 | 0.02 | < 0.02 | 90.22 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |