Data Trawler - Deployment Details

Deployment Details

Survey: - IN2018_V03 [details]

Deployment Type: - CTD Cast / Hydrology

Cast: 7

Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 23 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR

When: 2018-04-25 08:47 to 2018-04-25 13:03 UTC

Where: 27° 11.3' S    154° 37.5' E

Maximum Depth (m): unknown

View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.

Bottle Data

Bottle
Number
Pressure Oxygen
(µM)
Salinity
(psu)
Nitrate
(µM)
Temperature
(deg C)
Orthophosphate
(µM)
Ammonia
(µM)
Nitrite
(µM)
Silicate
(µM)
12004 4149.9 201.29 34.722 33.52 1.18 2.34 < 0.02 < 0.02 119.96
12003 4149.7 < 0.02 < 0.02 < 0.02 1.18 < 0.02 < 0.02 < 0.02 < 0.02
12002 4500.2 201.15 34.726 33.57 1.21 2.35 < 0.02 < 0.02 120.32
12001 4839.8 201.47 34.719 33.59 1.24 2.36 < 0.02 < 0.02 120.59
2036 10.5 < 0.02 < 0.02 < 0.02 25.95 < 0.02 < 0.02 < 0.02 < 0.02
2035 10.3 209.01 35.153 0.03 25.95 0.04 < 0.02 < 0.02 0.64
2034 50.9 208.97 35.426 0.03 25.80 0.07 < 0.02 < 0.02 0.68
2033 51.1 < 0.02 < 0.02 < 0.02 25.81 < 0.02 < 0.02 < 0.02 < 0.02
2031 200.2 171.86 35.664 6.14 19.91 0.53 < 0.02 0.02 1.70
2030 200.3 < 0.02 < 0.02 < 0.02 19.91 < 0.02 < 0.02 < 0.02 < 0.02
2029 300.5 184.58 35.538 7.39 17.49 0.59 < 0.02 0.02 2.28
2028 401.4 186.46 35.214 11.54 14.46 0.87 < 0.02 0.02 4.05
2027 401.3 < 0.02 < 0.02 < 0.02 14.46 < 0.02 < 0.02 < 0.02 < 0.02
2026 500.4 192.18 34.907 17.08 11.41 1.20 < 0.02 0.02 6.99
2025 600.2 205.98 34.641 20.97 9.02 1.45 < 0.02 0.02 9.36
2024 600.3 < 0.02 < 0.02 < 0.02 9.02 < 0.02 < 0.02 < 0.02 < 0.02
2023 750.3 210.89 34.451 25.62 6.91 1.76 < 0.02 < 0.02 16.80
2022 950.6 193.11 34.448 29.87 5.52 2.06 < 0.02 < 0.02 34.65
2021 950.4 < 0.02 < 0.02 < 0.02 5.52 < 0.02 < 0.02 < 0.02 < 0.02
2020 1150.8 178.20 34.479 32.57 4.44 2.28 < 0.02 < 0.02 55.75
2019 1350.7 163.68 34.536 34.48 3.70 2.43 < 0.02 < 0.02 75.58
2018 1350.6 < 0.02 < 0.02 < 0.02 3.70 < 0.02 < 0.02 < 0.02 < 0.02
2017 1549.8 154.84 34.575 35.60 3.19 2.52 < 0.02 < 0.02 90.56
2016 1749.6 154.35 34.616 35.84 2.78 2.54 < 0.02 < 0.02 98.83
2015 1749.7 < 0.02 < 0.02 < 0.02 2.78 < 0.02 < 0.02 < 0.02 < 0.02
2013 2299.8 179.76 34.698 33.65 2.11 2.36 < 0.02 < 0.02 96.53
2012 2299.7 < 0.02 < 0.02 < 0.02 2.11 < 0.02 < 0.02 < 0.02 < 0.02
2011 2600 188.20 34.725 33.10 1.85 2.31 < 0.02 < 0.02 100.92
2010 2898.7 193.78 34.735 33.10 1.57 2.31 < 0.02 < 0.02 107.79
2009 2898.6 < 0.02 < 0.02 < 0.02 1.57 < 0.02 < 0.02 < 0.02 < 0.02
2008 3201.1 197.85 34.728 33.24 1.36 2.32 < 0.02 < 0.02 113.24
2006 3500.5 < 0.02 < 0.02 < 0.02 1.24 < 0.02 < 0.02 < 0.02 < 0.02
2005 3800.2 200.97 34.722 33.47 1.19 2.34 < 0.02 < 0.02 118.79
1214 1998.9 164.75 34.656 34.96 2.43 2.47 < 0.02 < 0.02 97.81
1201 3500.6 199.95 34.727 33.42 1.24 2.33 < 0.02 < 0.02 116.95
32 124.8 175.16 35.733 3.76 22.40 0.37 < 0.02 0.03 1.11
Gear / Instruments used.
InstrumentManufacturerModelSerial NoMeasuring
Autosal SalinometerGuildline Instruments8400BSN 71611Salinity (psu)
CTD 23 - SN 1312SeabirdSBE9111312
CTD 24 - SN 1332SeabirdSBE9+ V_21332
Chelsea Tech FluorometerChelsea TechFluorometer65941001Fluorescence (arbitrary units)
Conductivity CTD 24 - SN 4664SeabirdSBE4C4664
Licor - CTD 24 - SN 70111QCP230070111PAR (uE/m**2/sec)
Oxygen CTD 24 - SN 3534SeabirdSBE433534Oxygen (µM)
Pressure CTD 24Digiquartz410K-1341332Pressure (decibars)
Quikchem 8000 series auto analyzerLachat Instruments8000 SeriesOrthophosphate (µM)
Quikchem 8000 series auto analyzerLachat Instruments8000 SeriesAmmonia (µM)
Quikchem 8000 series auto analyzerLachat Instruments8000 SeriesNitrite (µM)
Quikchem 8000 series auto analyzerLachat Instruments8000 SeriesNitrate (µM)
Quikchem 8000 series auto analyzerLachat Instruments8000 SeriesSilicate (µM)
SCRIPPS Automated Photometric Oxygen SystemSCRIPPSOxygen (µM)
Temperature CTD 23 - SN 6189SeabirdSBE3T6189Temperature (deg C)
Temperature CTD 24 - SN 4522Sea-Bird Electronics IncSBE3T4522Temperature (deg C)
Transmissometer - CTD 24 -CST-1421DRWET LabsC-StarCST-1421DRTransmittance (%)