Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-27 02:45 to 2018-04-27 04:44 UTC
Where: 27° 19.7' S 154° 00.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 11 | 209.15 | 35.204 | 0.03 | 26.11 | 0.04 | < 0.02 | < 0.02 | 0.50 |
2036 | 11.1 | < 0.02 | < 0.02 | < 0.02 | 26.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 51 | 208.97 | 35.262 | 0.04 | 26.02 | 0.04 | < 0.02 | < 0.02 | 0.49 |
32 | 75.1 | 181.37 | 35.434 | 3.38 | 23.58 | 0.31 | < 0.02 | 0.44 | 1.52 |
2033 | 75.1 | < 0.02 | < 0.02 | < 0.02 | 23.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 125.6 | 165.07 | 35.629 | 7.14 | 19.66 | 0.60 | < 0.02 | < 0.02 | 1.97 |
2029 | 165.8 | 172.93 | 35.552 | 7.53 | 18.43 | 0.62 | < 0.02 | 0.03 | 2.34 |
2030 | 165.9 | < 0.02 | < 0.02 | < 0.02 | 18.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 200.4 | < 0.02 | < 0.02 | < 0.02 | 17.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 200.5 | 167.66 | 35.450 | 9.18 | 17.50 | 0.73 | < 0.02 | < 0.02 | 2.96 |
2026 | 249.7 | 176.59 | 35.359 | 10.05 | 16.11 | 0.78 | < 0.02 | < 0.02 | 3.43 |
2025 | 300.5 | 180.21 | 35.223 | 11.69 | 14.77 | 0.88 | < 0.02 | < 0.02 | 4.18 |
2022 | 400.7 | 188.29 | 34.991 | 15.24 | 12.39 | 1.10 | < 0.02 | < 0.02 | 5.90 |
2024 | 400.8 | < 0.02 | < 0.02 | < 0.02 | 12.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 400.8 | < 0.02 | < 0.02 | < 0.02 | 12.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 500.9 | 201.15 | 34.740 | 19.12 | 9.99 | 1.33 | < 0.02 | < 0.02 | 7.88 |
2021 | 501 | < 0.02 | < 0.02 | < 0.02 | 10.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 501.2 | < 0.02 | < 0.02 | < 0.02 | 10.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2018 | 551.2 | < 0.02 | < 0.02 | < 0.02 | 9.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 551.4 | 204.99 | 34.643 | 20.96 | 9.03 | 1.45 | < 0.02 | < 0.02 | 9.51 |
2016 | 600.5 | 206.38 | 34.587 | 22.37 | 8.46 | 1.54 | < 0.02 | < 0.02 | 11.11 |
1214 | 700.3 | 210.26 | 34.481 | 25.01 | 7.19 | 1.72 | < 0.02 | < 0.02 | 15.46 |
2015 | 700.3 | < 0.02 | < 0.02 | < 0.02 | 7.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2012 | 801 | < 0.02 | < 0.02 | < 0.02 | 6.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 801.1 | 206.51 | 34.434 | 27.15 | 6.40 | 1.87 | < 0.02 | < 0.02 | 22.02 |
2010 | 1049.9 | 182.80 | 34.463 | 31.82 | 4.73 | 2.20 | < 0.02 | < 0.02 | 49.42 |
2008 | 1049.9 | < 0.02 | < 0.02 | < 0.02 | 4.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 1050 | < 0.02 | < 0.02 | < 0.02 | 4.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 1050.1 | < 0.02 | < 0.02 | < 0.02 | 4.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2006 | 1300.5 | < 0.02 | < 0.02 | < 0.02 | 3.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 1300.5 | 164.00 | 34.525 | 34.49 | 3.72 | 2.42 | < 0.02 | < 0.02 | 75.40 |
2005 | 1500.7 | < 0.02 | < 0.02 | < 0.02 | 2.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 1500.7 | 153.46 | 34.596 | 35.84 | 2.90 | 2.53 | < 0.02 | < 0.02 | 97.02 |
12003 | 1600.4 | < 0.02 | < 0.02 | < 0.02 | 2.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12002 | 1600.4 | 155.24 | 34.613 | 35.79 | 2.73 | 2.53 | < 0.02 | < 0.02 | 99.01 |
12001 | 1743.6 | 160.33 | 34.623 | 35.37 | 2.51 | 2.49 | < 0.02 | < 0.02 | 99.96 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |