Deployment Details
Survey: - IN2017_T02 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CTD 20 - SN 1312,CTD 23 - SN 1312,CTD 24 - SN 1332,Chelsea Tech Fluorometer,Conductivity CTD 21 - SN 3868,Conductivity CTD 24 - SN 4685,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70111,Licor - CTD 24 - SN 70111,Oxygen CTD 21-SBE 43-SN 3159,Oxygen CTD 24-SBE 43-SN 3154,Pressure CTD 21,Pressure CTD 22,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20 - SN 6189,Temperature CTD 21 - SN 6189,Temperature CTD 24 - SN 4522,Transmissometer,Transmissometer - CTD 24 -CST-1421DR
When: 2017-11-15 19:37 to 2017-11-15 20:30 UTC
Where: 34° 53.9' S 119° 41.9' E
Maximum Depth (m): unknown
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
1024 | 9.4 | < 0.02 | < 0.02 | 0.03 | 17.19 | 0.11 | < 0.02 | < 0.02 | 1.55 |
1023 | 51.1 | < 0.02 | < 0.02 | 0.03 | 16.32 | 0.12 | < 0.02 | < 0.02 | 1.33 |
1022 | 71.6 | < 0.02 | < 0.02 | < 0.02 | 15.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1042 | 80.4 | < 0.02 | < 0.02 | 0.32 | 15.16 | 0.18 | < 0.02 | 0.13 | 1.06 |
1066 | 91.2 | < 0.02 | < 0.02 | 1.16 | 14.89 | 0.22 | < 0.02 | 0.36 | 1.04 |
1052 | 105.9 | 251.04 | < 0.02 | 1.66 | 14.64 | 0.25 | < 0.02 | 0.21 | 1.01 |
1062 | 203.1 | 253.27 | < 0.02 | 5.32 | 12.76 | 0.50 | < 0.02 | 0.02 | 1.12 |
1064 | 305.7 | < 0.02 | < 0.02 | < 0.02 | 11.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1016 | 401.9 | < 0.02 | < 0.02 | 14.31 | 10.01 | 1.03 | < 0.02 | < 0.02 | 3.40 |
1015 | 501.6 | 246.84 | < 0.02 | 16.49 | 9.38 | 1.17 | < 0.02 | < 0.02 | 4.33 |
1059 | 606.5 | 235.41 | < 0.02 | 19.70 | 8.67 | 1.36 | < 0.02 | < 0.02 | 6.60 |
1055 | 704.8 | < 0.02 | < 0.02 | 25.11 | 7.45 | 1.71 | < 0.02 | < 0.02 | 13.93 |
1063 | 803.3 | < 0.02 | < 0.02 | 28.37 | 6.22 | 1.93 | < 0.02 | < 0.02 | 22.28 |
1071 | 899.9 | < 0.02 | < 0.02 | 31.48 | 4.84 | 2.16 | < 0.02 | < 0.02 | 34.63 |
1204 | 1000 | < 0.02 | < 0.02 | < 0.02 | 4.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2007 | 1000.4 | 191.69 | 34.395 | 33.14 | 4.09 | 2.29 | < 0.02 | < 0.02 | 44.76 |
1007 | 1000.6 | 191.77 | < 0.02 | < 0.02 | 4.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1054 | 1000.6 | 191.86 | 34.395 | < 0.02 | 4.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1203 | 1000.7 | 191.60 | 34.395 | < 0.02 | 4.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1008 | 1000.8 | < 0.02 | < 0.02 | < 0.02 | 4.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1006 | 1000.8 | 191.73 | 34.395 | < 0.02 | 4.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1001 | 1000.8 | 191.91 | 34.395 | < 0.02 | 4.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1202 | 1000.9 | < 0.02 | < 0.02 | < 0.02 | 4.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1010 | 1001 | 191.95 | 34.395 | < 0.02 | 4.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
CTD 20 - SN 1312 | Seabird | SBE9+ V_2 | 1312 | |
CTD 23 - SN 1312 | Seabird | SBE911 | 1312 | |
CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 21 - SN 3868 | Seabird | SBE4C | 3868 | |
Conductivity CTD 24 - SN 4685 | Seabird | SBE4C | 4685 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen CTD 21-SBE 43-SN 3159 | Seabird | SBE 43 | 3159 | Oxygen (µM) |
Oxygen CTD 24-SBE 43-SN 3154 | Seabird | SBE 43 | 3154 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 858 | Pressure (decibars) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 21 - SN 6189 | Seabird | SBE3T | 6189 | Temperature (deg C) |
Temperature CTD 24 - SN 4522 | Sea-Bird Electronics Inc | SBE3T | 4522 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) | ||
Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |