Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-22 08:37 to 2018-04-22 12:47 UTC
Where: 27° 04.9' S 155° 16.9' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 10.4 | 215.58 | 35.598 | 0.04 | 24.33 | 0.03 | < 0.02 | < 0.02 | 0.41 |
2036 | 10.5 | < 0.02 | < 0.02 | < 0.02 | 24.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 50.5 | 216.29 | 35.728 | 0.03 | 24.33 | 0.04 | < 0.02 | < 0.02 | 0.40 |
2033 | 150.2 | < 0.02 | < 0.02 | < 0.02 | 19.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 150.2 | 202.94 | 35.748 | 3.25 | 19.43 | 0.32 | < 0.02 | 0.03 | 0.96 |
2031 | 249 | 209.06 | 35.699 | 3.96 | 18.22 | 0.36 | < 0.02 | < 0.02 | 1.14 |
2029 | 349.9 | 191.15 | 35.339 | 9.49 | 15.38 | 0.72 | < 0.02 | < 0.02 | 3.03 |
2030 | 349.9 | < 0.02 | < 0.02 | < 0.02 | 15.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 449.5 | 195.35 | 35.076 | 13.73 | 12.77 | 0.99 | < 0.02 | < 0.02 | 4.78 |
2026 | 549.3 | 199.59 | 34.806 | 17.98 | 10.50 | 1.26 | < 0.02 | < 0.02 | 7.03 |
2027 | 549.3 | < 0.02 | < 0.02 | < 0.02 | 10.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 650.3 | 207.99 | 34.596 | 21.75 | 8.58 | 1.52 | < 0.02 | < 0.02 | 10.22 |
2023 | 749.3 | 209.95 | 34.498 | 24.59 | 7.34 | 1.71 | < 0.02 | < 0.02 | 15.03 |
2024 | 749.3 | < 0.02 | < 0.02 | < 0.02 | 7.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 900.3 | 202.76 | 34.452 | 28.02 | 6.03 | 1.95 | < 0.02 | < 0.02 | 25.86 |
2020 | 1099.6 | 182.26 | 34.473 | 31.85 | 4.68 | 2.23 | < 0.02 | < 0.02 | 50.19 |
2021 | 1099.6 | < 0.02 | < 0.02 | < 0.02 | 4.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 1298.8 | 167.70 | 34.522 | 33.86 | 3.90 | 2.39 | < 0.02 | < 0.02 | 70.08 |
2018 | 1501 | < 0.02 | < 0.02 | < 0.02 | 3.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 1501 | 156.18 | 34.562 | 35.28 | 3.34 | 2.51 | < 0.02 | < 0.02 | 87.06 |
2016 | 1749.2 | 151.80 | 34.607 | 35.92 | 2.81 | 2.56 | < 0.02 | < 0.02 | 100.68 |
1214 | 1999.2 | 161.05 | 34.647 | 35.25 | 2.43 | 2.51 | < 0.02 | < 0.02 | 102.35 |
2015 | 1999.2 | < 0.02 | < 0.02 | < 0.02 | 2.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 2299.8 | 175.83 | 34.688 | 33.93 | 2.14 | 2.40 | < 0.02 | < 0.02 | 98.84 |
2011 | 2598.7 | 187.40 | 34.717 | 33.06 | 1.88 | 2.33 | < 0.02 | < 0.02 | 100.71 |
2012 | 2598.8 | < 0.02 | < 0.02 | < 0.02 | 1.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 2900 | 193.11 | 34.725 | 32.94 | 1.63 | 2.32 | < 0.02 | < 0.02 | 106.39 |
2008 | 3198.8 | 197.18 | 34.722 | 33.05 | 1.40 | 2.33 | < 0.02 | < 0.02 | 112.64 |
2009 | 3198.8 | < 0.02 | < 0.02 | < 0.02 | 1.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 3499.1 | 199.99 | 34.720 | 33.23 | 1.24 | 2.34 | < 0.02 | < 0.02 | 117.15 |
2005 | 3798.8 | 200.71 | 34.717 | 33.39 | 1.19 | 2.34 | < 0.02 | < 0.02 | 119.14 |
2006 | 3798.8 | < 0.02 | < 0.02 | < 0.02 | 1.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 4149.1 | 201.20 | 34.715 | 33.44 | 1.19 | 2.35 | < 0.02 | < 0.02 | 120.47 |
12003 | 4499.6 | < 0.02 | < 0.02 | < 0.02 | 1.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12002 | 4499.6 | 200.97 | 34.714 | 33.47 | 1.21 | 2.36 | < 0.02 | < 0.02 | 120.71 |
12001 | 4848.2 | 201.29 | 34.714 | 33.49 | 1.23 | 2.36 | < 0.02 | < 0.02 | 121.14 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |