Deployment Details
Survey: - IN2017_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 60
Operation No.: 468
Gear: Autosal Salinometer,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Seabird SBE-32,Temperature CTD 22-SN 2751,Transmissometer
When: 2017-11-01 05:13 to 2017-11-01 05:37 UTC
Where: 19° 56.1' S 115° 44.6' E
Maximum Depth (m): 76.3
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 18 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 25.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 25.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2025 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2019 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2029 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2020 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2021 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2026 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2028 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2027 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2017 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.52 | 0.09 | < 0.02 | < 0.02 | 3.26 |
| 2031 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 25.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2034 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 25.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2023 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 25.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2032 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 25.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2033 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 25.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2022 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 25.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2013 | 10.4 | 213.52 | 34.859 | < 0.02 | 25.45 | 0.10 | < 0.02 | < 0.02 | 3.29 |
| 1214 | 10.5 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2015 | 10.7 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2016 | 10.7 | < 0.02 | < 0.02 | < 0.02 | 25.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 24.2 | < 0.02 | < 0.02 | < 0.02 | 25.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2011 | 24.3 | < 0.02 | < 0.02 | < 0.02 | 25.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2009 | 24.5 | < 0.02 | < 0.02 | < 0.02 | 25.12 | 0.10 | < 0.02 | < 0.02 | 3.58 |
| 2036 | 24.5 | < 0.02 | < 0.02 | < 0.02 | 25.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 64.4 | < 0.02 | < 0.02 | < 0.02 | 24.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1201 | 64.5 | < 0.02 | < 0.02 | < 0.02 | 24.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2008 | 64.7 | < 0.02 | < 0.02 | < 0.02 | 24.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2005 | 64.8 | < 0.02 | < 0.02 | 0.48 | 24.49 | 0.17 | < 0.02 | 0.16 | 4.76 |
| 12004 | 76.2 | < 0.02 | < 0.02 | < 0.02 | 24.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12001 | 76.3 | 197.00 | 34.989 | 1.29 | 24.28 | 0.23 | < 0.02 | 0.29 | 5.40 |
| 12002 | 76.3 | < 0.02 | < 0.02 | < 0.02 | 24.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12003 | 76.3 | < 0.02 | < 0.02 | < 0.02 | 24.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Seabird SBE-32 | Seabird | SBE-32 | 263 | |
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
| Transmissometer | SeaTech | Transmittance (%) |