Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 13
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-05-05 08:32 to 2018-05-05 10:28 UTC
Where: 27° 18.6' S 154° 01.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 10.2 | 214.02 | 35.287 | 0.04 | 24.62 | 0.07 | < 0.02 | < 0.02 | 0.31 |
2036 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 24.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 40.7 | < 0.02 | < 0.02 | < 0.02 | 24.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 40.7 | < 0.02 | < 0.02 | < 0.02 | 24.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 40.7 | 196.55 | 35.407 | 2.03 | 24.03 | 0.23 | 0.02 | 0.19 | 0.69 |
2031 | 60.1 | 165.78 | 35.576 | 6.79 | 20.37 | 0.57 | < 0.02 | 0.17 | 2.14 |
2030 | 60.2 | < 0.02 | < 0.02 | < 0.02 | 20.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 101 | 166.18 | 35.532 | 8.20 | 18.51 | 0.68 | < 0.02 | 0.03 | 2.62 |
2028 | 101 | < 0.02 | < 0.02 | < 0.02 | 18.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 101.1 | < 0.02 | < 0.02 | < 0.02 | 18.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 200.9 | 174.98 | 35.325 | 10.43 | 15.95 | 0.81 | < 0.02 | 0.02 | 3.69 |
2025 | 300.9 | 183.56 | 35.185 | 12.09 | 14.31 | 0.92 | < 0.02 | 0.02 | 4.33 |
2024 | 301 | < 0.02 | < 0.02 | < 0.02 | 14.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 400.8 | 190.12 | 34.953 | 15.79 | 12.08 | 1.13 | < 0.02 | < 0.02 | 6.22 |
2021 | 400.8 | < 0.02 | < 0.02 | < 0.02 | 12.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 400.8 | < 0.02 | < 0.02 | < 0.02 | 12.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 501.3 | 202.58 | 34.706 | 19.67 | 9.69 | 1.37 | < 0.02 | < 0.02 | 8.39 |
2018 | 601.2 | < 0.02 | < 0.02 | < 0.02 | 8.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 601.2 | 206.96 | 34.571 | 22.64 | 8.28 | 1.56 | < 0.02 | < 0.02 | 11.58 |
2017 | 700.5 | 210.53 | 34.474 | 24.95 | 7.25 | 1.72 | < 0.02 | < 0.02 | 15.45 |
2015 | 700.5 | < 0.02 | < 0.02 | < 0.02 | 7.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 700.5 | < 0.02 | < 0.02 | < 0.02 | 7.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 800.6 | 206.47 | 34.430 | 27.23 | 6.35 | 1.89 | < 0.02 | < 0.02 | 22.01 |
2013 | 1000.9 | 189.54 | 34.443 | 30.60 | 5.21 | 2.14 | < 0.02 | < 0.02 | 40.20 |
2012 | 1000.9 | < 0.02 | < 0.02 | < 0.02 | 5.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 1200.9 | < 0.02 | < 0.02 | < 0.02 | 4.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 1201.1 | < 0.02 | < 0.02 | < 0.02 | 4.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 1201.1 | 174.04 | 34.492 | 33.06 | 4.20 | 2.34 | < 0.02 | < 0.02 | 62.51 |
2008 | 1400.1 | 158.55 | 34.553 | 35.09 | 3.36 | 2.50 | < 0.02 | < 0.02 | 85.57 |
2006 | 1600.7 | < 0.02 | < 0.02 | < 0.02 | 2.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 1600.8 | 155.38 | 34.609 | 35.66 | 2.76 | 2.55 | < 0.02 | < 0.02 | 98.49 |
12003 | 1800.5 | < 0.02 | < 0.02 | < 0.02 | 2.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 1800.6 | 163.15 | 34.644 | 35.06 | 2.47 | 2.50 | < 0.02 | < 0.02 | 99.20 |
12004 | 1800.6 | < 0.02 | < 0.02 | < 0.02 | 2.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12002 | 2000.3 | 168.55 | 34.666 | 34.59 | 2.33 | 2.46 | < 0.02 | < 0.02 | 98.51 |
12001 | 2194 | 178.51 | 34.692 | 33.79 | 2.13 | 2.38 | < 0.02 | < 0.02 | 97.79 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |