Deployment Details
Survey: - IN2017_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 24
Operation No.: 175
Gear: Autosal Salinometer,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Seabird SBE-32,Temperature CTD 22-SN 2751,Transmissometer
When: 2017-10-20 04:14 to 2017-10-20 04:29 UTC
Where: 20° 19.7' S 117° 14.5' E
Maximum Depth (m): 27.6
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 2021 | 2.6 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2028 | 2.6 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2029 | 2.7 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1214 | 2.7 | < 0.02 | < 0.02 | < 0.02 | 24.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2020 | 2.7 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2013 | 2.7 | < 0.02 | < 0.02 | < 0.02 | 24.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2027 | 2.7 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 2.8 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 2.8 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2026 | 2.8 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2009 | 2.8 | < 0.02 | < 0.02 | < 0.02 | 24.65 | 0.14 | < 0.02 | < 0.02 | 3.89 |
| 2015 | 2.8 | < 0.02 | < 0.02 | < 0.02 | 24.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2032 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2033 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2031 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2034 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2022 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2019 | 2.9 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2016 | 3 | < 0.02 | < 0.02 | < 0.02 | 24.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2011 | 3 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 3 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2025 | 3 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 3 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2023 | 3 | < 0.02 | < 0.02 | < 0.02 | 24.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2036 | 3 | < 0.02 | < 0.02 | < 0.02 | 24.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2017 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 24.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 10 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2005 | 10.1 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2008 | 10.1 | < 0.02 | < 0.02 | < 0.02 | 24.61 | 0.14 | < 0.02 | < 0.02 | 3.91 |
| 1201 | 10.1 | < 0.02 | < 0.02 | < 0.02 | 24.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12003 | 27.4 | < 0.02 | < 0.02 | < 0.02 | 24.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12004 | 27.4 | < 0.02 | < 0.02 | < 0.02 | 24.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12002 | 27.5 | < 0.02 | < 0.02 | < 0.02 | 24.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12001 | 27.6 | 213.75 | 35.427 | < 0.02 | 24.58 | 0.14 | < 0.02 | < 0.02 | 3.91 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
| Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
| Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Seabird SBE-32 | Seabird | SBE-32 | 263 | |
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
| Transmissometer | SeaTech | Transmittance (%) |