Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 4
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-20 18:02 to 2018-04-20 21:24 UTC
Where: 27° 14.5' S 154° 18.3' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 10.1 | 209.73 | 35.337 | 0.02 | 25.83 | 0.06 | < 0.02 | < 0.02 | 0.50 |
2036 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 25.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 40.9 | < 0.02 | < 0.02 | < 0.02 | 25.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 41 | 209.86 | 35.336 | 0.02 | 25.83 | 0.05 | < 0.02 | < 0.02 | 0.50 |
32 | 81 | 210.58 | 35.571 | 0.02 | 25.61 | 0.02 | < 0.02 | < 0.02 | 0.47 |
2030 | 120.1 | < 0.02 | < 0.02 | < 0.02 | 22.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 120.5 | 207.58 | 35.763 | 0.34 | 22.95 | 0.13 | 0.02 | 0.08 | 0.49 |
2029 | 202 | 187.49 | 35.733 | 4.09 | 20.22 | 0.36 | < 0.02 | < 0.02 | 0.85 |
2027 | 300 | < 0.02 | < 0.02 | < 0.02 | 17.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 300.2 | 174.80 | 35.449 | 8.73 | 17.23 | 0.69 | < 0.02 | < 0.02 | 2.65 |
2026 | 398.5 | 183.87 | 35.187 | 12.25 | 14.25 | 0.90 | < 0.02 | < 0.02 | 4.21 |
2024 | 500.5 | < 0.02 | < 0.02 | < 0.02 | 11.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 500.7 | 197.04 | 34.881 | 16.66 | 11.35 | 1.17 | < 0.02 | < 0.02 | 6.16 |
2023 | 600.4 | 201.87 | 34.677 | 20.79 | 9.36 | 1.44 | < 0.02 | < 0.02 | 9.40 |
2021 | 700.1 | < 0.02 | < 0.02 | < 0.02 | 7.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 700.2 | 210.49 | 34.510 | 24.03 | 7.66 | 1.65 | < 0.02 | < 0.02 | 13.18 |
2020 | 899.1 | 202.72 | 34.423 | 28.55 | 5.94 | 1.97 | < 0.02 | < 0.02 | 26.75 |
2018 | 1101.4 | < 0.02 | < 0.02 | < 0.02 | 4.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 1101.5 | 181.86 | 34.463 | 32.20 | 4.63 | 2.25 | < 0.02 | < 0.02 | 51.30 |
2017 | 1300.7 | 167.52 | 34.514 | 34.21 | 3.84 | 2.41 | < 0.02 | < 0.02 | 71.47 |
2015 | 1501.3 | < 0.02 | < 0.02 | < 0.02 | 3.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 1501.3 | 157.39 | 34.570 | 35.47 | 3.19 | 2.51 | < 0.02 | < 0.02 | 89.47 |
1214 | 1749.7 | 154.48 | 34.615 | 35.92 | 2.70 | 2.55 | < 0.02 | < 0.02 | 101.32 |
2012 | 2000.5 | < 0.02 | < 0.02 | < 0.02 | 2.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 2000.6 | 166.85 | 34.657 | 34.85 | 2.37 | 2.46 | < 0.02 | < 0.02 | 99.01 |
2011 | 2250.6 | 177.17 | 34.687 | 33.87 | 2.18 | 2.38 | < 0.02 | < 0.02 | 96.41 |
2009 | 2498.4 | < 0.02 | < 0.02 | < 0.02 | 2.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 2498.5 | 184.99 | 34.711 | 33.16 | 2.00 | 2.33 | < 0.02 | < 0.02 | 97.92 |
2008 | 2800.4 | 190.61 | 34.722 | 32.86 | 1.79 | 2.31 | < 0.02 | < 0.02 | 102.65 |
2006 | 3098.4 | < 0.02 | < 0.02 | < 0.02 | 1.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 3098.6 | 196.11 | 34.723 | 32.91 | 1.53 | 2.32 | < 0.02 | < 0.02 | 109.37 |
2005 | 3400.1 | 199.95 | 34.719 | 33.15 | 1.26 | 2.34 | < 0.02 | < 0.02 | 115.99 |
12003 | 3698.3 | < 0.02 | < 0.02 | < 0.02 | 1.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 3698.3 | 201.51 | 34.716 | 33.24 | 1.19 | 2.35 | < 0.02 | < 0.02 | 118.87 |
12002 | 3994.2 | 201.87 | 34.715 | 33.28 | 1.19 | 2.35 | < 0.02 | < 0.02 | 119.53 |
12001 | 4355.9 | 201.69 | 34.715 | 33.33 | 1.20 | 2.35 | < 0.02 | < 0.02 | 120.34 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |