Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-08 07:56 to 2018-04-08 09:53 UTC
Where: 37° 29.9' S 151° 20.1' E
Maximum Depth (m): 1504.8
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 4.5 | < 0.02 | < 0.02 | 0.08 | 20.61 | 0.11 | 0.03 | < 0.02 | 0.32 |
36 | 4.6 | 229.71 | 35.880 | 0.12 | 20.61 | 0.22 | 1.00 | 0.03 | 0.33 |
34 | 10.7 | < 0.02 | < 0.02 | < 0.02 | 20.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 20.9 | < 0.02 | < 0.02 | 0.07 | 20.47 | 0.11 | 0.04 | 0.02 | 0.32 |
31 | 29.3 | < 0.02 | < 0.02 | < 0.02 | 20.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 29.4 | < 0.02 | < 0.02 | 0.08 | 20.46 | 0.11 | 0.04 | 0.02 | 0.34 |
29 | 41.2 | < 0.02 | < 0.02 | < 0.02 | 20.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 41.5 | < 0.02 | < 0.02 | 0.09 | 20.45 | 0.11 | 0.05 | 0.02 | 0.33 |
28 | 50.9 | < 0.02 | < 0.02 | 0.09 | 20.45 | 0.11 | 0.06 | 0.02 | 0.36 |
27 | 51 | < 0.02 | < 0.02 | < 0.02 | 20.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 59.9 | < 0.02 | < 0.02 | 0.11 | 20.45 | 0.11 | 0.09 | 0.03 | 0.37 |
25 | 71.1 | < 0.02 | < 0.02 | 0.11 | 20.45 | 0.11 | 0.09 | 0.03 | 0.36 |
23 | 80.8 | < 0.02 | < 0.02 | < 0.02 | 20.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 80.9 | < 0.02 | < 0.02 | 0.11 | 20.45 | 0.10 | 0.10 | 0.03 | 0.33 |
22 | 89.4 | < 0.02 | < 0.02 | 0.12 | 20.45 | 0.10 | 0.10 | 0.02 | 0.33 |
21 | 100.7 | 227.03 | 35.865 | 0.42 | 20.43 | 0.12 | 0.09 | 0.05 | 0.38 |
20 | 111.2 | < 0.02 | < 0.02 | 2.80 | 19.72 | 0.28 | < 0.02 | 0.06 | 0.85 |
19 | 111.3 | < 0.02 | < 0.02 | < 0.02 | 19.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 121.1 | < 0.02 | < 0.02 | 3.02 | 19.60 | 0.30 | < 0.02 | 0.03 | 0.92 |
17 | 131.2 | < 0.02 | < 0.02 | 2.99 | 19.57 | 0.30 | < 0.02 | 0.02 | 0.93 |
16 | 140.1 | < 0.02 | < 0.02 | 3.00 | 19.53 | 0.30 | < 0.02 | 0.02 | 0.96 |
15 | 150.2 | < 0.02 | < 0.02 | 3.09 | 19.49 | 0.31 | < 0.02 | 0.03 | 0.96 |
14 | 161 | < 0.02 | < 0.02 | 3.21 | 19.43 | 0.32 | < 0.02 | 0.02 | 0.97 |
13 | 171.2 | < 0.02 | < 0.02 | 3.40 | 19.34 | 0.32 | < 0.02 | 0.02 | 0.97 |
12 | 180.5 | < 0.02 | < 0.02 | 3.59 | 19.27 | 0.34 | < 0.02 | 0.02 | 1.02 |
11 | 191.6 | < 0.02 | < 0.02 | 3.83 | 19.15 | 0.35 | < 0.02 | 0.02 | 1.05 |
10 | 199.6 | 201.25 | 35.713 | 4.17 | 18.99 | 0.37 | < 0.02 | < 0.02 | 1.14 |
9 | 300.5 | < 0.02 | < 0.02 | 5.78 | 17.22 | 0.50 | < 0.02 | < 0.02 | 1.75 |
8 | 399.9 | 225.38 | 35.556 | 5.91 | 15.50 | 0.51 | < 0.02 | < 0.02 | 1.96 |
7 | 500.1 | < 0.02 | < 0.02 | 9.78 | 13.63 | 0.75 | < 0.02 | < 0.02 | 3.21 |
6 | 651 | < 0.02 | < 0.02 | 14.59 | 11.15 | 1.04 | < 0.02 | < 0.02 | 4.96 |
5 | 831.1 | < 0.02 | < 0.02 | 21.83 | 8.65 | 1.50 | < 0.02 | < 0.02 | 10.22 |
4 | 1001.1 | 199.83 | 34.507 | 26.38 | 7.06 | 1.81 | < 0.02 | < 0.02 | 19.08 |
3 | 1168 | < 0.02 | < 0.02 | 29.63 | 5.66 | 2.05 | < 0.02 | < 0.02 | 33.20 |
2 | 1333.4 | < 0.02 | < 0.02 | 32.28 | 4.62 | 2.25 | < 0.02 | < 0.02 | 51.05 |
1 | 1504.8 | 166.44 | 34.527 | 34.28 | 3.73 | 2.41 | < 0.02 | < 0.02 | 71.96 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |