Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 8
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-26 21:44 to 2018-04-27 00:39 UTC
Where: 27° 18.5' S 154° 08.7' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2036 | 10.7 | < 0.02 | < 0.02 | < 0.02 | 26.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 10.8 | 208.61 | 35.196 | 0.03 | 26.16 | 0.06 | < 0.02 | < 0.02 | 0.58 |
2034 | 60.7 | 205.17 | 35.248 | 0.27 | 26.11 | 0.08 | < 0.02 | 0.04 | 0.68 |
32 | 121.4 | 168.60 | 35.723 | 5.07 | 21.60 | 0.46 | < 0.02 | 0.04 | 1.38 |
2033 | 121.4 | < 0.02 | < 0.02 | < 0.02 | 21.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 198.8 | 166.27 | 35.570 | 7.77 | 18.84 | 0.65 | < 0.02 | 0.02 | 2.38 |
2030 | 198.8 | < 0.02 | < 0.02 | < 0.02 | 18.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 300.9 | 178.42 | 35.300 | 10.66 | 15.63 | 0.81 | < 0.02 | < 0.02 | 3.82 |
2027 | 399.2 | < 0.02 | < 0.02 | < 0.02 | 12.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 399.4 | 188.02 | 35.035 | 14.34 | 12.85 | 1.05 | < 0.02 | < 0.02 | 5.56 |
2026 | 502.1 | 202.49 | 34.726 | 19.24 | 9.90 | 1.35 | < 0.02 | < 0.02 | 8.13 |
2024 | 603.6 | < 0.02 | < 0.02 | < 0.02 | 8.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 603.9 | 208.39 | 34.551 | 22.89 | 8.12 | 1.59 | < 0.02 | < 0.02 | 11.99 |
2023 | 702.6 | 209.73 | 34.481 | 24.85 | 7.26 | 1.72 | < 0.02 | < 0.02 | 15.50 |
2021 | 802 | < 0.02 | < 0.02 | < 0.02 | 6.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 802.3 | 206.69 | 34.427 | 27.41 | 6.26 | 1.90 | < 0.02 | < 0.02 | 22.77 |
2020 | 903.7 | 195.48 | 34.435 | 29.47 | 5.60 | 2.05 | < 0.02 | < 0.02 | 33.30 |
2018 | 1001.7 | < 0.02 | < 0.02 | < 0.02 | 4.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 1002 | 187.44 | 34.446 | 31.11 | 4.99 | 2.17 | < 0.02 | < 0.02 | 43.79 |
2017 | 1153.4 | 174.27 | 34.490 | 33.15 | 4.19 | 2.32 | < 0.02 | < 0.02 | 62.17 |
2015 | 1300.3 | < 0.02 | < 0.02 | < 0.02 | 3.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 1300.4 | 161.94 | 34.533 | 34.72 | 3.58 | 2.45 | < 0.02 | < 0.02 | 79.00 |
1214 | 1450.3 | 155.42 | 34.569 | 35.58 | 3.16 | 2.52 | < 0.02 | < 0.02 | 91.21 |
2012 | 1601.9 | < 0.02 | < 0.02 | < 0.02 | 2.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 1602.2 | 154.57 | 34.603 | 35.83 | 2.81 | 2.54 | < 0.02 | < 0.02 | 98.86 |
2011 | 1750.4 | 160.47 | 34.636 | 35.36 | 2.53 | 2.50 | < 0.02 | < 0.02 | 99.80 |
2009 | 1902.5 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 1902.8 | 167.26 | 34.660 | 34.76 | 2.35 | 2.46 | < 0.02 | < 0.02 | 98.74 |
2008 | 2100.9 | 177.17 | 34.688 | 33.88 | 2.16 | 2.39 | < 0.02 | < 0.02 | 96.75 |
2006 | 2301.4 | < 0.02 | < 0.02 | < 0.02 | 2.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 2301.5 | 182.71 | 34.704 | 33.41 | 2.04 | 2.35 | < 0.02 | < 0.02 | 97.48 |
2005 | 2502.2 | 185.70 | 34.712 | 33.20 | 1.97 | 2.34 | < 0.02 | < 0.02 | 98.58 |
12004 | 2703.1 | 190.08 | 34.719 | 33.02 | 1.81 | 2.32 | < 0.02 | < 0.02 | 102.39 |
12003 | 2703.1 | < 0.02 | < 0.02 | < 0.02 | 1.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12002 | 2901.8 | 192.27 | 34.723 | 32.96 | 1.71 | 2.32 | < 0.02 | < 0.02 | 104.95 |
12001 | 3028.8 | 193.25 | 34.724 | 33.00 | 1.67 | 2.31 | < 0.02 | < 0.02 | 106.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |