Please login if you have access to particular applications.
Deployment Details
Survey: - IN2017_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 65
Operation No.: 520
Gear: Autosal Salinometer,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Seabird SBE-32,Temperature CTD 22-SN 2751,Transmissometer
When: 2017-11-03 01:59 to 2017-11-03 02:25 UTC
Where: 20° 07.3' S 116° 07.5' E
Maximum Depth (m): 55.5
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
30 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 25.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 25.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 25.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 25.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 25.78 | 0.11 | < 0.02 | < 0.02 | 4.52 |
2031 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 25.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 25.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2032 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 25.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 25.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 25.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 25.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 25.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 25.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 25.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 25.75 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 25.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 25.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 25.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 25.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 25.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 3.3 | < 0.02 | < 0.02 | < 0.02 | 25.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 3.4 | < 0.02 | < 0.02 | < 0.02 | 25.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 10.1 | < 0.02 | < 0.02 | < 0.02 | 25.52 | 0.11 | < 0.02 | < 0.02 | 4.61 |
2011 | 10.3 | < 0.02 | < 0.02 | < 0.02 | 25.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 10.3 | < 0.02 | < 0.02 | < 0.02 | 25.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 10.4 | < 0.02 | < 0.02 | < 0.02 | 25.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 24.9 | < 0.02 | < 0.02 | < 0.02 | 25.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 25 | < 0.02 | < 0.02 | < 0.02 | 25.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 25 | < 0.02 | < 0.02 | 0.03 | 25.02 | 0.12 | < 0.02 | 0.02 | 4.61 |
6 | 25.1 | < 0.02 | < 0.02 | < 0.02 | 25.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 55.4 | < 0.02 | < 0.02 | < 0.02 | 24.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 55.4 | < 0.02 | < 0.02 | < 0.02 | 24.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12001 | 55.5 | 204.10 | 35.023 | 0.29 | 24.58 | 0.16 | 0.05 | 0.21 | 5.57 |
12002 | 55.5 | < 0.02 | < 0.02 | < 0.02 | 24.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |