Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-08 12:14 to 2018-04-08 14:24 UTC
Where: 37° 47.1' S 151° 23.3' E
Maximum Depth (m): 1500.6
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 20.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 4.8 | 229.66 | 35.888 | 0.03 | 20.47 | 0.09 | < 0.02 | < 0.02 | 0.40 |
34 | 10.4 | < 0.02 | < 0.02 | 0.04 | 20.47 | 0.08 | < 0.02 | < 0.02 | 0.41 |
33 | 20.5 | < 0.02 | < 0.02 | 0.03 | 20.45 | 0.07 | 0.05 | < 0.02 | 0.36 |
32 | 30.6 | < 0.02 | < 0.02 | 0.03 | 20.43 | 0.08 | < 0.02 | < 0.02 | 0.40 |
31 | 30.9 | < 0.02 | < 0.02 | < 0.02 | 20.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 39.7 | < 0.02 | < 0.02 | 0.04 | 20.41 | 0.08 | < 0.02 | < 0.02 | 0.39 |
29 | 50.8 | < 0.02 | < 0.02 | < 0.02 | 20.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 50.8 | < 0.02 | < 0.02 | 0.04 | 20.41 | 0.08 | 0.02 | < 0.02 | 0.39 |
27 | 60.8 | < 0.02 | < 0.02 | 0.05 | 20.41 | 0.09 | 0.03 | < 0.02 | 0.38 |
26 | 70.3 | < 0.02 | < 0.02 | 0.06 | 20.41 | 0.09 | 0.07 | < 0.02 | 0.38 |
24 | 80.7 | < 0.02 | < 0.02 | 0.07 | 20.41 | 0.09 | 0.05 | 0.02 | 0.39 |
25 | 80.8 | < 0.02 | < 0.02 | < 0.02 | 20.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 91.2 | < 0.02 | < 0.02 | 0.09 | 20.41 | 0.09 | 0.06 | 0.02 | 0.37 |
22 | 100.9 | < 0.02 | < 0.02 | 0.62 | 20.33 | 0.12 | 0.08 | 0.06 | 0.46 |
21 | 111 | < 0.02 | < 0.02 | < 0.02 | 19.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 111.1 | < 0.02 | < 0.02 | 2.66 | 19.70 | 0.25 | < 0.02 | 0.04 | 0.83 |
19 | 120.9 | < 0.02 | < 0.02 | 2.74 | 19.63 | 0.26 | < 0.02 | 0.02 | 0.86 |
18 | 131 | < 0.02 | < 0.02 | 2.74 | 19.61 | 0.27 | < 0.02 | 0.03 | 0.89 |
16 | 140.7 | < 0.02 | < 0.02 | 2.74 | 19.58 | 0.27 | 0.02 | 0.02 | 0.91 |
17 | 140.8 | < 0.02 | < 0.02 | < 0.02 | 19.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 151.7 | 210.02 | 35.797 | 2.74 | 19.57 | 0.27 | < 0.02 | 0.02 | 0.94 |
14 | 161.4 | < 0.02 | < 0.02 | 2.75 | 19.56 | 0.27 | < 0.02 | 0.02 | 0.93 |
13 | 171.4 | < 0.02 | < 0.02 | 2.78 | 19.54 | 0.27 | < 0.02 | 0.02 | 0.93 |
12 | 179.4 | < 0.02 | < 0.02 | 2.82 | 19.52 | 0.27 | < 0.02 | 0.02 | 0.92 |
11 | 190.8 | < 0.02 | < 0.02 | 2.87 | 19.49 | 0.27 | < 0.02 | 0.02 | 0.88 |
10 | 202.1 | < 0.02 | < 0.02 | 2.97 | 19.44 | 0.27 | < 0.02 | < 0.02 | 0.91 |
9 | 304.7 | 213.09 | 35.718 | 3.89 | 18.27 | 0.35 | < 0.02 | < 0.02 | 1.22 |
8 | 402.1 | < 0.02 | < 0.02 | 6.56 | 16.32 | 0.53 | < 0.02 | < 0.02 | 2.08 |
7 | 500.6 | 226.57 | 35.615 | 5.61 | 15.66 | 0.48 | < 0.02 | < 0.02 | 1.91 |
6 | 650.2 | < 0.02 | < 0.02 | 10.72 | 13.08 | 0.80 | < 0.02 | < 0.02 | 3.60 |
5 | 781.6 | < 0.02 | < 0.02 | 17.38 | 10.56 | 1.22 | 0.02 | < 0.02 | 6.73 |
4 | 900.8 | < 0.02 | < 0.02 | 22.12 | 8.57 | 1.53 | < 0.02 | < 0.02 | 10.70 |
3 | 1100.8 | 198.62 | 34.474 | 27.39 | 6.64 | 1.88 | < 0.02 | < 0.02 | 22.82 |
2 | 1331.2 | < 0.02 | < 0.02 | 31.75 | 4.88 | 2.21 | < 0.02 | < 0.02 | 47.30 |
1 | 1500.6 | 170.92 | 34.514 | 33.66 | 4.02 | 2.37 | < 0.02 | < 0.02 | 65.38 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |