Deployment Details
Survey: - IN2017_T02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 8
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3154,Pressure CTD 22,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2017-11-18 00:03 to 2017-11-18 01:05 UTC
Where: 34° 34.7' S 120° 13.4' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1052 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 17.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1064 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 17.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1062 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 17.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1066 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 17.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1024 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 17.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1016 | 4.7 | < 0.02 | < 0.02 | 0.03 | 17.72 | 0.09 | 0.03 | < 0.02 | 0.77 |
1023 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 17.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1042 | 5 | < 0.02 | < 0.02 | < 0.02 | 17.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1022 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 17.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1015 | 40.8 | < 0.02 | < 0.02 | 0.03 | 17.38 | 0.09 | < 0.02 | < 0.02 | 0.76 |
1055 | 69.7 | < 0.02 | < 0.02 | 0.37 | 16.20 | 0.14 | 0.05 | 0.16 | 0.88 |
1059 | 69.9 | < 0.02 | < 0.02 | < 0.02 | 16.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1063 | 100.3 | < 0.02 | < 0.02 | 0.57 | 15.98 | 0.15 | 0.12 | 0.24 | 0.81 |
1071 | 200.4 | < 0.02 | < 0.02 | 1.00 | 14.44 | 0.24 | 0.45 | 0.14 | 0.26 |
1010 | 299.4 | < 0.02 | < 0.02 | < 0.02 | 12.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1054 | 400.4 | < 0.02 | < 0.02 | 12.78 | 10.49 | 0.94 | < 0.02 | 0.02 | 2.29 |
1008 | 500.2 | < 0.02 | < 0.02 | 15.01 | 9.79 | 1.08 | < 0.02 | < 0.02 | 3.19 |
1007 | 599.7 | < 0.02 | < 0.02 | 17.64 | 9.11 | 1.24 | < 0.02 | 0.02 | 4.73 |
1006 | 699.5 | < 0.02 | < 0.02 | 26.50 | 6.94 | 1.81 | 0.02 | < 0.02 | 16.81 |
1001 | 799.1 | < 0.02 | < 0.02 | 29.51 | 5.73 | 2.01 | 0.02 | < 0.02 | 25.52 |
1204 | 898.9 | < 0.02 | < 0.02 | 32.55 | 4.40 | 2.23 | < 0.02 | < 0.02 | 40.61 |
1203 | 999.8 | 185.61 | 34.423 | 33.96 | 3.74 | 2.35 | < 0.02 | < 0.02 | 50.89 |
1202 | 1087.1 | < 0.02 | < 0.02 | < 0.02 | 3.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2007 | 1087.5 | 183.33 | 34.433 | 34.24 | 3.62 | 2.38 | 0.02 | < 0.02 | 53.36 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3154 | Seabird | SBE 43 | 3154 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |