Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-21 01:00 to 2018-04-21 05:20 UTC
Where: 27° 09.4' S 154° 56.5' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 11 | 215.18 | 35.628 | 0.02 | 24.63 | 0.06 | < 0.02 | < 0.02 | 0.31 |
2036 | 11.1 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 59.9 | < 0.02 | < 0.02 | < 0.02 | 24.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 60.1 | 216.52 | 35.679 | 0.03 | 24.12 | 0.06 | < 0.02 | < 0.02 | 0.30 |
32 | 121.1 | 192.27 | 35.732 | 2.84 | 21.17 | 0.32 | < 0.02 | 0.04 | 0.57 |
2031 | 250.7 | 201.33 | 35.676 | 4.61 | 18.56 | 0.42 | < 0.02 | < 0.02 | 1.04 |
2030 | 250.7 | < 0.02 | < 0.02 | < 0.02 | 18.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 350.9 | 190.39 | 35.343 | 9.56 | 15.60 | 0.74 | < 0.02 | < 0.02 | 2.80 |
2027 | 450.1 | < 0.02 | < 0.02 | < 0.02 | 12.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 450.2 | 197.13 | 35.088 | 13.40 | 12.93 | 0.97 | < 0.02 | < 0.02 | 4.44 |
2026 | 551.1 | 202.05 | 34.815 | 17.94 | 10.51 | 1.25 | < 0.02 | < 0.02 | 6.67 |
2025 | 649.5 | 207.94 | 34.614 | 21.57 | 8.74 | 1.50 | < 0.02 | < 0.02 | 9.64 |
2024 | 749.4 | < 0.02 | < 0.02 | < 0.02 | 7.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 750 | 210.49 | 34.494 | 24.61 | 7.40 | 1.69 | < 0.02 | < 0.02 | 14.38 |
2021 | 951 | < 0.02 | < 0.02 | < 0.02 | 5.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 951.2 | 198.79 | 34.432 | 29.15 | 5.72 | 2.01 | < 0.02 | < 0.02 | 30.22 |
2020 | 1150.7 | 178.55 | 34.473 | 32.51 | 4.46 | 2.28 | < 0.02 | < 0.02 | 55.22 |
2018 | 1349.9 | < 0.02 | < 0.02 | < 0.02 | 3.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 1350 | 164.40 | 34.524 | 34.29 | 3.74 | 2.42 | < 0.02 | < 0.02 | 74.75 |
2017 | 1550.5 | 155.46 | 34.566 | 35.29 | 3.24 | 2.51 | < 0.02 | < 0.02 | 89.20 |
2016 | 1749.2 | 151.89 | 34.604 | 35.76 | 2.83 | 2.56 | < 0.02 | < 0.02 | 99.97 |
2015 | 1854.5 | < 0.02 | < 0.02 | < 0.02 | 2.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 1999.1 | 160.78 | 34.646 | 35.69 | 2.44 | 2.56 | < 0.02 | < 0.02 | 100.09 |
2013 | 2300.8 | 175.61 | 34.692 | 33.68 | 2.17 | 2.39 | < 0.02 | < 0.02 | 98.02 |
2012 | 2300.9 | < 0.02 | < 0.02 | < 0.02 | 2.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 2601 | 185.97 | 34.714 | 32.87 | 1.92 | 2.33 | < 0.02 | < 0.02 | 99.86 |
2010 | 2899.3 | 192.76 | 34.724 | 32.66 | 1.65 | 2.31 | < 0.02 | < 0.02 | 106.05 |
2008 | 3198.3 | 197.58 | 34.722 | 32.74 | 1.39 | 2.31 | < 0.02 | < 0.02 | 112.69 |
2009 | 3198.3 | < 0.02 | < 0.02 | < 0.02 | 1.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 3499.1 | 200.08 | 34.723 | 32.92 | 1.23 | 2.33 | < 0.02 | < 0.02 | 117.14 |
2005 | 3799.5 | 201.02 | 34.716 | 32.95 | 1.19 | 2.34 | < 0.02 | < 0.02 | 118.80 |
2006 | 3799.5 | < 0.02 | < 0.02 | < 0.02 | 1.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 4100.7 | 201.06 | 34.722 | 33.00 | 1.18 | 2.34 | < 0.02 | < 0.02 | 119.80 |
12002 | 4398.5 | 201.24 | 34.715 | 33.03 | 1.20 | 2.34 | < 0.02 | < 0.02 | 120.53 |
12003 | 4398.6 | < 0.02 | < 0.02 | < 0.02 | 1.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12001 | 4846.5 | 201.38 | 34.715 | 33.04 | 1.23 | 2.35 | < 0.02 | < 0.02 | 120.67 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |