Deployment Details
Survey: - IN2017_T02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 2
Gear: Autosal Salinometer,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 24 - SN 4685,Licor - CTD 24 - SN 70111,Oxygen CTD 24-SBE 43-SN 3154,Pressure CTD 22,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer - CTD 24 -CST-1421DR
When: 2017-11-16 03:07 to 2017-11-16 04:03 UTC
Where: 34° 48.9' S 119° 29.9' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1062 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 17.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1042 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1022 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 17.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1024 | 6.2 | 245.77 | 35.740 | 0.04 | 17.57 | 0.09 | < 0.02 | < 0.02 | 1.54 |
1015 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 17.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1064 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 17.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1023 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 17.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1052 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 17.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1016 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 17.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1066 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 17.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1059 | 30.4 | < 0.02 | < 0.02 | 0.03 | 17.53 | 0.08 | < 0.02 | < 0.02 | 1.52 |
1063 | 60.4 | < 0.02 | < 0.02 | 0.16 | 16.83 | 0.12 | < 0.02 | 0.09 | 1.36 |
1055 | 60.5 | < 0.02 | < 0.02 | < 0.02 | 16.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1071 | 99.2 | < 0.02 | < 0.02 | 0.44 | 16.22 | 0.15 | 0.07 | 0.18 | 1.24 |
1010 | 200.9 | < 0.02 | < 0.02 | 1.60 | 14.64 | 0.25 | < 0.02 | 0.22 | 0.79 |
1054 | 300.5 | 253.76 | 35.071 | 7.04 | 12.09 | 0.61 | < 0.02 | 0.02 | 1.12 |
1008 | 401.1 | < 0.02 | < 0.02 | < 0.02 | 10.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1007 | 501.3 | < 0.02 | < 0.02 | 16.55 | 9.29 | 1.16 | < 0.02 | < 0.02 | 3.91 |
1006 | 600.1 | < 0.02 | < 0.02 | 20.40 | 8.57 | 1.40 | < 0.02 | < 0.02 | 6.89 |
1001 | 699.9 | 182.62 | 34.465 | 26.58 | 6.98 | 1.81 | < 0.02 | < 0.02 | 17.03 |
1204 | 800.5 | < 0.02 | < 0.02 | 30.55 | 5.35 | 2.08 | < 0.02 | < 0.02 | 29.88 |
1203 | 901.1 | < 0.02 | < 0.02 | 32.53 | 4.40 | 2.23 | < 0.02 | < 0.02 | 40.74 |
1202 | 985.1 | < 0.02 | < 0.02 | < 0.02 | 3.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2007 | 985.2 | 188.56 | 34.409 | 33.69 | 3.89 | 2.32 | < 0.02 | < 0.02 | 48.39 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 24-SBE 43-SN 3154 | Seabird | SBE 43 | 3154 | Oxygen (µM) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |