Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 12
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-05-02 06:26 to 2018-05-02 09:09 UTC
Where: 27° 17.7' S 154° 06.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 10.5 | 211.51 | 35.251 | 0.03 | 25.38 | 0.07 | < 0.02 | < 0.02 | 0.54 |
2036 | 11.3 | < 0.02 | < 0.02 | < 0.02 | 25.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 41.5 | < 0.02 | < 0.02 | < 0.02 | 24.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 41.8 | 213.35 | 35.254 | 0.04 | 24.80 | 0.05 | < 0.02 | < 0.02 | 0.60 |
32 | 81.2 | 170.65 | 35.540 | 5.25 | 21.77 | 0.46 | < 0.02 | 0.26 | 1.71 |
2031 | 125.5 | 165.47 | 35.525 | 8.35 | 18.48 | 0.68 | < 0.02 | 0.02 | 2.58 |
2030 | 125.6 | < 0.02 | < 0.02 | < 0.02 | 18.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 200 | 175.83 | 35.373 | 9.69 | 16.42 | 0.76 | < 0.02 | < 0.02 | 3.26 |
2027 | 275.1 | < 0.02 | < 0.02 | < 0.02 | 14.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 275.3 | 181.73 | 35.211 | 11.82 | 14.59 | 0.89 | < 0.02 | < 0.02 | 4.20 |
2026 | 350.7 | 188.96 | 35.066 | 13.82 | 13.04 | 1.01 | < 0.02 | < 0.02 | 5.04 |
2025 | 450.1 | 197.58 | 34.833 | 17.49 | 10.86 | 1.24 | < 0.02 | < 0.02 | 6.84 |
2024 | 450.2 | < 0.02 | < 0.02 | < 0.02 | 10.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 549.9 | 205.40 | 34.627 | 21.27 | 8.92 | 1.48 | < 0.02 | < 0.02 | 9.86 |
2021 | 651 | < 0.02 | < 0.02 | < 0.02 | 7.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 651.1 | 208.70 | 34.508 | 24.15 | 7.60 | 1.67 | < 0.02 | < 0.02 | 13.98 |
2020 | 750.8 | 208.57 | 34.449 | 26.21 | 6.72 | 1.82 | < 0.02 | < 0.02 | 18.75 |
2018 | 850.2 | < 0.02 | < 0.02 | < 0.02 | 5.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 850.2 | 201.42 | 34.427 | 28.41 | 5.94 | 1.97 | < 0.02 | < 0.02 | 26.97 |
2017 | 951.1 | 193.65 | 34.434 | 29.97 | 5.43 | 2.08 | < 0.02 | < 0.02 | 35.55 |
2015 | 1050.6 | < 0.02 | < 0.02 | < 0.02 | 4.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 1050.8 | 184.85 | 34.454 | 31.49 | 4.85 | 2.20 | < 0.02 | < 0.02 | 46.64 |
1214 | 1199.7 | 174.31 | 34.495 | 33.10 | 4.20 | 2.33 | < 0.02 | < 0.02 | 62.21 |
2012 | 1350.1 | < 0.02 | < 0.02 | < 0.02 | 3.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 1350.3 | 164.31 | 34.532 | 34.39 | 3.67 | 2.44 | < 0.02 | < 0.02 | 76.39 |
2011 | 1499.8 | 154.97 | 34.575 | 35.56 | 3.13 | 2.53 | < 0.02 | < 0.02 | 91.44 |
2010 | 1701.1 | 157.21 | 34.623 | 35.59 | 2.64 | 2.54 | < 0.02 | < 0.02 | 99.27 |
2009 | 1701.2 | < 0.02 | < 0.02 | < 0.02 | 2.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 1900.2 | 168.01 | 34.663 | 34.66 | 2.33 | 2.46 | < 0.02 | < 0.02 | 98.08 |
2006 | 2099.8 | < 0.02 | < 0.02 | < 0.02 | 2.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 2099.9 | 176.99 | 34.692 | 33.83 | 2.15 | 2.40 | < 0.02 | < 0.02 | 97.00 |
2005 | 2299.6 | 182.35 | 34.706 | 33.43 | 2.03 | 2.36 | < 0.02 | < 0.02 | 97.73 |
12004 | 2499.7 | 186.01 | 34.715 | 33.16 | 1.93 | 2.33 | < 0.02 | < 0.02 | 99.52 |
12003 | 2698.9 | < 0.02 | < 0.02 | < 0.02 | 1.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12002 | 2699.1 | 188.60 | 34.721 | 33.07 | 1.84 | 2.33 | < 0.02 | < 0.02 | 101.80 |
12001 | 2946 | 189.94 | 34.720 | 33.04 | 1.80 | 2.32 | < 0.02 | < 0.02 | 102.83 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |