Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 8
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-09 20:32 to 2018-04-09 22:32 UTC
Where: 35° 02.9' S 152° 02.8' E
Maximum Depth (m): 1502.6
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 23.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4.4 | 217.91 | 35.710 | 0.03 | 23.17 | 0.05 | < 0.02 | < 0.02 | 0.43 |
34 | 10.3 | < 0.02 | < 0.02 | 0.03 | 23.17 | 0.04 | < 0.02 | < 0.02 | 0.41 |
33 | 20.8 | < 0.02 | < 0.02 | 0.03 | 23.18 | 0.04 | < 0.02 | < 0.02 | 0.41 |
32 | 30.3 | < 0.02 | < 0.02 | 0.03 | 23.18 | 0.04 | < 0.02 | < 0.02 | 0.44 |
31 | 30.4 | < 0.02 | < 0.02 | < 0.02 | 23.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 40.7 | < 0.02 | < 0.02 | 0.03 | 23.18 | 0.04 | < 0.02 | < 0.02 | 0.43 |
29 | 50.5 | < 0.02 | < 0.02 | 0.04 | 23.17 | 0.05 | < 0.02 | < 0.02 | 0.43 |
28 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 23.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 60.9 | < 0.02 | < 0.02 | 0.27 | 22.57 | 0.09 | 0.02 | 0.08 | 0.52 |
25 | 70.6 | < 0.02 | < 0.02 | < 0.02 | 21.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 70.7 | < 0.02 | < 0.02 | 1.78 | 21.39 | 0.24 | < 0.02 | 0.38 | 0.76 |
24 | 80.8 | < 0.02 | < 0.02 | 3.83 | 20.50 | 0.35 | < 0.02 | 0.11 | 1.00 |
23 | 90.9 | < 0.02 | < 0.02 | 4.30 | 20.12 | 0.38 | < 0.02 | 0.09 | 1.11 |
22 | 100.4 | 186.26 | 35.704 | 4.91 | 19.57 | 0.41 | < 0.02 | 0.04 | 1.21 |
21 | 100.5 | < 0.02 | < 0.02 | 5.08 | 19.57 | 0.42 | < 0.02 | 0.03 | 1.31 |
20 | 110.6 | < 0.02 | < 0.02 | 5.15 | 19.13 | 0.44 | < 0.02 | 0.02 | 1.34 |
19 | 120.4 | < 0.02 | < 0.02 | 5.64 | 18.43 | 0.47 | < 0.02 | 0.02 | 1.56 |
17 | 131.2 | < 0.02 | < 0.02 | < 0.02 | 18.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 131.3 | < 0.02 | < 0.02 | 5.99 | 18.05 | 0.49 | < 0.02 | < 0.02 | 1.69 |
16 | 139.7 | < 0.02 | < 0.02 | 6.61 | 17.69 | 0.53 | < 0.02 | < 0.02 | 1.92 |
15 | 150.1 | < 0.02 | < 0.02 | 7.16 | 17.37 | 0.57 | < 0.02 | 0.02 | 2.09 |
14 | 160.2 | 189.98 | 35.499 | 7.50 | 16.94 | 0.59 | < 0.02 | < 0.02 | 2.26 |
13 | 168.8 | < 0.02 | < 0.02 | 8.08 | 16.53 | 0.63 | < 0.02 | < 0.02 | 2.46 |
12 | 179.6 | < 0.02 | < 0.02 | 8.45 | 16.30 | 0.65 | < 0.02 | < 0.02 | 2.60 |
11 | 189.9 | < 0.02 | < 0.02 | 8.87 | 15.95 | 0.68 | < 0.02 | < 0.02 | 2.77 |
10 | 199.9 | < 0.02 | < 0.02 | 9.15 | 15.66 | 0.70 | < 0.02 | < 0.02 | 2.97 |
9 | 250.9 | < 0.02 | < 0.02 | 10.42 | 14.59 | 0.78 | < 0.02 | < 0.02 | 3.42 |
8 | 349.7 | < 0.02 | < 0.02 | 12.30 | 12.69 | 0.90 | < 0.02 | < 0.02 | 4.22 |
7 | 450.8 | 209.32 | 34.855 | 17.13 | 10.56 | 1.20 | < 0.02 | < 0.02 | 6.35 |
6 | 665.6 | < 0.02 | < 0.02 | 24.11 | 7.89 | 1.66 | < 0.02 | < 0.02 | 13.91 |
5 | 830.5 | < 0.02 | < 0.02 | 28.41 | 6.20 | 1.96 | < 0.02 | < 0.02 | 26.58 |
4 | 1000.4 | 185.80 | 34.461 | 31.28 | 5.03 | 2.17 | < 0.02 | < 0.02 | 43.47 |
3 | 1166 | < 0.02 | < 0.02 | 33.15 | 4.24 | 2.31 | < 0.02 | < 0.02 | 59.23 |
2 | 1331.2 | < 0.02 | < 0.02 | 34.83 | 3.50 | 2.46 | < 0.02 | < 0.02 | 79.73 |
1 | 1502.6 | 156.69 | 34.581 | 35.53 | 3.04 | 2.51 | < 0.02 | < 0.02 | 91.00 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |