Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 14
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-05-06 03:44 to 2018-05-06 04:29 UTC
Where: 27° 19.0' S 153° 54.0' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2036 | 10.5 | < 0.02 | < 0.02 | < 0.02 | 25.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 25.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 10.7 | 213.61 | 35.329 | 0.06 | 25.00 | 0.06 | < 0.02 | < 0.02 | 0.36 |
2034 | 11 | < 0.02 | < 0.02 | < 0.02 | 25.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 40.8 | < 0.02 | < 0.02 | < 0.02 | 25.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 41 | 211.74 | 35.329 | 0.06 | 25.00 | 0.06 | < 0.02 | < 0.02 | 0.34 |
2030 | 41.1 | < 0.02 | < 0.02 | < 0.02 | 25.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 80.7 | < 0.02 | < 0.02 | < 0.02 | 20.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 80.8 | 167.26 | 35.623 | 6.76 | 20.43 | 0.57 | < 0.02 | 0.05 | 1.75 |
2028 | 80.8 | < 0.02 | < 0.02 | < 0.02 | 20.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2024 | 140.3 | < 0.02 | < 0.02 | < 0.02 | 18.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 140.4 | < 0.02 | < 0.02 | < 0.02 | 18.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 140.4 | 168.19 | 35.528 | 8.25 | 18.40 | 0.67 | < 0.02 | 0.02 | 2.35 |
2021 | 199.8 | < 0.02 | < 0.02 | < 0.02 | 16.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 199.9 | < 0.02 | < 0.02 | < 0.02 | 16.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 199.9 | 169.85 | 35.358 | 10.34 | 16.46 | 0.81 | < 0.02 | < 0.02 | 3.41 |
2016 | 252.7 | < 0.02 | < 0.02 | < 0.02 | 15.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 252.7 | < 0.02 | < 0.02 | < 0.02 | 15.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 252.9 | < 0.02 | < 0.02 | < 0.02 | 15.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 252.9 | < 0.02 | < 0.02 | < 0.02 | 15.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 253.1 | < 0.02 | < 0.02 | < 0.02 | 15.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 253.3 | 179.00 | 35.250 | 11.44 | 14.99 | 0.87 | < 0.02 | < 0.02 | 3.82 |
1214 | 298.4 | 186.33 | 35.096 | 13.71 | 13.45 | 1.00 | < 0.02 | < 0.02 | 4.93 |
2013 | 298.5 | < 0.02 | < 0.02 | < 0.02 | 13.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 298.6 | < 0.02 | < 0.02 | < 0.02 | 13.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 351.2 | < 0.02 | < 0.02 | < 0.02 | 12.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 351.3 | 186.95 | 35.015 | 14.93 | 12.66 | 1.08 | < 0.02 | < 0.02 | 5.57 |
2010 | 351.4 | < 0.02 | < 0.02 | < 0.02 | 12.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 426.3 | < 0.02 | < 0.02 | < 0.02 | 10.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2006 | 426.4 | < 0.02 | < 0.02 | < 0.02 | 10.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 426.5 | 202.54 | 34.834 | 17.69 | 10.86 | 1.24 | < 0.02 | < 0.02 | 6.86 |
12003 | 500 | < 0.02 | < 0.02 | < 0.02 | 9.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 500 | 201.96 | 34.688 | 20.41 | 9.47 | 1.41 | < 0.02 | < 0.02 | 8.96 |
12004 | 500.1 | < 0.02 | < 0.02 | < 0.02 | 9.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12001 | 567.7 | < 0.02 | < 0.02 | < 0.02 | 9.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12002 | 567.9 | 202.40 | 34.680 | 20.53 | 9.42 | 1.43 | < 0.02 | < 0.02 | 9.10 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |