Deployment Details
Survey: - IN2017_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Operation No.: 86
When: 2017-10-16 02:11 to 2017-10-16 02:32 UTC
Where: 19° 19.6' S 117° 34.9' E
Maximum Depth (m): 90.7
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|---|
2034 | 4 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2031 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2025 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2027 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2023 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2029 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2021 | 4.4 | < 0.02 | < 0.02 | 0.03 | 25.24 | 0.11 | < 0.02 | < 0.02 | 3.33 |
2026 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2022 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2028 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
30 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
24 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2032 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2033 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 25.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2017 | 10.1 | < 0.02 | < 0.02 | 0.02 | 25.25 | 0.11 | < 0.02 | < 0.02 | 3.37 |
2020 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 25.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
18 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 25.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2019 | 10.3 | < 0.02 | < 0.02 | < 0.02 | 25.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2016 | 25.2 | < 0.02 | < 0.02 | < 0.02 | 25.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2013 | 25.3 | < 0.02 | < 0.02 | 0.03 | 25.22 | 0.11 | < 0.02 | 0.02 | 3.43 |
1214 | 25.5 | < 0.02 | < 0.02 | < 0.02 | 25.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2015 | 25.5 | < 0.02 | < 0.02 | < 0.02 | 25.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2009 | 50.3 | < 0.02 | < 0.02 | 0.49 | 24.90 | 0.16 | < 0.02 | 0.14 | 4.20 |
2011 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2036 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2008 | 75.8 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
6 | 75.9 | < 0.02 | < 0.02 | < 0.02 | 24.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
1201 | 76 | < 0.02 | < 0.02 | < 0.02 | 24.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
2005 | 76 | 197.13 | 35.126 | 1.36 | 24.63 | 0.24 | < 0.02 | 0.23 | 5.38 |
12003 | 90.4 | < 0.02 | < 0.02 | < 0.02 | 24.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12002 | 90.5 | < 0.02 | < 0.02 | < 0.02 | 24.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
12001 | 90.5 | 189.72 | 35.100 | 2.24 | 24.29 | 0.30 | < 0.02 | 0.20 | 6.32 |
12004 | 90.7 | < 0.02 | < 0.02 | < 0.02 | 24.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) |
Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) |
Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) |
Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Seabird SBE-32 | Seabird | SBE-32 | 263 | |
Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer | SeaTech | Transmittance (%) |