Deployment Details
Survey: - IN2017_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 7
Operation No.: 61
Gear: Autosal Salinometer,Chelsea Tech Fluorometer,Conductivity CTD 22-SN 3908,Licor - LI-190SL Q46071,Pressure CTD 22,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Seabird SBE-32,Temperature CTD 22-SN 2751,Transmissometer
When: 2017-10-15 02:31 to 2017-10-15 02:49 UTC
Where: 19° 51.8' S 117° 41.9' E
Maximum Depth (m): 49.6
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number | Pressure | Oxygen (µM) | Salinity (psu) | Nitrate (µM) | Temperature (deg C) | Orthophosphate (µM) | Ammonia (µM) | Nitrite (µM) | Silicate (µM) | 
|---|---|---|---|---|---|---|---|---|---|
| 30 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2020 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2017 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2021 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2013 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 24.89 | 0.17 | < 0.02 | < 0.02 | 3.40 | 
| 24 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2022 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2031 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2015 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 24.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 18 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2016 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2029 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2033 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2025 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2034 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2026 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2028 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2027 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2019 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2023 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1214 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 24.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2032 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 12 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 24.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2009 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 24.89 | 0.17 | < 0.02 | < 0.02 | 3.37 | 
| 2036 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 24.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2011 | 10.7 | < 0.02 | < 0.02 | < 0.02 | 24.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2008 | 24.7 | < 0.02 | < 0.02 | < 0.02 | 24.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 1201 | 24.8 | < 0.02 | < 0.02 | < 0.02 | 24.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 2005 | 24.8 | < 0.02 | < 0.02 | < 0.02 | 24.79 | 0.17 | < 0.02 | < 0.02 | 3.39 | 
| 6 | 24.8 | < 0.02 | < 0.02 | < 0.02 | 24.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 12001 | 49.5 | 207.72 | 35.215 | 0.05 | 24.74 | 0.19 | 0.09 | < 0.02 | 3.88 | 
| 12004 | 49.5 | < 0.02 | < 0.02 | < 0.02 | 24.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 12002 | 49.5 | < 0.02 | < 0.02 | < 0.02 | 24.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
| 12003 | 49.6 | < 0.02 | < 0.02 | < 0.02 | 24.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 | 
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring | 
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 71611 | Salinity (psu) | 
| Chelsea Tech Fluorometer | Chelsea Tech | Fluorometer | 65941001 | Fluorescence (arbitrary units) | 
| Conductivity CTD 22-SN 3908 | Seabird | SBE4C | 3908 | |
| Licor - LI-190SL Q46071 | LiCor | LI-190SL | Q46071 | PAR (uE/m**2/sec) | 
| Pressure CTD 22 | Digiquartz | 410K-134 | 1243 | Pressure (decibars) | 
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrite (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
| Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| Seabird SBE-32 | Seabird | SBE-32 | 263 | |
| Temperature CTD 22-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) | 
| Transmissometer | SeaTech | Transmittance (%) |