Deployment Details

Survey: - IN2018_V03 [details]

Deployment Type: - CTD Cast / Hydrology

Cast: 4

Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR

When: 2018-04-20 18:02 to 2018-04-20 21:24 UTC

Where: 27° 14.5' S    154° 18.3' E

Maximum Depth (m): unknown

View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.

Bottle Data

Bottle
Number
Pressure Oxygen
(µM)
Salinity
(psu)
Nitrate
(µM)
Temperature
(deg C)
Orthophosphate
(µM)
Ammonia
(µM)
Nitrite
(µM)
Silicate
(µM)
2035 10.1 209.73 35.337 0.02 25.83 0.06 < 0.02 < 0.02 0.50
2036 10.2 < 0.02 < 0.02 < 0.02 25.83 < 0.02 < 0.02 < 0.02 < 0.02
2033 40.9 < 0.02 < 0.02 < 0.02 25.84 < 0.02 < 0.02 < 0.02 < 0.02
2034 41 209.86 35.336 0.02 25.83 0.05 < 0.02 < 0.02 0.50
32 81 210.58 35.571 0.02 25.61 0.02 < 0.02 < 0.02 0.47
2030 120.1 < 0.02 < 0.02 < 0.02 22.96 < 0.02 < 0.02 < 0.02 < 0.02
2031 120.5 207.58 35.763 0.34 22.95 0.13 0.02 0.08 0.49
2029 202 187.49 35.733 4.09 20.22 0.36 < 0.02 < 0.02 0.85
2027 300 < 0.02 < 0.02 < 0.02 17.21 < 0.02 < 0.02 < 0.02 < 0.02
2028 300.2 174.80 35.449 8.73 17.23 0.69 < 0.02 < 0.02 2.65
2026 398.5 183.87 35.187 12.25 14.25 0.90 < 0.02 < 0.02 4.21
2024 500.5 < 0.02 < 0.02 < 0.02 11.25 < 0.02 < 0.02 < 0.02 < 0.02
2025 500.7 197.04 34.881 16.66 11.35 1.17 < 0.02 < 0.02 6.16
2023 600.4 201.87 34.677 20.79 9.36 1.44 < 0.02 < 0.02 9.40
2021 700.1 < 0.02 < 0.02 < 0.02 7.63 < 0.02 < 0.02 < 0.02 < 0.02
2022 700.2 210.49 34.510 24.03 7.66 1.65 < 0.02 < 0.02 13.18
2020 899.1 202.72 34.423 28.55 5.94 1.97 < 0.02 < 0.02 26.75
2018 1101.4 < 0.02 < 0.02 < 0.02 4.63 < 0.02 < 0.02 < 0.02 < 0.02
2019 1101.5 181.86 34.463 32.20 4.63 2.25 < 0.02 < 0.02 51.30
2017 1300.7 167.52 34.514 34.21 3.84 2.41 < 0.02 < 0.02 71.47
2015 1501.3 < 0.02 < 0.02 < 0.02 3.19 < 0.02 < 0.02 < 0.02 < 0.02
2016 1501.3 157.39 34.570 35.47 3.19 2.51 < 0.02 < 0.02 89.47
1214 1749.7 154.48 34.615 35.92 2.70 2.55 < 0.02 < 0.02 101.32
2012 2000.5 < 0.02 < 0.02 < 0.02 2.37 < 0.02 < 0.02 < 0.02 < 0.02
2013 2000.6 166.85 34.657 34.85 2.37 2.46 < 0.02 < 0.02 99.01
2011 2250.6 177.17 34.687 33.87 2.18 2.38 < 0.02 < 0.02 96.41
2009 2498.4 < 0.02 < 0.02 < 0.02 2.00 < 0.02 < 0.02 < 0.02 < 0.02
2010 2498.5 184.99 34.711 33.16 2.00 2.33 < 0.02 < 0.02 97.92
2008 2800.4 190.61 34.722 32.86 1.79 2.31 < 0.02 < 0.02 102.65
2006 3098.4 < 0.02 < 0.02 < 0.02 1.53 < 0.02 < 0.02 < 0.02 < 0.02
1201 3098.6 196.11 34.723 32.91 1.53 2.32 < 0.02 < 0.02 109.37
2005 3400.1 199.95 34.719 33.15 1.26 2.34 < 0.02 < 0.02 115.99
12003 3698.3 < 0.02 < 0.02 < 0.02 1.19 < 0.02 < 0.02 < 0.02 < 0.02
12004 3698.3 201.51 34.716 33.24 1.19 2.35 < 0.02 < 0.02 118.87
12002 3994.2 201.87 34.715 33.28 1.19 2.35 < 0.02 < 0.02 119.53
12001 4355.9 201.69 34.715 33.33 1.20 2.35 < 0.02 < 0.02 120.34
Gear / Instruments used.
InstrumentManufacturerModelSerial NoMeasuring
Autosal SalinometerGuildline Instruments8400BSN 71611Salinity (psu)
CTD 23 - SN 1312SeabirdSBE9111312
CTD 24 - SN 1332SeabirdSBE9+ V_21332
Chelsea Tech FluorometerChelsea TechFluorometer65941001Fluorescence (arbitrary units)
Conductivity CTD 24 - SN 4664SeabirdSBE4C4664
Licor - CTD 24 - SN 70111QCP230070111PAR (uE/m**2/sec)
Oxygen CTD 24 - SN 3534SeabirdSBE433534Oxygen (µM)
Pressure CTD 24Digiquartz410K-1341332Pressure (decibars)
Quikchem 8000 series auto analyzerLachat Instruments8000 SeriesOrthophosphate (µM)
Quikchem 8000 series auto analyzerLachat Instruments8000 SeriesAmmonia (µM)
Quikchem 8000 series auto analyzerLachat Instruments8000 SeriesNitrite (µM)
Quikchem 8000 series auto analyzerLachat Instruments8000 SeriesNitrate (µM)
Quikchem 8000 series auto analyzerLachat Instruments8000 SeriesSilicate (µM)
SCRIPPS Automated Photometric Oxygen SystemSCRIPPSOxygen (µM)
Temperature CTD 21 - SN 6189SeabirdSBE3T6189Temperature (deg C)
Temperature CTD 24 - SN 4522Sea-Bird Electronics IncSBE3T4522Temperature (deg C)
Transmissometer - CTD 24 -CST-1421DRWET LabsC-StarCST-1421DRTransmittance (%)