Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-07 04:32 to 2018-04-07 06:23 UTC
Where: 39° 03.9' S 151° 30.1' E
Maximum Depth (m): 1509.5
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
31 | 4.8 | 234.55 | 35.766 | < 0.02 | 19.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 19.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
35 | 5 | < 0.02 | < 0.02 | < 0.02 | 19.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 5 | < 0.02 | < 0.02 | 0.04 | 19.79 | 0.10 | < 0.02 | < 0.02 | 0.32 |
34 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 19.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
33 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 19.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
29 | 19.7 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 20.2 | < 0.02 | < 0.02 | 0.04 | 19.61 | 0.10 | < 0.02 | < 0.02 | 0.31 |
27 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 19.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 50.2 | < 0.02 | < 0.02 | 0.05 | 19.25 | 0.10 | 0.02 | 0.02 | 0.34 |
26 | 80.3 | < 0.02 | < 0.02 | < 0.02 | 18.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
25 | 80.3 | < 0.02 | < 0.02 | 0.47 | 18.86 | 0.14 | 0.06 | 0.10 | 0.43 |
24 | 100.9 | < 0.02 | < 0.02 | 0.94 | 17.98 | 0.23 | 0.43 | 0.19 | 0.60 |
23 | 101.1 | 234.58 | 35.647 | 0.95 | 18.00 | 0.23 | 0.43 | 0.19 | 0.61 |
21 | 120.7 | < 0.02 | < 0.02 | 3.50 | 17.10 | 0.39 | 0.18 | 0.42 | 1.44 |
22 | 120.7 | < 0.02 | < 0.02 | < 0.02 | 17.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 160.8 | < 0.02 | < 0.02 | < 0.02 | 15.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 160.9 | 213.41 | 35.422 | 7.83 | 15.24 | 0.63 | < 0.02 | 0.06 | 2.65 |
18 | 200.9 | < 0.02 | < 0.02 | < 0.02 | 14.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 200.9 | < 0.02 | < 0.02 | 7.82 | 14.81 | 0.62 | < 0.02 | 0.03 | 2.38 |
16 | 249.6 | < 0.02 | < 0.02 | < 0.02 | 13.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 249.6 | < 0.02 | < 0.02 | 10.42 | 13.60 | 0.78 | < 0.02 | 0.02 | 3.30 |
13 | 301.6 | < 0.02 | < 0.02 | 12.51 | 12.40 | 0.90 | < 0.02 | 0.02 | 4.05 |
14 | 301.7 | < 0.02 | < 0.02 | < 0.02 | 12.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 400.9 | < 0.02 | < 0.02 | 17.19 | 10.41 | 1.19 | < 0.02 | < 0.02 | 6.17 |
12 | 401 | < 0.02 | < 0.02 | < 0.02 | 10.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 500.9 | 215.70 | 34.652 | < 0.02 | 8.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
9 | 501.1 | < 0.02 | < 0.02 | 20.64 | 8.95 | 1.42 | < 0.02 | < 0.02 | 8.48 |
8 | 751.4 | < 0.02 | < 0.02 | < 0.02 | 6.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 751.5 | < 0.02 | < 0.02 | 27.50 | 6.56 | 1.88 | < 0.02 | < 0.02 | 22.77 |
5 | 1003.6 | 188.97 | 34.444 | 31.15 | 5.07 | 2.15 | < 0.02 | < 0.02 | 41.29 |
6 | 1003.7 | < 0.02 | < 0.02 | < 0.02 | 5.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 1253.4 | < 0.02 | < 0.02 | 34.31 | 3.72 | 2.40 | < 0.02 | < 0.02 | 71.30 |
4 | 1253.5 | < 0.02 | < 0.02 | < 0.02 | 3.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 1506.8 | 159.61 | 34.583 | 35.38 | 2.99 | 2.49 | < 0.02 | < 0.02 | 87.87 |
2 | 1509.5 | < 0.02 | < 0.02 | < 0.02 | 2.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |