Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-29 07:55 to 2018-04-29 11:26 UTC
Where: 27° 15.3' S 154° 19.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 16.3 | 210.04 | 35.363 | 0.04 | 25.58 | 0.06 | < 0.02 | < 0.02 | 0.50 |
2036 | 16.6 | < 0.02 | < 0.02 | < 0.02 | 25.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 49.8 | 209.77 | 35.366 | 0.05 | 25.59 | 0.05 | < 0.02 | < 0.02 | 0.53 |
2033 | 49.8 | < 0.02 | < 0.02 | < 0.02 | 25.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 151.2 | 178.51 | 35.742 | 4.04 | 21.54 | 0.38 | < 0.02 | 0.03 | 1.05 |
2031 | 250.2 | 169.00 | 35.437 | 9.27 | 17.45 | 0.74 | < 0.02 | < 0.02 | 3.00 |
2030 | 250.3 | < 0.02 | < 0.02 | < 0.02 | 17.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 351.3 | 182.04 | 35.231 | 11.53 | 14.82 | 0.86 | < 0.02 | < 0.02 | 4.03 |
2027 | 451.5 | < 0.02 | < 0.02 | < 0.02 | 11.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 451.6 | 198.12 | 34.853 | 17.26 | 11.07 | 1.21 | < 0.02 | < 0.02 | 6.73 |
2026 | 551.2 | 202.85 | 34.681 | 20.54 | 9.37 | 1.42 | < 0.02 | < 0.02 | 9.10 |
2024 | 650.6 | < 0.02 | < 0.02 | < 0.02 | 7.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 650.6 | 210.40 | 35.329 | 0.29 | 7.72 | 0.08 | < 0.02 | 0.02 | 1.24 |
2023 | 751.3 | 206.87 | 34.463 | 26.07 | 6.86 | 1.80 | < 0.02 | < 0.02 | 18.55 |
2021 | 901 | < 0.02 | < 0.02 | < 0.02 | 5.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 901 | 196.96 | 34.430 | 29.38 | 5.65 | 2.03 | < 0.02 | < 0.02 | 31.91 |
2020 | 1050.9 | 184.14 | 34.455 | 31.70 | 4.79 | 2.21 | < 0.02 | < 0.02 | 47.74 |
2019 | 1200.9 | 173.28 | 34.498 | 33.28 | 4.13 | 2.33 | < 0.02 | < 0.02 | 63.69 |
2018 | 1200.9 | < 0.02 | < 0.02 | < 0.02 | 4.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 1401.2 | 159.40 | 34.547 | 35.06 | 3.44 | 2.47 | < 0.02 | < 0.02 | 83.11 |
2016 | 1599.3 | 155.06 | 34.592 | 35.75 | 2.94 | 2.53 | < 0.02 | < 0.02 | 94.73 |
2015 | 1599.5 | < 0.02 | < 0.02 | < 0.02 | 2.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 1800.6 | 159.93 | 34.633 | 35.39 | 2.56 | 2.51 | < 0.02 | < 0.02 | 98.78 |
2012 | 2000.6 | < 0.02 | < 0.02 | < 0.02 | 2.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 2000.7 | 169.40 | 34.666 | 34.59 | 2.33 | 2.44 | < 0.02 | < 0.02 | 97.13 |
2011 | 2251.2 | 178.38 | 34.696 | 33.81 | 2.11 | 2.37 | < 0.02 | < 0.02 | 97.93 |
2009 | 2500.8 | < 0.02 | < 0.02 | < 0.02 | 1.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 2500.9 | 185.92 | 34.715 | 33.23 | 1.90 | 2.33 | < 0.02 | < 0.02 | 100.49 |
2008 | 2800.3 | 191.82 | 34.723 | 33.11 | 1.68 | 2.32 | < 0.02 | < 0.02 | 105.53 |
2006 | 3099.4 | < 0.02 | < 0.02 | < 0.02 | 1.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 3099.6 | 195.93 | 34.724 | 33.14 | 1.49 | 2.32 | < 0.02 | < 0.02 | 110.66 |
2005 | 3399.7 | 199.41 | 34.719 | 33.35 | 1.27 | 2.31 | < 0.02 | < 0.02 | 116.12 |
12003 | 3699.8 | < 0.02 | < 0.02 | < 0.02 | 1.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 3699.8 | 200.53 | 34.717 | 33.43 | 1.21 | 2.34 | < 0.02 | < 0.02 | 118.34 |
12002 | 4000.3 | 201.02 | 34.716 | 33.51 | 1.19 | 2.34 | < 0.02 | < 0.02 | 119.51 |
12001 | 4325.8 | 201.11 | 34.715 | 33.55 | 1.21 | 2.36 | < 0.02 | < 0.02 | 120.11 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |