Deployment Details
Survey: - SS2010_V05 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 43
Operation No.: 1
Gear: Altitude CTD 21-41023,CTD 21,Conductivity CTD 21-SN 2312,Fluorometer-CTD 21 -Chelsea-06-5941-001,Licor - CTD 21 - SN 70111,Nitrate - CTD21 Satlantic ISUS V3-076,Oxygen CTD 21-SBE 43-SN 1794,Pressure CTD 21,Temperature CTD 21 - SN 4718,Transmissometer - CTD 21 -CST-1016DR
When: 2010-07-25 01:16 to 2010-07-25 02:00 UTC
Where:
32° 00.2' S
114° 00.0' E
to
32° 00.6' S
114° 00.3' E
Maximum Depth (m): 988
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|
1070 | 2.7 | 235.00 | 35.716 | < 0.02 | 0.10 | 0.04 | 2.34 |
1052 | 17.9 | < 0.02 | 0.08 | < 0.02 | 2.33 | ||
1064 | 36.3 | < 0.02 | 0.08 | 0.03 | 2.33 | ||
1062 | 63.6 | 0.13 | 0.10 | 0.03 | 2.18 | ||
1060 | 75.9 | 0.23 | 0.11 | 0.04 | 2.15 | ||
1067 | 94.3 | 0.40 | 0.12 | 0.03 | 2.08 | ||
1054 | 141.9 | 234.55 | 35.552 | 2.61 | 0.32 | 0.02 | 1.53 |
1057 | 195 | 5.13 | 0.47 | 0.02 | 1.64 | ||
1024 | 490.8 | 20.04 | 1.23 | 0.02 | 5.02 | ||
1068 | 985.1 | 165.51 | 34.469 | 34.73 | 2.46 | < 0.02 | 60.71 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Altitude CTD 21-41023 | PSA | 916T | 41023 | Altitude(m) |
CTD 21 | Seabird | SBE9plus | 09P44558-0858 | |
Conductivity CTD 21-SN 2312 | Seabird | SBE-4 | 2312 | |
Fluorometer-CTD 21 -Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 21 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Nitrate - CTD21 Satlantic ISUS V3-076 | Satlantic | V3 | 076 | Nitrate (µM) |
Oxygen CTD 21-SBE 43-SN 1794 | Seabird | SBE 43 | 1794 | Oxygen (µM) |
Pressure CTD 21 | Digiquartz | 410K-134 | 101526 | Pressure (decibars) |
Temperature CTD 21 - SN 4718 | Seabird | SBE3plus | 4718 | Temperature (deg C) |
Transmissometer - CTD 21 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |