Deployment Details
Survey: - IN2018_V03 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70111,Oxygen CTD 24 - SN 3534,Pressure CTD 24,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2018-04-19 16:58 to 2018-04-19 20:54 UTC
Where: 27° 06.0' S 155° 17.5' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2036 | 11.3 | < 0.02 | < 0.02 | < 0.02 | 24.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2035 | 11.5 | 215.58 | 35.676 | 0.03 | 24.47 | 0.05 | < 0.02 | < 0.02 | 0.32 |
2034 | 49.3 | 216.87 | 35.717 | 0.03 | 24.31 | 0.06 | < 0.02 | < 0.02 | 0.29 |
2033 | 112.5 | < 0.02 | < 0.02 | < 0.02 | 20.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
32 | 150.5 | 197.18 | 35.728 | 3.88 | 19.61 | 0.36 | < 0.02 | 0.02 | 0.97 |
2031 | 249.9 | 201.11 | 35.642 | 5.00 | 18.06 | 0.44 | < 0.02 | < 0.02 | 1.33 |
2030 | 282.1 | < 0.02 | < 0.02 | < 0.02 | 17.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 350.1 | 195.35 | 35.360 | 9.16 | 15.56 | 0.71 | < 0.02 | < 0.02 | 2.83 |
2028 | 448.7 | 190.84 | 35.021 | 14.52 | 12.70 | 1.06 | < 0.02 | < 0.02 | 5.22 |
2027 | 455.1 | < 0.02 | < 0.02 | < 0.02 | 12.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 599.9 | 206.29 | 34.667 | 20.32 | 9.31 | 1.43 | < 0.02 | < 0.02 | 8.62 |
2025 | 747.3 | 210.53 | 34.485 | 24.79 | 7.26 | 1.73 | < 0.02 | < 0.02 | 15.22 |
2024 | 753.9 | < 0.02 | < 0.02 | < 0.02 | 7.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 899.4 | 203.03 | 34.433 | 28.09 | 6.05 | 1.97 | < 0.02 | < 0.02 | 25.92 |
2021 | 1051.3 | < 0.02 | < 0.02 | < 0.02 | 4.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 1051.4 | 188.42 | 34.452 | 31.01 | 5.01 | 2.19 | < 0.02 | < 0.02 | 43.97 |
2020 | 1251.1 | 164.98 | 34.538 | 34.42 | 4.08 | 2.46 | < 0.02 | < 0.02 | 78.09 |
2018 | 1449.6 | < 0.02 | < 0.02 | < 0.02 | 3.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 1449.7 | 158.81 | 34.548 | 35.03 | 3.44 | 2.52 | < 0.02 | < 0.02 | 83.74 |
2017 | 1651 | 151.98 | 34.589 | 35.91 | 2.97 | 2.58 | < 0.02 | < 0.02 | 97.77 |
2015 | 1849.8 | < 0.02 | < 0.02 | < 0.02 | 2.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 1849.9 | 154.75 | 34.623 | 35.84 | 2.62 | 2.58 | < 0.02 | < 0.02 | 103.44 |
1214 | 2050.5 | 164.35 | 34.656 | 35.04 | 2.38 | 2.51 | < 0.02 | < 0.02 | 101.43 |
2012 | 2300.1 | < 0.02 | < 0.02 | < 0.02 | 2.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 2300.2 | 175.52 | 34.687 | 33.99 | 2.16 | 2.42 | < 0.02 | < 0.02 | 99.03 |
2011 | 2599.8 | 186.28 | 34.714 | 33.17 | 1.91 | 2.36 | < 0.02 | < 0.02 | 100.57 |
2009 | 2891.9 | < 0.02 | < 0.02 | < 0.02 | 1.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2010 | 2892 | 193.43 | 34.724 | 32.97 | 1.65 | 2.34 | < 0.02 | < 0.02 | 106.46 |
2008 | 3198.5 | 198.21 | 34.722 | 33.04 | 1.40 | 2.35 | < 0.02 | < 0.02 | 112.79 |
2006 | 3500.4 | < 0.02 | < 0.02 | < 0.02 | 1.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 3500.5 | 200.39 | 34.719 | 33.24 | 1.24 | 2.36 | < 0.02 | < 0.02 | 117.30 |
2005 | 3801.2 | 201.29 | 34.717 | 33.31 | 1.20 | 2.37 | < 0.02 | < 0.02 | 119.15 |
12003 | 4148.5 | < 0.02 | < 0.02 | < 0.02 | 1.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 4148.6 | 202.36 | 34.719 | 33.37 | 1.19 | 2.38 | < 0.02 | < 0.02 | 120.52 |
12002 | 4499.4 | 201.82 | 34.715 | 33.45 | 1.20 | 2.38 | < 0.02 | < 0.02 | 121.29 |
12001 | 4850.7 | 202.27 | 34.714 | 33.44 | 1.23 | 2.39 | < 0.02 | < 0.02 | 121.57 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24 - SN 3534 | Seabird | SBE43 | 3534 | Oxygen (µM) |
Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |