Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-08 16:11 to 2018-04-08 18:22 UTC
Where: 38° 04.7' S 151° 24.1' E
Maximum Depth (m): 1503.2
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 20.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5.1 | 229.36 | 35.867 | 0.13 | 20.37 | 0.11 | 0.04 | 0.03 | 0.27 |
34 | 10.1 | < 0.02 | < 0.02 | 0.14 | 20.37 | 0.11 | 0.05 | 0.03 | 0.34 |
33 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 20.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 20.1 | < 0.02 | < 0.02 | 0.14 | 20.37 | 0.10 | 0.07 | 0.03 | 0.35 |
31 | 31.3 | < 0.02 | < 0.02 | 0.15 | 20.36 | 0.10 | 0.05 | 0.03 | 0.32 |
30 | 40.9 | < 0.02 | < 0.02 | 0.17 | 20.33 | 0.10 | 0.08 | 0.03 | 0.29 |
29 | 41.1 | < 0.02 | < 0.02 | < 0.02 | 20.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 50 | < 0.02 | < 0.02 | < 0.02 | 20.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 50.2 | < 0.02 | < 0.02 | 0.19 | 20.33 | 0.10 | 0.11 | 0.03 | 0.31 |
26 | 59.9 | < 0.02 | < 0.02 | 0.20 | 20.33 | 0.10 | 0.12 | 0.03 | 0.31 |
25 | 69.5 | < 0.02 | < 0.02 | 0.23 | 20.33 | 0.11 | 0.13 | 0.04 | 0.32 |
24 | 80.4 | < 0.02 | < 0.02 | 0.33 | 20.31 | 0.11 | 0.12 | 0.05 | 0.35 |
23 | 89.8 | < 0.02 | < 0.02 | < 0.02 | 20.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 90 | < 0.02 | < 0.02 | 0.66 | 20.25 | 0.14 | 0.09 | 0.08 | 0.40 |
21 | 100.5 | 223.17 | 35.859 | 0.76 | 20.23 | 0.14 | 0.07 | 0.10 | 0.40 |
20 | 110.5 | < 0.02 | < 0.02 | 0.90 | 20.21 | 0.15 | 0.06 | 0.11 | 0.41 |
19 | 120.5 | < 0.02 | < 0.02 | 1.40 | 20.11 | 0.18 | 0.02 | 0.14 | 0.51 |
18 | 130.3 | < 0.02 | < 0.02 | 1.62 | 20.03 | 0.18 | < 0.02 | 0.14 | 0.48 |
17 | 130.5 | < 0.02 | < 0.02 | < 0.02 | 20.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 140.5 | < 0.02 | < 0.02 | 2.11 | 19.87 | 0.21 | < 0.02 | 0.09 | 0.59 |
15 | 150.2 | < 0.02 | < 0.02 | 2.35 | 19.76 | 0.24 | < 0.02 | 0.06 | 0.69 |
14 | 160.6 | 210.89 | 35.796 | 2.59 | 19.66 | 0.26 | < 0.02 | 0.05 | 0.76 |
13 | 169.8 | < 0.02 | < 0.02 | 2.84 | 19.53 | 0.28 | < 0.02 | 0.04 | 0.80 |
12 | 180.4 | < 0.02 | < 0.02 | 3.17 | 19.33 | 0.30 | < 0.02 | 0.03 | 0.87 |
11 | 190.1 | < 0.02 | < 0.02 | 3.26 | 19.30 | 0.31 | < 0.02 | 0.03 | 0.91 |
10 | 200.6 | < 0.02 | < 0.02 | 3.31 | 19.27 | 0.32 | < 0.02 | 0.03 | 0.93 |
9 | 250.5 | < 0.02 | < 0.02 | 3.69 | 19.02 | 0.34 | < 0.02 | 0.02 | 1.04 |
8 | 352 | < 0.02 | < 0.02 | 4.97 | 17.73 | 0.42 | < 0.02 | 0.02 | 1.32 |
7 | 501.6 | 211.00 | 35.476 | 7.59 | 15.46 | 0.59 | < 0.02 | < 0.02 | 2.32 |
6 | 664.6 | < 0.02 | < 0.02 | 9.77 | 13.90 | 0.74 | < 0.02 | < 0.02 | 3.16 |
5 | 830.6 | < 0.02 | < 0.02 | 18.39 | 10.08 | 1.28 | < 0.02 | < 0.02 | 7.38 |
4 | 1000 | 202.90 | 34.538 | 24.55 | 7.73 | 1.69 | < 0.02 | < 0.02 | 15.12 |
3 | 1165.5 | < 0.02 | < 0.02 | 28.77 | 6.07 | 1.98 | < 0.02 | < 0.02 | 28.66 |
2 | 1331.5 | < 0.02 | < 0.02 | 31.88 | 4.82 | 2.22 | < 0.02 | < 0.02 | 48.33 |
1 | 1503.2 | 169.01 | 34.521 | 33.90 | 3.89 | 2.39 | < 0.02 | < 0.02 | 68.53 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |