Deployment Details
Survey: - IN2018_T01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-06 03:18 to 2018-04-06 04:15 UTC
Where: 42° 36.0' S 148° 14.4' E
Maximum Depth (m): 80.7
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
35 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 16.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
36 | 3.1 | 246.51 | 35.513 | 0.57 | 16.75 | 0.17 | < 0.02 | 0.23 | 0.31 |
33 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
34 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
31 | 8 | < 0.02 | < 0.02 | < 0.02 | 16.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 8.1 | 246.50 | 35.515 | 0.57 | 16.75 | 0.17 | < 0.02 | 0.23 | 0.34 |
29 | 9.8 | < 0.02 | < 0.02 | < 0.02 | 16.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 10 | < 0.02 | < 0.02 | < 0.02 | 16.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
27 | 15.4 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
28 | 15.4 | < 0.02 | < 0.02 | < 0.02 | 16.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
26 | 20.5 | 245.96 | 35.508 | 0.60 | 16.74 | 0.18 | < 0.02 | 0.25 | 0.35 |
25 | 20.5 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 25 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
23 | 25 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
22 | 30.1 | 244.80 | 35.510 | 0.67 | 16.73 | 0.18 | 0.02 | 0.27 | 0.34 |
21 | 30.4 | < 0.02 | < 0.02 | < 0.02 | 16.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
19 | 34.8 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
20 | 34.9 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 40.6 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
17 | 40.7 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
15 | 45.4 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
16 | 45.5 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
14 | 50 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
13 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
11 | 55.2 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 55.2 | < 0.02 | < 0.02 | < 0.02 | 16.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
10 | 60.4 | 243.06 | 35.514 | 0.94 | 16.73 | 0.19 | 0.02 | 0.35 | 0.38 |
9 | 60.6 | < 0.02 | < 0.02 | < 0.02 | 16.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
7 | 65 | < 0.02 | < 0.02 | < 0.02 | 16.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
8 | 65.2 | < 0.02 | < 0.02 | < 0.02 | 16.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 70.2 | < 0.02 | < 0.02 | < 0.02 | 16.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
5 | 70.4 | < 0.02 | < 0.02 | < 0.02 | 16.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
3 | 75.1 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
4 | 75.3 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 16.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1 | 80.7 | 236.25 | 35.451 | 2.36 | 16.22 | 0.28 | < 0.02 | 0.66 | 0.74 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |