Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 3
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-20 10:59 to 2018-04-20 15:11 UTC
Where: 27° 12.6' S 154° 37.8' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2035 | 9.1 | 211.87 | 35.531 | 0.03 | 25.26 | 0.04 | < 0.02 | < 0.02 | 0.41 |
2036 | 9.1 | < 0.02 | < 0.02 | < 0.02 | 25.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 40.2 | 211.43 | 35.567 | 0.03 | 25.22 | 0.04 | < 0.02 | < 0.02 | 0.41 |
32 | 138.1 | 181.41 | 35.740 | 3.17 | 22.39 | 0.32 | < 0.02 | 0.03 | 0.74 |
2033 | 138.2 | < 0.02 | < 0.02 | < 0.02 | 22.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 249.3 | 175.43 | 35.603 | 6.70 | 18.79 | 0.55 | < 0.02 | < 0.02 | 1.72 |
2030 | 352.2 | < 0.02 | < 0.02 | < 0.02 | 16.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 352.2 | 191.02 | 35.444 | 7.84 | 16.51 | 0.61 | < 0.02 | < 0.02 | 2.16 |
2028 | 450.5 | 194.99 | 35.148 | 12.36 | 13.58 | 0.88 | < 0.02 | < 0.02 | 3.93 |
2026 | 599.8 | 203.43 | 34.713 | 19.58 | 9.81 | 1.35 | < 0.02 | < 0.02 | 7.86 |
2027 | 599.8 | < 0.02 | < 0.02 | < 0.02 | 9.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 700.6 | 207.32 | 34.563 | 22.85 | 8.16 | 1.57 | < 0.02 | < 0.02 | 11.67 |
2023 | 800.4 | 211.20 | 34.458 | 25.46 | 6.99 | 1.75 | < 0.02 | < 0.02 | 16.20 |
2024 | 800.5 | < 0.02 | < 0.02 | < 0.02 | 6.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 999.6 | 192.53 | 34.438 | 29.89 | 5.50 | 2.07 | < 0.02 | < 0.02 | 35.10 |
2020 | 1203.8 | 174.76 | 34.487 | 33.02 | 4.26 | 2.31 | < 0.02 | < 0.02 | 60.32 |
2021 | 1203.8 | < 0.02 | < 0.02 | < 0.02 | 4.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 1402.2 | 157.34 | 34.550 | 35.20 | 3.40 | 2.48 | < 0.02 | < 0.02 | 84.79 |
2017 | 1601.1 | 152.83 | 34.574 | 35.75 | 3.12 | 2.53 | < 0.02 | < 0.02 | 93.37 |
2018 | 1601.1 | < 0.02 | < 0.02 | < 0.02 | 3.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 1799.6 | 152.79 | 34.605 | 35.89 | 2.81 | 2.54 | < 0.02 | < 0.02 | 99.48 |
1214 | 1996.9 | 162.07 | 34.647 | 35.15 | 2.46 | 2.48 | < 0.02 | < 0.02 | 100.19 |
2015 | 1997 | < 0.02 | < 0.02 | < 0.02 | 2.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 2299.4 | 177.26 | 34.691 | 33.76 | 2.17 | 2.37 | < 0.02 | < 0.02 | 96.29 |
2011 | 2600.5 | 185.52 | 34.713 | 33.14 | 1.94 | 2.32 | < 0.02 | < 0.02 | 99.68 |
2012 | 2600.5 | < 0.02 | < 0.02 | < 0.02 | 1.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 2900.4 | 191.15 | 34.722 | 32.97 | 1.72 | 2.31 | < 0.02 | < 0.02 | 104.83 |
2008 | 3198.6 | 196.20 | 34.722 | 33.05 | 1.46 | 2.32 | < 0.02 | < 0.02 | 111.42 |
2009 | 3198.7 | < 0.02 | < 0.02 | < 0.02 | 1.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 3499.5 | 200.26 | 34.720 | 33.19 | 1.28 | 2.33 | < 0.02 | < 0.02 | 116.28 |
2005 | 3800.7 | 200.93 | 34.717 | 33.31 | 1.20 | 2.34 | < 0.02 | < 0.02 | 118.75 |
2006 | 3800.8 | < 0.02 | < 0.02 | < 0.02 | 1.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 4100.5 | 201.29 | 34.716 | 33.35 | 1.19 | 2.34 | < 0.02 | < 0.02 | 120.20 |
12003 | 4500.9 | < 0.02 | < 0.02 | < 0.02 | 1.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12002 | 4501 | 201.33 | 34.716 | 33.40 | 1.20 | 2.34 | < 0.02 | < 0.02 | 120.98 |
12001 | 4842.5 | 201.60 | 34.714 | 33.41 | 1.24 | 2.34 | < 0.02 | < 0.02 | 121.12 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |