Please login if you have access to particular applications.
Deployment Details
Survey: - IN2017_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 48
Operation No.: 374
Gear: Autosal Salinometer,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Seabird SBE-32,Temperature CTD 22-SN 2751,Transmissometer
When: 2017-10-28 05:06 to 2017-10-28 05:27 UTC
Where: 19° 28.6' S 116° 41.0' E
Maximum Depth (m): 71.4
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2023 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 26.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 4 | < 0.02 | < 0.02 | < 0.02 | 26.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 4 | < 0.02 | < 0.02 | < 0.02 | 25.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 4.1 | < 0.02 | < 0.02 | 0.02 | 26.04 | 0.09 | < 0.02 | < 0.02 | 3.01 |
2032 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 25.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 25.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2034 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 25.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 26.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2020 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 26.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 26.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2026 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 26.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 26.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 25.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 10.3 | < 0.02 | < 0.02 | < 0.02 | 25.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1214 | 10.3 | < 0.02 | < 0.02 | < 0.02 | 25.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 10.5 | 211.69 | 34.897 | 0.02 | 25.80 | 0.09 | < 0.02 | < 0.02 | 2.99 |
2009 | 25.5 | < 0.02 | < 0.02 | 0.02 | 25.77 | 0.09 | < 0.02 | < 0.02 | 3.01 |
2036 | 25.5 | < 0.02 | < 0.02 | < 0.02 | 25.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 25.6 | < 0.02 | < 0.02 | < 0.02 | 25.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2011 | 25.7 | < 0.02 | < 0.02 | < 0.02 | 25.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 58.6 | < 0.02 | < 0.02 | < 0.02 | 24.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 58.6 | < 0.02 | < 0.02 | < 0.02 | 24.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 58.7 | < 0.02 | < 0.02 | 2.07 | 24.36 | 0.27 | < 0.02 | 0.15 | 5.67 |
6 | 58.7 | < 0.02 | < 0.02 | < 0.02 | 24.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12003 | 71.2 | < 0.02 | < 0.02 | < 0.02 | 23.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12004 | 71.3 | < 0.02 | < 0.02 | < 0.02 | 23.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12001 | 71.3 | 180.03 | 35.027 | 3.88 | 23.48 | 0.39 | < 0.02 | 0.15 | 7.79 |
12002 | 71.4 | < 0.02 | < 0.02 | < 0.02 | 23.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |